Development of a simplified equivalent braced frame model for steel plate shear wall systems

  • Chatterjee, Arghya Kamal;Bhowmick, Anjan;Bagchi, Ashutosh
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.711-737
    • /
    • 2015
  • Steel Plate Shear Walls (SPSWs) have been accepted widely as an effective lateral load resisting system. For seismic performance evaluation of a multi-story building with SPSWs, detailed finite element models or a strip model can be used to represent the SPSW components. However, such models often require significant effort for tall or medium height buildings. In order to simplify the analysis process, discrete elements for the framing members can be used. This paper presents development of a simplified equivalent braced model to study the behavior of the SPSWs. The proposed model is expected to facilitate a simplification to the structural modeling of large buildings with SPSWs in order to evaluate the seismic performance using regular structural analysis tools. It is observed that the proposed model can capture the global behavior of the structures quite accurately and potentially aid in the performance-based seismic design of SPSW buildings.

Structural Characteristics of Cell Walls of Forage Grasses - Their Nutritional Evaluation for Ruminants - - Review -

  • Iiyama, Kenji;Tuyet Lam, Thi Bach
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권6호
    • /
    • pp.862-879
    • /
    • 2001
  • The walls of all higher plants are organized as a cellulosic, fibrillar phase embedded in a matrix phase composed of non-cellulosic polysaccharides, some proteins and, in most secondary walls, lignin. At the effective utilization of plant biomass, qualitative and quantitative analyses of plant cell walls are essential. Structural features of individual components are being clarified using newly developed equipments and techniques. However, "empirical" procedures to elucidate plant cell walls, which are not due to scientific definition of components, are still applied in some fields. These procedures may give misunderstanding for the effective utilization of plant biomass. In addition, interesting the investigation of wall organization is moving towards not only qualitatively characterisation, but also quantitation of the associations between wall components. These involve polysaccharide-polysaccharide and polysaccharide-lignin cross-links. Investigation of the associations is being done in order to understand the chemical structure, organization and biosynthesis of the cell wall and physiology of the plants. Procedures for qualitative and quantitative analyses based on the definition of cell wall components are reviewed focussing in nutritional elucidation of forage grasses by ruminant microorganisms.

중층 종합병원 건물의 내진성능평가 (Seismic Performance Evaluation of a Mid-rise General Hospital Building)

  • 김태완;추유림;김승래
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.245-254
    • /
    • 2017
  • The building which are essential for disaster recovery is classified as a special seismic use group. Especially, achievement of seismic performance is very important for the hospital, so the hospital should be able to maintain its function during and right after an earthquake without significant damage on both structural and non-structural elements. Therefore, this study aimed at checking the seismic performance of a hospital building, but which was limited to structural elements. For the goal, a plan with a configuration of general hospitals in Korea was selected and designed by two different seismic-force-resisting systems. In analytical modeling, the shear behavior of the wall was represented by three inelastic properties as well as elastic. Nonlinear dynamic analyses were conducted to evaluate the performance of structural members. The result showed that the performance of shear walls in the hospital buildings was not satisfied regardless of the seismic-force-resisting systems, while the demands on the beams and columns did not exceed the capacities. This is the result of only considering the shear of the wall as the force-controlled action. When the shear of the wall was modeled as inelastic, the walls were yielded in shear, and as the result, the demands for frames were increased. However, the increase did not exceed the capacities of the frames members. Consequently, since the performance of walls is significant to determine the seismic performance of a hospital building, it will be essential to establish a definite method of modeling shear behavior of walls and judging their performance.

Experimental investigation of retrofitted shear walls reinforced with welded wire mesh fabric

  • Yuksel, Suleyman B.
    • Structural Engineering and Mechanics
    • /
    • 제70권2호
    • /
    • pp.133-141
    • /
    • 2019
  • The aim of the present paper is to present the cyclic behavior of strengthened reinforced concrete shear wall test specimen, which was reinforced with cold drawn welded wire mesh fabric. Two reinforced concrete shear wall specimens have been tested in the present study. The walls were tested under reversed cyclic loading with loading applied near the tip of the walls. The control wall is tested in its original state to serve as a baseline for the evaluation of the repair and strengthening techniques. The two test specimens include a control wall and a repaired wall. The control wall test specimen was designed and detailed to simulate non-ductile reinforced concrete shear walls that do not meet the modern seismic provisions. The response of the original wall was associated with the brittle failure. The control shear wall was repaired by addition of the reinforcements and the concrete and then it was reloaded. The effectiveness of the repair technique was investigated. Test results indicate that there can be a near full restoration of the walls' strength. The data from this test, augmenting other data available in the literature, will be useful in calibrating improved analytical methods as they are developed.

메움벽에 의한 R/C 골조의 내진성능 평가에 관한 연구 (Experimental Study of Infilled Wall in Reinforced Concrete Structure)

  • 김석균;김정한;김영문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.403-406
    • /
    • 1999
  • Although infilled wall considered as a non-structural element, the infilled applied in reinforced concrete frame structural systems represents an important element influencing the behaviour and the stability of a structure under seismic effect. This research is performed an experimental investigation of gravity-load designed single-stroy, single-bay, low-rise nonseismic moment-resisting reinforced concrete frame 2 dimension specimens to evaluate the effect of seismic capacity. For pseudo static test, it was manufactured one half scale specimens of two types (Bare Frame, Infilled Frame) based on typical building. The results of these experiments provided regarding the global as well as the local responses of 1) Crack pattern and failure modes, 2) Stiffness, strength.

