• Title/Summary/Keyword: Stripping efficiency

Search Result 94, Processing Time 0.021 seconds

Separation of Molybdenum and Tungsten from Sulfuric acid Solution by Solvent Extraction with Alamine 336 (황산용액에서 Alamine 336에 의한 용매추출로 몰리브덴과 텅스텐의 분리)

  • Nguyen, Thi Hong;Lee, Man Seung
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.16-23
    • /
    • 2016
  • The separation behaviour of Mo and W from sulfuric acid solution by solvent extraction with Alamine 336 was investigated as a function of solution pH and extractant concentration. Selective extraction of Mo over W by Alamine 336 was obtained in the pH range of 3-5 with low amine concentration. The mixture of Alamine 336 and acidic extractants improved the separation factor between Mo and W and was in the following order: D2EPHA > PC88A > Decanol > Versatic acid. The stripping efficiency of Mo and W from the loaded mixture of Alamine 336 and D2EHPA was very poor, while complete stripping of Mo and W was possible from the mixture of Alamine 336 and Decanol by using a mixture of $NH_4OH$ and $NH_4Cl$.

Li-free Thin-Film Batteries with Structural Configuration of Pt/LiCoO2/LiPON/Cu and Pt/LiCoO2/LiPON/LiCoO2/Cu (Pt/LiCoO2/LiPON/Cu와 Pt/LiCoO2/LiPON/LiCoO2/Cu 구조를 갖는 Li-free 박막전지)

  • Shin, Min-Seon;Kim, Tae-Yeon;Lee, Sung-Man
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.4
    • /
    • pp.243-248
    • /
    • 2018
  • All solid state thin film batteries with two types of cell structure, Pt / $LiCoO_2$ / LiPON / Cu and Pt / $LiCoO_2$ / LiPON / $LiCoO_2$ / Cu, are prepared and their electrochemical performances are investigated to evaluate the effect of $LiCoO_2$ interlayer at the interface of LiPON / Cu. The crystallinity of the deposited $LiCoO_2$ thin films is confirmed by XRD and Raman analysis. The crystalline $LiCoO_2$ cathode thin film is obtained and $LiCoO_2$ as the interlayer appears to be amorphous. The surface morphology of Cu current collector after cycling of the batteries is observed by AFM. The presence of a 10 nm-thick layer of $LiCoO_2$ at the interface of LiPON / Cu enhances the interfacial adhesion and reduces the interfacial resistance. As a result, Li plating / stripping at the interface of LiPON / Cu during charge/discharge reaction takes place more uniformly on Cu current collector, while without the interlayer of $LiCoO_2$ at the interface of LiPON / Cu, the Li plating / stripping is localized on current collector. The thin film batteries with the interlayer of $LiCoO_2$ at the interface of LiPON / Cu exhibits enhanced initial coulombic efficiency, reversible capacity and cycling stability. The thickness of the anode current collector Cu also appears to be crucial for electrochemical performances of all solid state thin film batteries.

Stripping of Ion-Implanted Photoresist Using Cosolvent-Modified Supercritical Carbon Dioxide (공용매로 변형된 초임계 이산화탄소를 이용한 이온 주입 포토레지스트 세정)

  • Jung, In-Il;Kim, Ju-Won;Lee, Sang-Yun;Kim, Woo-Sik;Ryu, Jong-Hoon;Lim, Gio-Bin
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.27-32
    • /
    • 2005
  • We propose an effective and environmentally friendly dry stripping method using a supercritical carbon dioxide ($SCCO_2$) system modified by a single and multiple cosolvents to remove ion-implanted photoresist and residue from a wafer surface at three different temperatures (97, 148, $200^{\circ}C$) and pressures (200, 300, 400 bar). After high dose of ion implantation the photoresist was not easily removed by using pure $SCCO_2$, but swollen. The $SCCO_2$ system modified by single cosolvents and multiple cosolvents mixed with aprotic solvents could not effectively remove the heavy organics, but swell them. However, the $SCCO_2$ system modified with multiple cosolvent (5%, v/v) composed of DMSO and DIW showed high removal efficiency for ion-implanted photoresists at $97^{\circ}C$ and 200 bar for 30 min (about 80%). In this study it has been shown that the dry stripping method using $SCCO_2$ system modified with multiple cosolvents could replace either plasma ashing or acid and solvent wet bench method and dramatically reduce accompanied chemical usage and disposal.

