• 제목/요약/키워드: Structural response analysis

검색결과 2,908건 처리시간 0.032초

송전철탑의 탄성계수의 변이에 따른 확률적 응답변이도 (Stochastic Response Analysis of Transmission Tower Subjected to Young's Modulus Variation)

  • 동원영;정영수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.207-215
    • /
    • 1993
  • With the aid of finite element method, this paper deals with the problem of structural response variability of transmission tower subjected to the spatial variability of material properties, Young's modulus herein. The spatial variability of material property are modeled as two-dimensional stochastic field which has an isotropic auto-correlation function. Response variability has been computed based on two numerical techniques, such as the Neumann expansion method in conjunction with the Monte Carlo simulation method. The results by these numerical methods are compared with those by the deterministic approach.

  • PDF

Seismic response analysis of reinforced concrete frames including soil flexibility

  • Jayalekshmi, B.R.;Poojary, V.G. Deepthi;Venkataramana, Katta;Shivashankar, R.
    • Structural Engineering and Mechanics
    • /
    • 제48권1호
    • /
    • pp.1-16
    • /
    • 2013
  • The seismic response of RC space frame structures with isolated footing resting on a shallow soil stratum on rock is presented in this paper. Homogeneous soil stratum of different stiffness in the very soft to stiff range is considered. Soil, footing and super structure are considered to be the parts of an integral system. A finite element model of the integrated system is developed and subjected to scaled acceleration time histories recorded during two different real earthquakes. Dynamic analysis is performed using mode superposition method of transient analysis. A parametric study is conducted to investigate the effect of flexibility of soil in the dynamic behaviour of low-rise building frames. The time histories and Fourier spectra of roof displacement, base shear and structural response quantities of the space frame on compliant base are presented and compared with the fixed base condition. Results indicate that the incorporation of soil flexibility is required for the realistic estimate of structural seismic response especially for single storey structures resting on very soft soil.

비구조요소의 내진 설계를 위한 기존 층응답스펙트럼의 평가 (A Study on Evaluation of Floor Response Spectrum for Seismic Design of Non-Structural Components)

  • 최경석;이원호;양원직;김형준
    • 한국지진공학회논문집
    • /
    • 제17권6호
    • /
    • pp.279-291
    • /
    • 2013
  • The seismic damage of non-structural components, such as communication facilities, causes direct economic losses as well as indirect losses which result from social chaos occurring with downtime of communication and financial management network systems. The current Korean seismic code, KBC2009, prescribes the design criteria and requirements of non-structural components based on their elastic response. However, it is difficult for KBC to reflect the dynamic characteristics of structures where non-structural components exist. In this study, both linear and nonlinear time history analyses of structures with various analysis parameters were carried out and floor acceleration spectra obtained from analyses were compared with both ground acceleration spectra used for input records of the analyses and the design floor acceleration spectrum proposed by National Radio Research Agency. Also, this study investigates to find out the influence of structural dynamic characteristics on the floor acceleration spectra. The analysis results show that the acceleration amplification is observed due to the resonance phenomenon and such amplification increases with the increase of building heights and with the decrease of structure's energy dissipation capacities.

확률변수의 상관성을 고려한 사장교의 신뢰성해석 (The Reliability Analysis of the Cable Stayed Bridge Considered to Correlation of the Random Variable)

  • 한성호;권의성;정인수;신재철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.210-217
    • /
    • 2004
  • Developed is the new program that the reliability analysis can be performed more effectively considering the correlation of structural members about the cable stayed bridge. This program is formulated the stochastic finite element method suitable for the reliability analysis and the new safety evaluation method is proposed which is different from the existing one by the deterministic method or MCS response analysis. After conducting the initial equilibrium analysis of cable stayed bridges, the stochastic finite element is formulated through the perturbation method and the reliability analysis considering the correlation of stochastic variables is conducted. The results in various types of cable stayed bridge show that the probability of failure considering the correlation is larger than the non-correlation. The fan system is more stable than other systems at the structural response and the probability failure.

  • PDF

An improved response surface method for reliability analysis of structures

  • Basaga, Hasan Basri;Bayraktar, Alemdar;Kaymaz, Irfan
    • Structural Engineering and Mechanics
    • /
    • 제42권2호
    • /
    • pp.175-189
    • /
    • 2012
  • This paper presents an algorithm for structural reliability with the response surface method. For this aim, an approach with three stages is proposed named as improved response surface method. In the algorithm, firstly, a quadratic approximate function is formed and design point is determined with First Order Reliability Method. Secondly, a point close to the exact limit state function is searched using the design point. Lastly, vector projected method is used to generate the sample points and Second Order Reliability Method is performed to obtain reliability index and probability of failure. Five numerical examples are selected to illustrate the proposed algorithm. The limit state functions of three examples (cantilever beam, highly nonlinear limit state function and dynamic response of an oscillator) are defined explicitly and the others (frame and truss structures) are defined implicitly. ANSYS finite element program is utilized to obtain the response of the structures which are needed in the reliability analysis of implicit limit state functions. The results (reliability index, probability of failure and limit state function evaluations) obtained from the improved response surface are compared with those of Monte Carlo Simulation, First Order Reliability Method, Second Order Reliability Method and Classical Response Surface Method. According to the results, proposed algorithm gives better results for both reliability index and limit state function evaluations.

