• Title/Summary/Keyword: Structural Retrofit

Search Result 264, Processing Time 0.019 seconds

Shotcrete-Retrofit of Shear Walls with an Opening (개구부를 가지는 전단벽의 숏크리트 보강)

  • Choi, Youn-Cheul;Choi, Chang-Sik;Kim, Hyun-Min;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.71-80
    • /
    • 2007
  • Because of the characteristics relating to high tensile ductility, High Performance Fiber Reinforced Cementitious Composites (HPFRCC) are studied to be adopted in repair and retrofit of buildings. A series of three shear wall specimens was tested under constant axial stress and reversed cyclic lateral loading in order to evaluate the seismic retrofit that had been proposed for the shear wall with the opening. The retrofit involved the use of newly developed ECC and MDF(Macro Defect Free), both of which are sprayed through the high pressure pump, over the entire face of the wall. The results indicate that two difference types of retrofitting strategy make the different effects of a rise in the strength and ductility of each specimen.

Steel hysteretic column dampers for seismic retrofit of soft-first-story structures

  • Javidan, Mohammad Mahdi;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • v.37 no.3
    • /
    • pp.259-272
    • /
    • 2020
  • In this study a new hysteretic damper for seismic retrofit of soft-first story structures is proposed and its seismic retrofit effect is evaluated. The damper consists of one steel column member and two flexural fuses at both ends made of steel plates with reduced section, which can be placed right beside existing columns in order to minimize interference with passengers and automobiles in the installed bays. The relative displacement between the stories forms flexural plastic hinges at the fuses and dissipate seismic energy. The theoretical formulation and the design procedure based on plastic analysis is provided for the proposed damper, and the results are compared with a detailed finite-element (FE) model. In order to apply the damper in structural analysis, a macromodel of the damper is also developed and calibrated by the derived theoretical formulas. The results are compared with the detailed FE analysis, and the efficiency of the damper is further validated by the seismic retrofit of a case study structure and assessing its seismic performance before and after the retrofit. The results show that the proposed hysteretic damper can be used effectively in reducing damage to soft-first story structures.

Probabilistic seismic and fire assessment of an existing reinforced concrete building and retrofit design

  • Miano, Andrea;de Silva, Donatella;Compagnone, Alberto;Chiumiento, Giovanni
    • Structural Engineering and Mechanics
    • /
    • v.74 no.4
    • /
    • pp.481-494
    • /
    • 2020
  • In this paper, a probability-based procedure to evaluate the performance of existing RC structures exposed to seismic and fire actions is presented. The procedure is demonstrated with reference to an existing old school building, located in Italy. The vulnerability assessment of the building highlights deficiencies under both static and seismic loads. Retrofit operations are designed to achieve the seismic safety. The idea of the work consists in assessing the performance of the existing and retrofitted building in terms of both the seismic and fire resistance. The seismic retrofit and fire resistance upgrading follow different paths, depending on the specific configuration of the building. A good seismic retrofit does not entail an improving of the fire resistance and vice versa. The goal of the current work is to study the variation of response due to the uncertainties considered in records/fire curves selection and to carry out the assessment of the studied RC structure by obtaining fragility curves under the effect of different records/temperature. The results show the fragility curves before and after retrofit operations and both in terms of seismic performance and fire resistance performance, measuring the percent improving for the different limit states.

Optimal seismic retrofit design method for asymmetric soft first-story structures

  • Dereje, Assefa Jonathan;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • v.81 no.6
    • /
    • pp.677-689
    • /
    • 2022
  • Generally, the goal of seismic retrofit design of an existing structure using energy dissipation devices is to determine the optimum design parameters of a retrofit device to satisfy a specified limit state with minimum cost. However, the presence of multiple parameters to be optimized and the computational complexity of performing non-linear analysis make it difficult to find the optimal design parameters in the realistic 3D structure. In this study, genetic algorithm-based optimal seismic retrofit methods for determining the required number, yield strength, and location of steel slit dampers are proposed to retrofit an asymmetric soft first-story structure. These methods use a multi-objective and single-objective evolutionary algorithms, each of which varies in computational complexity and incorporates nonlinear time-history analysis to determine seismic performance. Pareto-optimal solutions of the multi-objective optimization are found using a non-dominated sorting genetic algorithm (NSGA-II). It is demonstrated that the developed multi-objective optimization methods can determine the optimum number, yield strength, and location of dampers that satisfy the given limit state of a three-dimensional asymmetric soft first-story structure. It is also shown that the single-objective distribution method based on minimizing plan-wise stiffness eccentricity turns out to produce similar number of dampers in optimum locations without time consuming nonlinear dynamic analysis.

Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure (변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정)

  • Seol, Yun Jeong;Park, Ji-Hun;Kwak, Byeong Hun;Kim, Dae Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

Assessment of seismic retrofitting for soft-story buildings using gapped inclined brace system

  • Tohamy, Mohamed. A.;Elsayed, Mostafa. M.;Akl, Adel. Y.
    • Earthquakes and Structures
    • /
    • v.22 no.3
    • /
    • pp.319-330
    • /
    • 2022
  • Retrofit of soft-story buildings due to seismic loads using Gap-Inclined-Brace (GIB) system is considered a new retrofit technique that aims to maintain both strength and stiffness of structure. In addition, it provides more ductility and less P-delta effect, and subsequently better performance is observed. In this paper, the effect of the eccentricity between GIB and the retrofitted column due to installation on the efficiency of the retrofitting system is studied. In addition, a modification in the determination method of GIB properties is introduced to reduce the eccentricity effect. Also, the effect of GIB system on the seismic response of mid-rise buildings with different heights considering soft-story at various heights has been studied. A numerical model is developed to study the impact of such system on the response of retrofitted soft-story buildings under the action of seismic loads. To achieve that goal, this model is used to perform a numerical investigation, by considering five case study scenarios represent several locations of soft-story of two mid-rise reinforced concrete buildings. At first, Non-linear static pushover analysis was carried out to develop the capacity curves for case studies. Then, Non-linear time history analyses using ten earthquake records with five peak ground accelerations is performed for each case study scenario before and after retrofitting with GIB. The results show that large GIB eccentricity reduce the ultimate lateral resistance and deformation capacity of the retrofitting system. Moreover, the higher the retrofitted building, the more deformation capacity is observed but without significant increase in ultimate lateral resistance.

Mechanics model of novel compound metal damper based on Bi-objective shape optimization

  • He, Haoxiang;Ding, Jiawei;Huang, Lei
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.363-371
    • /
    • 2022
  • Traditional metal dampers have disadvantages such as a higher yield point and inadequate adjustability. The experimental results show that the low yield point steel has superior energy dissipation hysteretic capacity and can be applied to seismic structures. To overcome these deficiencies, a novel compound metal damper comprising both low yield point steel plates and common steel plates is presented. The optimization objectives, including "maximum rigidity" and "full stress state", are proposed to obtain the optimal edge shape of a compound metal damper. The numerical results show that the optimized composite metal damper has the advantages such as full hysteresis curve, uniform stress distribution, more sufficient energy consumption, and it can adjust the yield strength of the damper according to the engineering requirements. In view of the mechanical characteristics of the compound metal damper, the equivalent model of eccentric cross bracing is established, and the approximate analytical solution of the yield strength and the yield displacement is proposed. A nonlinear simulation analysis is carried out for the overall aseismic capacity of three-layer-frame structures with a compound metal damper. It is verified that a compound metal damper has better energy dissipation capacity and superior seismic performance, especially for a damper with double-objective optimized shape.

Structural Performance of Connection element composed of High Performance Fiber Reinforced Cementitious composites and Steel Bars in Brace (브레이스에서 고인성시멘트 복합체와 강봉으로 구성된 접합요소의 구조성능)

  • Lee Young Oh;Yang Il Seung;Han Byung Chan;Park Wan Shin;Yun Hyun Do;Moon Youn Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.231-234
    • /
    • 2005
  • Steel braced frames retrofit method has been broadly used due to their effectiveness in both light weight and construction periods. However, steel braced frames retrofit method has difficulties in application on the inner frames of buildings to be retrofitted consequently, there have been demands for the braced frames retrofit method that can be broadly and easily applicable to both inner and outer frames of the buildings. The objective of this study is to develop and evaluate the seismic retrofit method applicable to the inner frame also by dividing the reinforcing frames into three unit. From the cyclic test of specimens, the test results dearly showed that steel brace using HPFRCCs and steel bars ensure the better cyclic compressive performance than the normal braced members.

  • PDF

Vulnerability assessment and retrofit solutions of precast industrial structures

  • Belleri, Andrea;Torquati, Mauro;Riva, Paolo;Nascimbene, Roberto
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.801-820
    • /
    • 2015
  • The seismic sequence which hit the Northern Italian territory in 2012 produced extensive damage to reinforced concrete (RC) precast buildings typically adopted as industrial facilities. The considered damaged buildings are constituted by one-storey precast structures with RC columns connected to the ground by means of isolated socket foundations. The roof structural layout is composed of pre-stressed RC beams supporting pre-stressed RC floor elements, both designed as simply supported beams. The observed damage pattern, already highlighted in previous earthquakes, is mainly related to insufficient connection strength and ductility or to the absence of mechanical devices, being the connections designed neglecting seismic loads or neglecting displacement and rotation compatibility between adjacent elements. Following the vulnerabilities emerged in past seismic events, the paper investigates the seismic performance of industrial facilities typical of the Italian territory. The European building code seismic assessment methodologies are presented and discussed, as well as the retrofit interventions required to achieve an appropriate level of seismic capacity. The assessment procedure and retrofit solutions are applied to a selected case study.

Design procedure for seismic retrofit of RC beam-column joint using single diagonal haunch

  • Zabihi, Alireza;Tsang, Hing-Ho;Gad, Emad F.;Wilson, John L.
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.341-350
    • /
    • 2019
  • Exterior beam-column joint is typically the weakest link in a limited-ductile reinforced concrete (RC) frame structure. The use of diagonal haunch element has been considered as a desirable seismic retrofit option for reducing the seismic demand at the joint. Previous research globally has focused on implementing double haunches, while the use of single haunch element as a less-invasive and more architecturally favorable retrofit option has not been investigated. In this paper, the key formulations and a design procedure for the single haunch system for retrofitting RC exterior beam-column joint are developed. An application of the proposed design procedure is then illustrated through a case study.