Effect of NaOCl and Gold Plating Additive on the Gold Recovery in Cyclone Electrolytic Cell from Solution for Stripping Gold of PCB by Cyanide (시안을 이용한 PCB 금 박리용액으로부터 사이클론 전해조에서의 금 회수거동에 미치는 차아염소산나트륨과 금 도금첨가제의 영향)

  • Jo, Hyeonji;Yoo, Kyoungkeun;Bae, Mooki;Sohn, Jeongsoo;Yang, Donghyo;Kim, Sookyung
    • Resources Recycling
    • /
    • v.26 no.4
    • /
    • pp.88-94
    • /
    • 2017
  • The recovery of gold in cyclone type electrolytic cell was conducted from solution for stripping gold of PCB by cyanide. The electrolytic recovery behaviors of gold was investigated by reaction time and addition of electrolytic sodium hypochlorite (NaOCl) and gold plating additive (KG-120). Because the electrolysis generated NaOCl reacted with the cyanide in the leachate by alkaline chlorination, more than 99% of the cyanide was removed at a $NaOCl(g)/CN^-(g)$ ratio of 1.0. When NaOCl was added during the recovery of the gold from cyanide leachate in the cyclone electrolytic cell, the recovery of gold was 98% at the ratio of $NaOCl(g)/CN^-(g)$ from 0.5 to 2.5 in 480 minutes and decreased rapidly over the ratio of 3.0. Gold was recovered more than 99% by adding 1.5 and 4.5%(v/v) of KG-120 with NaOCl in 480 minutes. In particular, when the concentration of KG-120 was 3.5 and 4.5%(v/v), more than 96% of gold was recovered within 240 minutes and the initial recovery rate was relatively faster. The optimum concentration of KG-120 is 3.5%(v/v) considering the economic feasibility and efficiency.

A Study of Design Parameter for the Field Application of High Performance Permanent Form (HPPF) Using Stainless Steel Fiber (스테인레스 강섬유를 이용한 고성능 영구거푸집적용 벽체구조물의 설계변수 연구)

  • Sim, Jong Sung;Oh, Hong Seob;Ju, Min Kwan;Ha, Woo Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.59-66
    • /
    • 2008
  • In the construction site, to improve the man-dependent form work, non-stripping form has been studied but the developed non-stripping form was hard to applied with respect to the cost, form size and performance. This study is for evaluating the adaptability of the developed non-stripping form named as high performance permanent form (HPPF). To do this, the analytical approach and parametric study were performed based on the research for fundamental material characteristic of the HPPF. The target concrete structure is a wall structure because of its effectiveness of HPPF. To evaluate the structural efficiency of the HPPF applied wall structure, FEM analysis was performed to decide the maximum placing height at one time then it was applied to design the wall structure. In the result of the analysis, the HPPF applied wall structure showed the lots of advantages that it can reduce the cost resulted from reducing concrete and steel rebar even if it has same structural performance to the conventional concrete wall structure with same dimension. With this analysis result, it can be evaluated that the HPPF applied concrete structure can be a concrete structure with the long term durability in site.

Characterization of polymer inclusion membrane containing Aliquat 336 as a carrier

  • Manzak, Aynur;Yildiz, Yasemin;Tutkun, Osman
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.95-102
    • /
    • 2015
  • The presented research is about characterization of Cellulose Triacetate (CTA) based Polymer Inclusion Membranes (PIMs) which incorporated the commercial extractant Aliquat 336, Tributylphosphate (TBP) as modifier and 2-Nitro Phenyl Pentyl Ether (NPPE) as plasticizer, for the preparation of the membranes. Chemical and physical characteristics of the synthesized membranes especially membrane thickness and side difference effects were investigated. Different surface structures and membrane thickness affect the extraction efficiency of membranes. Membrane extraction experiments were studied where the glass-facing surface of the membranes placed next to feed phase and the air-facing surface to stripping phase. The membrane was characterized by means of AFM, FT-IR and SEM.

Effect of Nanostructures of Au Electrodes on the Electrochemical Detection of As

  • Kastro, Kanido Camerun;Seo, Min Ji;Jeong, Hwakyeung;Kim, Jongwon
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.206-213
    • /
    • 2019
  • The development of simple methods for As detection has received great attention because As is a toxic chemical element causing environmental and health-related issues. In this work, the effect of nanostructures of Au electrodes on their electroanalytical performance during As detection was investigated. Different Au nanostructures with various surface morphologies such as nanoplate Au, nanospike Au, and dendritic Au structures were prepared, and their electrochemical behaviors toward square-wave anodic stripping voltammetric As detection were examined. The difference in intrinsic efficiency for As detection between nanostructured and flat Au electrodes was explained based on the crystallographic orientations of Au surfaces, as examined by the underpotential deposition of Pb. The most efficient As detection performance was obtained with nanoplate Au electrodes, and the effects of the pre-deposition time and interference on As detection of the nanoplate Au electrodes were also investigated.

