• 제목/요약/키워드: Structural concrete

검색결과 7,099건 처리시간 0.032초

비선형 유한요소해석을 이용한 PC 기둥-H 형강보의 구조거동 분석 (Evaluation of Structural Behavior of Precast-Concrete Column and H-Beam using Non-linear Finite Element Analysis)

  • 박정심;박순규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.425-428
    • /
    • 2004
  • Nonlinear finite element analysis is conducted to predict the structural behavior of precast concrete column and steel beam connected by using bolted connections. The Nonlinear FEM program is based on the modified compression field theory which has good accuracy in the concrete structures. The link element is properly used to model the discontinuity between precast concrete column and steel beam. Predictions from the proposed model are compared with experimental results and it is concluded that structural behaviors of the composite structures, such as strength capacity, crack pattern and failure mode, can be predicted quite successfully.

  • PDF

Polystyrene Beads를 이용한 경량콘크리트의 강도특성에 관한 실험적 연구 (An Experimental Study on Compressive Strength of Lightweight Concrete made of Polystyrene Foam Balls)

  • 이경동;한재익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.155-160
    • /
    • 1999
  • Recently, the study on mix design of lightweight concrete using the polystyrene foam balls is put into practice from the viewpoint to grade up the quality of concrete and recyclable usage of industrial by products. Polystyrene aggregate concrete, PAC, can be used as structural concrete in low strength application. For instance, PAC could be used in the middle part of sandwich panel where stresses are generally low and in the case of grid-type reinforcement where it does not need high bond strength but little compressive strength to resist the pressure of transverse reinforcement. From this point of view, the authors discussed the influence of fluidity and compressive strength of concrete by the difference of the volume percentage of polystyrene foam balls and water cement ratio.

  • PDF

Damage progression study in fibre reinforced concrete using acoustic emission technique

  • Banjara, Nawal Kishor;Sasmal, Saptarshi;Srinivas, V.
    • Smart Structures and Systems
    • /
    • 제23권2호
    • /
    • pp.173-184
    • /
    • 2019
  • The main objective of this study is to evaluate the true fracture energy and monitor the damage progression in steel fibre reinforced concrete (SFRC) specimens using acoustic emission (AE) features. Four point bending test is carried out using pre-notched plain and fibre reinforced (0.5% and 1% volume fraction) - concrete under monotonic loading. AE sensors are affixed at different locations of the specimens and AE parameters such as rise time, AE energy, hits, counts, amplitude and duration etc. are obtained. Using the captured and processed AE event data, fracture process zone is identified and the true fracture energy is evaluated. The AE data is also employed for tracing the damage progression in plain and fibre reinforced concrete, using both parametric- and signal- based techniques. Hilbert - Huang transform (HHT) is used in signal based processing for evaluating instantaneous frequency of the acoustic events. It is found that the appropriately processed and carefully analyzed acoustic data is capable of providing vital information on progression of damage on different types of concrete.

Transfer learning for crack detection in concrete structures: Evaluation of four models

  • Ali Bagheri;Mohammadreza Mosalmanyazdi;Hasanali Mosalmanyazdi
    • Structural Engineering and Mechanics
    • /
    • 제91권2호
    • /
    • pp.163-175
    • /
    • 2024
  • The objective of this research is to improve public safety in civil engineering by recognizing fractures in concrete structures quickly and correctly. The study offers a new crack detection method based on advanced image processing and machine learning techniques, specifically transfer learning with convolutional neural networks (CNNs). Four pre-trained models (VGG16, AlexNet, ResNet18, and DenseNet161) were fine-tuned to detect fractures in concrete surfaces. These models constantly produced accuracy rates greater than 80%, showing their ability to automate fracture identification and potentially reduce structural failure costs. Furthermore, the study expands its scope beyond crack detection to identify concrete health, using a dataset with a wide range of surface defects and anomalies including cracks. Notably, using VGG16, which was chosen as the most effective network architecture from the first phase, the study achieves excellent accuracy in classifying concrete health, demonstrating the model's satisfactorily performance even in more complex scenarios.

