• Title/Summary/Keyword: Strip method

Search Result 890, Processing Time 0.024 seconds

Improvement of PR Stripper Efficient and Change of Surface Hardness for HDI-PR Used by PLVA Method (PLVA 방법을 활용한 PR Stripper의 성능 향상과 HDI-PR 표면의 내력 변화 연구)

  • Kim, Soo-In;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.544-548
    • /
    • 2008
  • At the semiconductor industry, Photoresist(PR) strip progress has high cost and time consuming process. Accordingly, many research group have been focused on the shortening of the PR strip progress. But the replacements of newly developed materials rather than normally used strip have accompanied by cost consumption. Therefore, we suggested the Plasma Liquid-Vapor Activation (PLVA) method of general PR strip solution for saving the PR strip time and the high strip rate of PR residue. The PLVA method was very effective for PR strip progress. Also, the ion damaged PR(high dose implanted photoresist: HDI-PR) was almost impossible to strip. However, it was very difficult to characterize the change of chemical composition of HDI-PR between with and without PLVA method. Thus, physical properties of HDI-PR surface with and without PLVA method were measured by using the nano-indenter system.

HOT STRIP WIDTH CONTROL METHOD BY USING LOOPER TENSION MEASURING SYSTEM IN FINISHING MILL (열간 사상압연 투퍼장력 측정에의한 열연판폭제어)

  • 홍완기;김필호;문영훈;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.423-428
    • /
    • 1999
  • A high precision hot strip width control method has been developed in this study by applying interstand looper tension measuring system at finishing mill stands. As with deviation of hot rolled steel strip is closely related to abnormal increase in the interstand strip tension, on-line measuring device of looped tension and data analyzing system was developed in this study. To determine dominant factors that will cause local width shortage, the logged data sets of bar width, bar thickness, looper tension, and strip thickness along the strip length were correlated with the data set of strip width change. With the result of the correlation analysis, existing sequence control logic and parameters for looper actuator were modified for strip width quality and the gains of the looper control were refined for the stable operation during the full passage of rolled strip. The on-line tension measurement and tension feedback control for looper system improved strip travelling stability and reduced strip width deviation in the srip top end region.

  • PDF

An Analysis of Hot-Rolling in the Twin-Roll Strip Casting Process by using the Slab Method (슬랩법을 이용한 쌍롤식 박판주조 공정의 열간 압연 해석)

  • Shim, Hyun-Bo
    • Transactions of Materials Processing
    • /
    • v.3 no.1
    • /
    • pp.63-83
    • /
    • 1994
  • In this paper, the slab method have been applied to investigate the strip casting process in which hot coil is produced from molten steel directly. In the twin roll strip casting process, molten steel supplied by the nozzle cools and solidifies due to the heat extraction effect of the rolls and hot rolling of the solidified shell takes place simultaneously. The analysis of hot rolling has been carried out by using the existing results of solidification analysis for the twin roll strip casting process. The current slab method provides basic design data such as roll separation force, rolling torque, rolling power as well as end dam separation force which are required to design strip caster. The effect of friction on the basic process parameters are investigated also. It is shown that the use of appropriate friction coefficient is important and that the characteristics of hot rolling in the twin-roll strip casting process is quite different from the conventional hot rolling processes.

  • PDF

Tension Control of Hot Strip Finishing Mill (열간 사상압연 공정의 장력제어)

  • 이동욱;안병준;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.322-325
    • /
    • 2002
  • We describe the looper controller design for a hot strip mill. The looper is to control the strip tension which influences on the width of the strip. It is very important to control the looper control of the hot strip mill, but difficult to control the looper, because there exists on mutual interaction among strip gauge, looper angle, and strip tension. In this paper, we present the modeling for the hot strip finishing mill to control the tension of the strip and suggest a cross control method. The cross control is a very simple method that allows non-interacting control.

  • PDF

The Tension Control by using CDM of the Full Stand Hot Finishing Mill

  • Lee, Dong-Wook;Ahn, Byoung-Joon;Kim, Young-Ho;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.67.1-67
    • /
    • 2002
  • We describe the looper controller design for a hot strip mill. The looper is to control the strip tension which influences on the width of the strip. It is very important to control the looper control of the hot strip mill, but difficult to control the looper, because there exists on mutual interaction among strip gauge, looper angle, and strip tension. In this paper, we present the modeling for the hot strip finishing mill to control the tension of the strip and suggest a cross control method of full-stand hot strip finishing mill. The cross control is a very simple method that allows non-interacting control.

