• 제목/요약/키워드: Stress view

Search Result 538, Processing Time 0.03 seconds

Behavior Analysis of Elevator Door (엘리베이터 도어의 거동해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.991-994
    • /
    • 2007
  • Recently, there has been major issue in safety of elevator. In the view of safe management of elevator, the corresponding research must be done since accidents related elevator include not only actual accident but also possible accident in order to protect user from dangerousness. This research aims to seek an analytical solution for safety apparatus which caused accident again and again among dangerous factors of an elevator. In order to assure safety of door, ANSYS, a commercial software was applied and evaluate safety qualitatively by calculating stress and strain deformed under the loads of 40 to 100kg.

  • PDF

Effect of an temperatures of post-spray heat treatment on wear behavior of $8%Y_2O_3-ZrO_2$ coating

  • Chae, Y.H.;Kim, S.S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.181-182
    • /
    • 2002
  • Most recent, Plasma ceramic spray is used on parts of tribosystem, has been investigated on the tribological performance. The application of ceramic coatings by plasma spray has become essential in tribosystems to produce better wear resistance and longer life in various conditions. The purpose of this work was to investigate the wear behavior of $8%Y_2O_3-ZrO_2$ coating due to temperatures of post-spay heat treatment. The plasma-sprayed $8%Y_2O_3--Zirconia$ coating was idiscussed to know the relationship between phase transformations and temperatures of post- spray heat treatment. Wear tests was carried out with ball on disk type on normal load of 50N, 70N and 90N under room temperature. The transformation of phase and the value of residual stress were measured by X-ray diffraction method(XRD). Tribological characteristics and wear mechanisms of coatings was observed by SEM. The tribologieal wear performance was discussed a point of view for residual stress. Consequently. post-spray heat treatment plays an important role in decreasing residual stress. Residual stress in coating system has a significant influence on the wear mechanism of coating.

  • PDF

A Study on The Test Results of Dynamic Stress of Rubber Tired AGT (고무차륜형식 경량전철 차량 동응력 측정 결과 분석 및 결과 고찰)

  • Kwon, Tae;Kim, Young-Sik;Nam, Yang-Hee;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2615-2625
    • /
    • 2011
  • Recently in worldwide and Korea domestically, the LRT vehicles are introduced as reputable urban transit system, in a view of energy saving, punctuality and eco-friendly as well as transport efficiency. At first time in Korea, the Busan metro Line 4 was applied with AGT system which is a kind of LRT using the Rubber tired AGT vehicle and developed from 1999 to 2004 in charge of Korean government. Busan selected the AGT system for Metro Line 4 as the solution of traffic jam and networking the intercity. At present, Busan Metro Line 4 has been running since opened at March 30, 2011. The vehicle of Busan metro line 4 is aiming the maximization of LRT vehicle advantage that is the lightness of vehicle size and vehicle weight. So, it did size downed and weight downed by lightened the weight of car frame and bogies and by the compactness of electrical on-board equipments. The study carried out the structure analysis to verify and safety and performance of car body and bogie frame of Busan Metro Line 4 vehicles. In this study, it was analyzed the stress of main load and verified the fatigue strength. And measured the dynamic stress sending to body structure and bogie frame while running on main line and analyzed the fatigue stress. As a result, it verified the safety and life cycle of car body and bogie frame.

  • PDF

Evaluation of Thermal Stratification and Primary Water Environment Effects on Fatigue Life of Austenitic Piping (열성층 및 냉각재 환경이 오스테나이트 배관의 피로수명에 미치는 영향 평가)

  • Choi, Shin-Beom;Woo, Seung-Wan;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Lee, Jin-Ho;Chung, Hae-Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.660-667
    • /
    • 2008
  • During the last two decades, lots of efforts have been devoted to resolve thermal stratification phenomenon and primary water environment issues. While several effective methods were proposed especially in related to thermally stratified flow analyses and corrosive material resistance experiments, however, lack of details on specific stress and fatigue evaluation make it difficult to quantify structural behaviors. In the present work, effects of the thermal stratification and primary water are numerically examined from a structural integrity point of view. First, a representative austenitic nuclear piping is selected and its stress components at critical locations are calculated in use of four stratified temperature inputs and eight transient conditions. Subsequently, both metal and environmental fatigue usage factors of the piping are determined by manipulating the stress components in accordance with NUREG/CR-5704 as well as ASME B&PV Codes. Key findings from the fatigue evaluation with applicability of pipe and three-dimensional solid finite elements are fully discussed and a recommendation for realistic evaluation is suggested.