Absorption and Regeneration of Carbon Dioxide in Aqueous AMP + AEPD and AMP + TIPA Solutions (AMP + AEPD와 AMP + TIPA 수용액을 이용한 이산화탄소의 흡수 및 재생)

  • Kim, Mi-Sook;Choi, Won-Joon;Seo, Jong-Beom;Cho, Ki-Chul;Kim, Soo-Gon;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.539-546
    • /
    • 2007
  • Increasing emission of $CO_2$ significantly effects the global warming. Chemical absorption is one of separation methods of $CO_2$ from the industrial flue gases. In this study, the $CO_2$ removal efficiency as well as the $CO_2$ absorption amount of aqueous AMP (2-amino-2-methyl-1-propanol) solutions were measured using the continuous absorption and regeneration apparatus. We investigated the effect of aqueous AMP+AEPD(2-amino-2-ethyl-1, 3-propanediol) and AMP+TIPA (triisopropanolamine) solutions to enhance absorption characteristics of AMP. As a result of this study, the absorption amount and $CO_2$ removal efficiency were increased with adding TIPA into 30 wt.% AMP. The absorption amount and $CO_2$ removal efficiency of aqueous 30 wt.% AMP+5 wt.% TIPA solution were $1.70\;kg-CO_2/kg-absorbent$ and 91.1%, while those of aqueous 30 wt.% AMP solution were $1.58\;kg-CO_2/kg-absorbent$ and 89.3%. In addition, aqueous 30 wt.% AMP+5 wt.% TIPA solution used in the study revealed the high stripping efficiency, which was almost 98%, at the temperature of $110^{\circ}C$. Thus, the temperature of regenerator should be operated at $110^{\circ}C$.

Characteristics of Ammonia Removal from a Synthetic Wastewater in a Jet Loop Reactor with a Two-fluid Venturi-type Swirl Nozzle (이유체 벤츄리형 선회 노즐이 장착된 제트 루프 반응기에서 합성폐수 중의 암모니아 제거특성)

  • Noh, Da-ji;Yun, Chan-Su;Lim, Jun-Heok;Won, Yong-Sun;Lee, Tae-Yoon;Lee, Jea-Keun
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2017
  • We investigated the performance of a jet loop reactor (JLR) with the two-fluid venturi-type swirl nozzle (TVSN) during experiment for ammonia removal by air stripping from a synthetic wastewater, and compared it with that of a JLR with the two-fluid venturi-type conventional nozzle (TVCN), with the variation of pH, liquid circulation rate ($Q_L$), and air flow rate ($Q_G$). Their performance levels were compared based on the ammonia removal efficiency and overall mass transfer coefficient ($K_La$). Investigated parameters in a JLR were pH (10-12), air flow rate ($Q_G=5-20L\;min^{-1}$), and liquid circulation rate ($Q_L=25-35L\;min^{-1}$). Throughout the experiment, the ammonia removal efficiency and $K_La$ in a JLR with TVSN was higher than in a JLR with TVCN. This may be due to the enhanced turbulent intensity by swirling flow formed in the JLR with TVSN compared to that with TVCN. Further, we obtained higher $K_La$ when pH, $Q_L$ and $Q_G$ were increased. In particular, $K_La$ was increased more efficiently by increasing $Q_G$ than by increasing pH and $Q_L$.

Effect of Air Distributor Pore Size in Foam Separator of Sea Water (해수의 포말분리시 공기분산기 기공크기 영향)

  • SUH Kuen-Hack;KIM Byong-Jin;LEE Jung-Hoon;LIM Jun-Heok;YI Gyeongbeom;KIM Yong-Ha;JO Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.3
    • /
    • pp.254-262
    • /
    • 2003
  • Effect of the air distributor pore size for the removal of aquacultural waste, such as protein, total suspended solids (TSS), chemical oxygen demand (COD), turbidity and total ammonia nitrogen (TAN) from sea water was investigated by using foam separator. With the increase of pore size of air distributor, removal rates and efficiency of protein decreased. Removal rate by commercial air stone was in the range between the removal rates by G2 and G4 sintered glass discs. Within the range of pore size distributor from Gl to G4, the removal efficiency of protein were ranged from 21 to $42\%.$ The changes of removal rates and efficiencies of TSS, COD and turbidity were similar to proteins. TAN was removed by stripping. The pore size of air distributor for a higher overall oxygen mass transfer coefficient and saturation efficiency provided the condition for higher protein removal rate. Also the foam separator could be used as an aerator.