고강도 콘크리트를 사용한 저층형 내력벽의 강도 (Strength of Low Rise Structural Walls Using High Strength Concrete)

  • 윤현도;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.407-410
    • /
    • 1999
  • An experimental investigation to study the behavior of low rise structural walls using high strength concrete is presented. The test parameter included in the study were the level of constant axial load. The shear strength of walls is predicted by the design provision given in the current the American Concrete Institute Building Code ACI 318-95 and Architectural Institute Japan Code AIJ. The predictions are compared with the test results reported herein as well as those available in the literature.

  • PDF

초고층 주상복합 건물에의 초고강도 콘크리트의 시공 및 구조적 성능 (the Application and Structural Behavior of Ultra High Strength Concrete on Sam Sung Sin-Dae Bang project.)

  • 신성우;이광수;최종수;유석형;안종문;윤영수;성상래;백승준;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.313-318
    • /
    • 1994
  • This paper present the application and Structural Behavior of Ultra-High Strength Concrete on Samsung Sin Dae-Bang Housing-Commercial Combined building with 28 story including 8 story basement in seoul. 70 MPa compressive strength has been placed for all 8 basement shear wall. 42 MPa design strength concrete was used for other basement and frame up to 10th floor which us used for commercial purposes

  • PDF

고강도 철근콘크리트 부재에서 철근의 장부작용에 대한 구조변수의 영향 (Influence of Structural Parameters on the Dowel Action of Reinforcing Bar in Reinforced High Strength concrete Members)

  • 최도수;신장호;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.350-355
    • /
    • 1994
  • This study is aimed at the experimental investigation of the influence of the structural parameters such as concrete cover, width of specimen and bar size on the dowel action of reinforcing bari in high strength concrete members. Based on the proper combination of these parameter, a total of 46 specimens has been cast for fc'= 500 ㎏/㎠ and another 46 specimens for fc'= 700 ㎏/㎠, and cured at the laboratory. Comparative analyses have been made for the parametric contribution to the dowel strength from the test results, and a regress equation has been suggested.

  • PDF

PC 박스거더교량의 해석 및 전후처리 시스템 개발연구 (Analysis of the Segmentally Erected Prestressed Concrete Box-Girder Bridges and Pre & Post-Processing)

  • 오병환;이형준;이명규;전세진;박철림;김영진;임선택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 1995
  • In segmentally erected bridges, the structural systems are changed as the construction stages progress and redistribution of member forces occurs due to time dependent effects of concrete and relaxation of perstressing steel. Therefore, structural analysis is required at each construction stage. In this study, nonlinear analysis program of the segmentally erected prestressed concrete box girder bridges is developed to raise the efficiency in making input file for the main program and analysis of the results produced by the main program.

  • PDF

철근 기계적 이음 콘크리트 보의 단순가력에 의한 파괴거동(I) (Structural Behavior of Concrete Beam with Mechanically Spliced Re-bars Subjected to Monotonic Loading (I))

  • 나환선;이현주;권기주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.150-153
    • /
    • 2006
  • The purpose of this research is focused on evaluating the flexural behavior of reinforced concrete beam having 22mm diameter re-bars by lapping methods. To compare the existent lapping method with mechanical lapping methods, four cases of concrete beams were tested to be failed flexurally by monotonic loading. Based on test results, the relations between load and displacement, ductility, maximum load was comparatively analyzed. The structural performance on four cases of members were evaluated.

  • PDF

철근콘크리트 부재에서 철근 부식을 고려한 장기 균열폭 예측 (Corrosion Induced Long Term Crack Width Prediction for Structural Concrete Members)

  • 이기열;양준호;정원용;노삼영;김대중;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.199-200
    • /
    • 2009
  • 본 연구는 균열이 발생한 철근콘크리트 구조 부재에서 공용중 철근 부식과 콘크리트의 건조수축 및 크리프의 영향을 고려한 장기 균열폭을 예측할 수 있도록 부착특성에 기반한 모델을 개발한 것이다.

  • PDF