Analysis of Start-up Characteristics of a Heat Recovery Steam Generator Considering Thermal Constraints (열적 제한요소를 고려한 열회수 증기발생기의 시동 특성 해석)

  • Kim, Young Il;Kim, Tong Seop;Kim, Jae Hwan;Ro, Sung Tack;Kauh, Sang Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1410-1417
    • /
    • 1999
  • A thorough understanding of the transient behavior during start-up is essential in the design and operation of the heat recovery steam generator(HRSG). During this period of time, material that is exposed to high temperature and experiences a large temperature variation is subject to high thermal stress. In this work, a transient formulation of the HRSG is constructed including the estimation of the thermal stress and fatigue of the drum wall. Start-up behavior of a single-pressure HRSG is analyzed and the effect of bypassing part of the gas turbine exhaust flow on the thermal stress evolution is examined. It is found that the modulation of the gas flow rate using a bypass damper is very useful in view of reducing the thermal stress of the drum and ensuring the fatigue lifetime.

A Review of Postpartum Depression: Focused on Psychoneuroimmunological Interaction (산후 우울의 고찰: 정신신경면역계 상호작용을 중심으로)

  • Kim, Yunmi;Ahn, Sukhee
    • Women's Health Nursing
    • /
    • v.21 no.2
    • /
    • pp.106-114
    • /
    • 2015
  • Purpose: The purpose of this review was to describe a psychoneuroimmunology (PNI) framework for postpartum depression (PPD) and discuss its implications for nursing research and practice for postpartum women. Methods: This study explored the role of hypothalamic-pituitary-adrenal (HPA) axis and inflammation as possible mediators of risk factors for PPD through literature review. Results: From this PNI view, human bodies are designed to respond with the reciprocal interactions among the neuro-endocrine and immune system when they are faced with physical or psychological stressors. Chronic stress induces alterations in the function of HPA axis, and a chronic low-grade inflammatory response is associated with depression. The dysfunctions of cytokines and HPA axis have been observed during the postpartum period. Stress promotes glucocorticoid receptor resistance, which can promote inflammatory responses. This, in turn, can contribute to the pathophysiology of depression. This can especially affect populations at vulnerable time-points, such as women in the postpartum. Conclusion: From a PNI perspective, well-designed prospective research evaluating the role of stress and inflammation as an etiology of PPD and the effect of stress reduction is warranted to prevent PPD.

The Analysis of Stress and Variation of Cement Thickness as the Variation of Design Variables for Custom-Made Hip Implant (Cement Type 맞춤형 인공고관절의 설계 변수 변화에 따른 Cement 두께 변화와 이에 대한 응력 분석)

  • Park, Heung-Seok;Chun, Heoung-Jae;Youn, In-Chan;Lee, Moon-Kyu;Seo, Duck-Chan;Choi, Kui-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.402-408
    • /
    • 2006
  • The choice of suitable hip implant is one of important factors in the total hip arthroplasty (THA). In clinical view point, an improper adaptation of hip implant might induce abnormal stress distribution to the bone, which can shorten the lifespan of replaced hip implant. Currently, interest in the custom-designed hip implants has increased as studies reveal the significance of geometric shape of patient's femur in modeling and designing the implants. In this study, we have developed custom-designed hip implant models with various sizes, and analyzed the stress distribution in the bone and bone cement using the Finite Element Method. It was found that minimizing the gap between implant stem and femoral cavity is crucial to minimize the stress concentration in the bone.