  • PDF

천장시스템의 동특성 식별 및 인접 구조물과의 충돌을 고려한 동적응답해석 (Identification of Dynamic Characteristics and Numerical Analysis of Ceiling System Considering Collision Adjacent Structures)

  • 전민준;주보근;조봉호;이상현
    • 한국전산구조공학회논문집
    • /
    • 제32권4호
    • /
    • pp.205-213
    • /
    • 2019
  • 2017년 발생한 포항 지진으로 인하여 천장재, 외장재, 커튼월 등 비구조재의 파괴에 의한 피해가 다수 보고되었으며 비구조재의 내진설계가 중요해지고 있다. 본 연구에서는 임팩트해머 테스트를 통해 행어볼트 길이에 따른 천장재의 고유진동수와 감쇠비를 식별하였다. 또한 천장재가 벽 또는 다른 구조체에 충돌하는 경우 발생하는 충격효과를 정확히 고려하기 위해 충돌실험을 수행하였다. 식별된 천장재의 동특성과 충격지속시간을 바탕으로 실제로 천장재가 지진하중으로 인하여 주변 구조물과 충돌이 발생하는 경우에 대한 천장재 응답특성을 수치해석을 통하여 분석하였다. 수치해석 시뮬레이션 결과, 충격하중은 이격거리에 따라 선형적으로 증가하는 경향을 보였으며, 달대길이와는 무관한 것으로 나타났다.

Upgrading flexural performance of prefabricated sandwich panels under vertical loading

  • Kabir, M.Z.;Rezaifar, O.;Rahbar, M.R.
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.277-295
    • /
    • 2007
  • 3-D wall panels are used in construction of exterior and interior bearing and non-load bearing walls and floors of building of all types of construction. Fast construction, thermal insulation, reduced labor expense and weight saving are the most well pronounced advantage of such precast system. When the structural performance is concerned, the main disadvantage of 3D panel, when used as floor slab, is their brittleness in flexure. The current study focuses on upgrading ductility and load carrying capacity of 3D slabs in two different ways; using additional tension reinforcement, and inserting a longitudinal concentrated beam. The research is carried on both experimentally and numerically. The structural performance in terms of load carrying capacity and flexural ductility are discussed in details. The obtained results could give better understanding and design consideration of such prefabricated system.

Seismic Isolation Systems Incorporating with RC Core Walls and Precast Concrete Perimeter Frames -Shimizu Corporation Tokyo Headquarter-

  • Shimazaki, Dai;Nakagawa, Kentaro
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.181-189
    • /
    • 2015
  • Shimizu Corporation Tokyo Headquarters, one of the city's leading office buildings, features many pioneering technologies that contribute to a sustainable society through environmental stewardship and a sophisticated disaster management facility. In terms of structural engineering, a seismic isolation system incorporating reinforced concrete core walls and precast concrete perimeter frames create a robust structure in the event of a large earthquake. In addition to the seismic resistance of the structure, several pioneering construction methods and materials are adopted. This office building can serve as a basis for new design and construction approaches and methodologies to ensure safe and economical structures.

개구부가 있는 비내력벽을 고려한 저층 RC골조구조물의 지진거동 평가 (Evaluation of Seismic Behavior for Masonry Infilled RC Moment Resisting Frame with Openings)

  • 고현;박용구;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.483-489
    • /
    • 2008
  • Masonry infill walls are frequently used as interior partitions and exterior walls in low- or middlerise RC buildings In the structural design and assessment of structural behaviors of buildings, the infill walls are usually treated as non-structural elements and they are ignored in analytical models. In this study, seismic behaviors of RC frame with/without masonry infill walls were investigated. To this end, the infill walls were modeled as equivalent diagonal struts. Based on analytical results, it has been shown that masonry infill walls can increase the global strength and stiffness of a structure. Accordingly, inter-story drift ratio will be decreased but seismic forces applied to the structure were increased than design seismic load because natural period of the structure was decreased. It is also seen from the analytical results that the inelastic deformation of RC frame with soft story is concentrated on the first story columns and thus, partial damage may have possibility of collapse of system.

  • PDF

건축용 비내력 경량벽체의 내충격성 시험방법의 표준화 (Standardization of Impact Test Methods of Non-bearing Lightweight Wall for Building)

  • 김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.181-182
    • /
    • 2015
  • The use of non-bearing light weight wall has increased recently due to the increase of high-rise buildings and supply of long-life housing. Light weight wall has advantages such as reducing the self-weight of the building, convenience in installation, and shortening construction period, however, must have a sufficient strength to external force. This study standardized the impact resistance test method for light weight walls by using the actual impact load obtained through load analysis test in previous studies. The impact resistance test method was divided into the test method that uses soft body and the one that uses hard body. The size of specimen was set up as height 2.4m and width 3.0m. The size and shape of the body followed those used in BS 5234-2 and so on for the compatibility with the test method used overseas. The judgment criteria for impact resistance based on test results were not defined uniformly as the assessment of functional damage can vary depending on the type of material, structural method, purpose of wall, and so on even when the same impact load was applied.

  • PDF