부분구조모델을 이용한 건축물의 국부진동해석에서의 오차원인 분석 (Error Estimate of Local Vibration for Building Structures Using Substructure Models)

  • 안상경;이현수;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2001
  • Analysis of a structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic response. Especially, when a structure is loaded with local vibration source, it may not be economical to model the whole structure to obtain the responses of specific members located near or far from the sources. In this study, substructure models have been used for analysis of local vibration An analysis of local vibration is performed for the case that the loaded point and the response point are located on the same floor. Other analysis is performed for the case that the loaded point and the response point are located on the different floor. In this case, if only the floors on which loaded and response points are located are modeled, response of substructure model is very different from that of full model. So, there should be a consideration that degrees of freedom of floors in addition to those of loaded and response floors are included to improve results of dynamic analysis. In this study, floors between loaded floor and response floor were modeled so that modeshapes which affect the response are presented well.

  • PDF

광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석 (Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor)

  • 김호선;장화섭;양동운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.35-43
    • /
    • 2012
  • 일반적으로 교량의 하중저항능력인 내하력은 교량의 거동에 큰 영향을 줄 수 있는 심각한 손상, 결함, 재료적인 열화현상이 존재하지 않는다면 이론적인 방법으로 평가한 내하력보다 여유가 있다. 그러나 현재 내하력을 구하기위한 재하실험 및 구조해석 과정에서 이미 오차가 포함되어 있어 응답보정계수의 신뢰성이 떨어지고 있다. 이에 본 연구에서는 센서의 센싱 문제와 구조해석 모델의 적정성에 오차를 해결하기 위하여 센서부에서 기존의 전기저항식 변형률, 변위 센서의 문제점을 도출하여 성능이 우수한 스마트 센서인 광섬유 스마트 센서로의 변화를 추진하고자 한다. 또한, 다양한 구조해석 모델 해석을 통하여 최적의 적정 모델을 선정함으로서 응답보정계수의 정확성을 향상시키고자 하였다.

Wind-induced response of structurally coupled twin tall buildings

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • 제10권4호
    • /
    • pp.383-398
    • /
    • 2007
  • The paper describes a study of the effects of structural coupling on the wind-induced response of twin tall buildings connected by a skybridge. Development of a dual high-frequency force balance used in wind tunnel investigation and background information on the methodology employed in analysis are presented. Comparisons of the wind-induced building response (rooftop acceleration) of structurally coupled and uncoupled twin buildings are provided and the influence of structural coupling is assessed. It is found that the adverse aerodynamic interference effects caused by close proximity of the buildings can be significantly reduced by the coupling. Neglecting of such interactions may lead to excessively conservative estimates of the wind-induced response of the buildings. The presented findings suggest that structural coupling should be included in wind-resistant design of twin tall buildings.

Investigations on seismic response of two span cable-stayed bridges

  • Bhagwat, Madhav;Sasmal, Saptarshi;Novak, B.;Upadhyay, A.
    • Earthquakes and Structures
    • /
    • 제2권4호
    • /
    • pp.337-356
    • /
    • 2011
  • In this paper, cable-stayed bridges with single pylon and two equal side spans, with variations in geometry and span ranging from 120 m to 240 m have been studied. 3D models of the bridges considered in this study have been analysed using ANSYS. As the first step towards a detailed seismic analysis, free vibration response of different geometries is studied for their mode shapes and frequencies. Typical pattern of free vibration responses in different frequencies with change in geometry is observed. Further, three different seismic loading histories are chosen with various characteristics to find the structural response of different geometries under seismic loading. Effect of variation in pylon shape, cable arrangement with variation in span is found to have typical characteristics with different structural response under seismic loading. From the study, it is observed that the structural response is very much dependent on the geometry of the cable-stayed bridge and the characteristics of the seismic loading as well. Further, structural responses obtained from the study would help the design engineers to take decisions on geometric shapes of the bridges to be constructed in seismic prone zones.

응답스펙트럼법을 이용한 지진하중을 받는 원전용 주냉각수펌프의 내진 건전성 평가 (Seismic Evaluation of Structural Integrity of Main Cooling-Water Pump by Response Spectrum Analysis)

  • 정철섭
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1773-1778
    • /
    • 2010
  • 본 논문은 원자력 내진등급 원전용 주냉각수 펌프의 지진하중에 대한 구조 건전성을 코드에 따라 평가하였다. 펌프 구조물을 3차원 모델링하여 유한요소법을 사용하여 모달 해석 및 응답스펙트럼 해석을 수행하였다. 모달 해석 결과 고유진동수, 모드형상 및 모드참여계수를 얻을 수 있었다. 응력해석에서 구한 응력들을 조합하여 원자력 규격집에서 제시한 허용응력과 비교하여 펌프의 구조 건전성을 판단하였다. 모든 지진하중에 대한 펌프 구조물에서의 응력은 허용값 보다 작게 분포하므로 구조적 건전성을 유지한다고 평가할 수 있다.