Effect of Sintering lime on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Y Oxide-based Varistors (Zn-Pr-Co-Cr-Y 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 소결시간의 영향)

  • Nahm, Choon-Woo;Park, Jong-Ah;Yoo, Dea-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.615-621
    • /
    • 2005
  • The electrical stability against surge stress of varistors, which are composed of Zn-Pr-Co-Cr-Y oxide system, were investigated at different sintering times. As sintering time increases, the varistor voltage and nonlinear exponent decreased in the range of $279.6\~179.1$ and $52.5\~24.9$, respectively. On the contrary, the leakage current and dielectric dissipation factor increased in the range of $1.2\~9.8\;{\mu}A$ and 0.0461\~0.0651 with increase of sintering time. For all varistors, the variation rates of V-I characteristic parameters against surge stress were more strongly affected in order of varistor voltage ${\rightarrow}nonlnear$ $exponent{\rightarrow}leakage$ current. On the whole, the electrical stability against surge stress increased with increasing sintering time. Conclusively, it is assumed that the varistors sintered for 2 h exhibited comparatively good characteristics, in view of overall characteristics.

Effect of compressible membrane's nonlinear stress-strain behavior on spiral case structure

  • Zhang, Qi-Ling;Wu, He-Gao
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.73-93
    • /
    • 2012
  • With an active structural involvement in spiral case structure (SCS) that is always the design and research focus of hydroelectric power plant (HPP), the compressible membrane sandwiched between steel spiral case and surrounding reinforced concrete was often assumed to be linear elastic material in conventional design analysis of SCS. Unfortunately considerable previous studies have proved that the foam material serving as membrane exhibits essentially nonlinear mechanical behavior. In order to clarify the effect of membrane (foam) material's nonlinear stress-strain behavior on SCS, this work performed a case study on SCS with a compressible membrane using the ABAQUS code after a sound calibration of the employed constitutive model describing foam material. In view of the successful capture of fitted stress-strain curve of test by the FEM program, we recommend an application and dissemination of the simulation technique employed in this work for membrane material description to structural designers of SCS. Even more important, the case study argues that taking into account the nonlinear stress-strain response of membrane material in loading process is definitely essential. However, we hold it unnecessary to consider the membrane material's hysteresis and additionally, employment of nonlinear elastic model for membrane material description is adequate to the structural design of SCS. Understanding and accepting these concepts will help to analyze and predict the structural performance of SCS more accurately in design effort.

A Study on the Development of an Infertility Stress Scale (불임 스트레스 척도 개발에 관한 연구)

  • 김선행;박영주;장성옥
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.141-155
    • /
    • 1995
  • The objective of this study was to develop a scale to measure stress in infertile couples and to test its reliability and validity. Prior to item generation, a basic decision was made to conceptualize stress in infertile couples as including two dimensions and four subdimensions. The dimensions were, intrapersonal stress including cognitive and affective stress, and interpersonal stress including marital and social stress. Initially 95 items were generated from the inter-view data of 31 primary or secondary infertile women and from a literature review. These items were analyzed through the Index of Content Validity(CVI) and 69 items were selected which met 70% or more of the CVI. This preliminary Infertility Stress Scale were analyzed for reliability and construct validity. Item analysis and factor analysis were applied for construct validity. Forty items were selected through item analysis. This procedure was based on the inter-item correlation matrix, a corrected average inter-item correlation coefficient(.30~.70), a corrected item to total correlation coefficient (.03 or more) and information about the alpha estimate if this item was dropped from the scale. The result of the initial factor analysis including varimax rotation produced eight factors. Five items deleted because of factor complexity(indiscriminate factor loadings). The secondary factor analysis including varimax rotation produced seven factors that coincided with the conceptual framework posed for the scale developed. The seven factors were labeled as ‘meaning of children’,‘worthiness’,‘tenacious linking’,‘marital satisfaction’,‘sexual satisfaction’,‘familial adjustment’ and ‘social adjustment’. The alpha coefficient relating to internal consistency was .93 for reliability The results of this study suggest that the measurement derived from the Infertility Stress Scale is useful in assessing the stress of infertile couples.

  • PDF