  • PDF

Development of Hot Rolling Process Analysis Simulator and Its Application(II) (열간압연 공정 해석용 시뮬레이터의 개발과 응용(II))

  • 이원호;이상룡
    • Transactions of Materials Processing
    • /
    • v.8 no.1
    • /
    • pp.78-91
    • /
    • 1999
  • The endless hot rolling has been focused as an innovative process technology for increasing the productivity drastically and reducing the imperfection of quality in hot rolled steel strip. To realize it in actual mill, a lots of new facilities such as bar coiler, movable LASER welder and high speed strip shear should be equipped. And also it is necessary to develop the control technique for changing the roll gap and rolling speed during rolling, which is named as Flying Gap and Speed Change control technology. To prevent a strip rupture caused by excessive tension, it is very important to minimize fluctuations in strip thickness and intension during FGSC control. In this paper, the mathematical model for FGSC control algorithm was suggested and dynamic simulation is performed to accertain the effect of suggested control method on fluctuations in strip thickness and tension. For endless hot rolling simulation, a lots of FGSC control situations, for instance - strip thickness change from strip to strip - strip width change from strip to strip - carbon content change from strip to strip are considered.

  • PDF

Analysis and Experiment of Micro-strip Line Lumped Elements for SAW Duplexers (탄성표면파 듀플렉서용 마이크로 스트립라인 집중소자 해석 및 실험)

  • 이승희;노용래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • In this study, we analyzed and experimented micro-strip line inductors and capacitors for a SAW duplexer, an important devise for mobile communication. For SAW duplexers, micro-strip line lumped elements must have small impedance values, below several tens of nH or several tens of pF, and a small area pattern. In this study, we performed theoretical analysis of flat line type, meander line type, and spiral line type inductors and interdigital capacitors on a LiTaO$_3$ Piezo-crystal. We proposed a measurement method to evaluate small values of lumped elements accurately with network analyzer. In experiments, we confirmed validity of the theoretical analysis method through fabrication and characterization of micro-strip line lumped elements. The analysis method in this paper can be applied to SAW duplexers well as other microwave devices.

A Noise Investigation of Transverse Rumble Strip at Toll Plaza of Highway (고속도로 영업소 광장의 횡방향 럼블스트립으로 발생되는 소음 조사)

  • An, Deok-Soon;Suh, Young-Chan;Kwon, Soo-Ahn;Lee, JaeJun;Eom, Byeong-Sik
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.31-36
    • /
    • 2013
  • PURPOSES: This study is to investigate a generated traffic noise when vehicle pass over a transverse rumble strip at toll plaza of highway. METHODS: To investigate traffic noise at toll plaza of highway, Pass-by method which is the most common used for measuring traffic noise was adopted and the traffic noise at toll plaza was measured for 10 min per hour for 11hours(13:00~24:00). RESULTS: The measured traffic noise by pass-by method was changed as function of the transverse rumble strip configuration. Generally, the maximum difference among three noise measurement sections was 7 dB(A). It might be related with traffic speed. Also, the measured traffic noise was strongly generated from a passenger car which was 2 axle. It means that the most of traffic noise on the road is generated at tire/pavement interface of the passenger car. CONCLUSIONS: The traffic noise was strongly related with vehicle speed and transverse rumble strip configuration on the road. For driver safety, the transverse rumble strip is definitely necessary. However, the complaints from residents near highway was increased by traffic noise from transverse rumble strip. Therefore, To satisfy both safety and reduction of traffic noise, the development of configuration of transverse rumble strip is necessary in the further study.

Comparison of strip analysis and HPLC analysis for the quantitative analysis of cyanobacterial toxin (남조류 독소 정량을 위한 스트립분석법과 HPLC 분석법의 비교)

  • Pyo, Dongjin;Yim, Miyeon
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.168-174
    • /
    • 2015
  • Cyanobacterial toxins, such as microcystins, which exist in Korean lakes, are strongly toxic in fish, cattle, and humans. This study performs a quantitative analysis of cyanobacterial toxins in water by comparing the strip method and the HPLC method. Because the detection ranges of the strip method and the HPLC method are different, the water samples were diluted. The comparison of the strip method and the HPLC method was made using seven samples that contained different concentrations of microcystin. The quantitative results produced by the strip analysis were significantly aligned with the results of the HPLC analysis. The results of correlation analysis were r = 0.99998 and p = 0.00001.

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • v.16 no.3
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF