• Title/Summary/Keyword: Stress perfusion test

Search Result 26, Processing Time 0.035 seconds

Long-term Prognostic Value of Dipyridamole Stress Myocardial SPECT (디피리다몰 부하 심근관류 SPECT의 장기예후 예측능)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Jang, Myung-Jin;Kang, Won-Jun;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Kang, Wee-Chang;Lee, Young-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.39-54
    • /
    • 2000
  • Purpose: Dipyridamole stress myocardial perfusion SPECT could predict prognosis, however, long-term follow-up showed change of hazard ratio in patients with suspected coronary artery disease. We investigated how long normal SPECT could predict the benign prognosis on the long-term follow-up. Materials and Methods: We followed up 1169 patients and divided these patients into groups in whom coronary angiography were performed and were not. Total cardiac event rate and hard event rate were predicted using clinical, angiographic and SPECT findings. Predictive values of normal and abnormal SPECT were examined using survival analysis with Mantel-Haenszel method, multivariate Cox proportional hazard model analysis and newly developed statistical method to test time-invariance of hazard rate and changing point of this rate. Results: Reversible perfusion decrease on myocardial perfusion SPECT predicted higher total cardiac event rate independently and further to angiographic findings. However, myocardial SPECT showed independent but not incremental prognostic values for hard event rate. Hazard ratio of normal perfusion SPECT was changed significantly (p<0.001) and the changing point of hazard rate was 4.4 years of follows up. However, the ratio of abnormal SPECT was not. Conclusion: Dipyridamole stress myocardial perfusion SPECT provided independent prognostic information in patients with known and suspected coronary artery disease. Normal perfusion SPECT predicted least event rate for 4.4 years.

  • PDF

Comparison of $^{99m}Tc$-tetrofosmin and $^{99m}Tc$-sestamibi Myocardial Perfusion SPECT in Detecting Coronary Artery Fisease (부하-휴식 1일 영상법을 이용한 심근관류 SPECT에서 $^{99m}Tc$-tetrofosmin과 $^{99m}Tc$-MIBI의 관동맥질환 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeoung, Hwan-Jeoung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.137-142
    • /
    • 1998
  • Purpose: $^{99m}Tc$-tetrofosmin(TF) is a recently proposed myocardial imaging agent which has similar biokinetic characteristics to $^{99m}Tc$-sestamibi(MIBI). The aim of this study was to compare TF and MIBI myocardial perfusion SPECTs in detecting coronary artery disease. Materials and Methods: One hundred and sixty patients(101 males, 59 females, mean age $57{\pm}9yr$) who had undergone both myocardial perfusion SPECT(M-SPECT) and coronary angiography within 1 month were studied. M-SPECT was performed using TF in 115 patients and MIBI in 45 patients. Stress-rest one day protocol was used in all patients. A coronary stenosis was considered significant when the luminal diameter ${\geq}$50% was compromised. The chi square test was used to compare differences in sensitivity and specificity between the two groups. Results: There was no difference in age and diseased coronary artery branches between the two groups. There were more male patients in TF group: Male-to-female ratios of TF and MIBI groups were 78:37 and 23:22, respectively(p<0.05). The overall sensitivity of TF study was 92% and specificity 36%. The overall sensitivity and specificity of MIBI study were 93% and 30%, respectively. There was no difference between TF and MIBI groups in identifying individual diseased coronary artery branches. Conclusion: One day stress-rest myocardial SPECT using either TF or MIBI was comparable and was a very sensitive test in detecting coronary artery disease.

  • PDF

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position (측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석)

  • Lee, Chungkeun;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

Twin anemia polycythemia sequence in a dichorionic diamniotic pregnancy: a case report

  • Lee, Soo-Young;Bae, Jin Young;Hong, Seong Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.2
    • /
    • pp.150-152
    • /
    • 2022
  • Complications related to the vascular anastomosis of the placental vessels in monochorionic twins are fatal. The clinical syndromes of feto-fetal transfusion include twin anemia polycythemia sequence (TAPS), twin-twin transfusion syndrome, and twin reversed arterial perfusion sequence. We present an extremely rare case of TAPS in a dichorionic diamniotic pregnancy. A 36-year-old woman, gravida 0, para 0, was referred to our hospital with suspected preterm premature membrane rupture. Although her pelvic examination did not reveal specific findings, the non-stress test result showed minimal variability in the first fetus and late deceleration in the second one. An emergency cesarean section was performed. The placenta was fused, and one portion of the placenta was pale, while the other portion was dark red. The hemoglobin level of the first fetus was 7.8 g/dL and that of the second one was 22.2 g/dL.

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

Prediction of Improvement of Myocardial Wall Motion after Coronary Artery Bypass Surgery Using Rest T1-201/Dipyridamole Stress Gated Tc-99m-MIBI/24 Hour Delay T1-201 SPECT (휴식기 T1-201/디피리다몰 부하 게이트 Tc-99m-MIBI/24시간 지연 T1-201 SPECT를 이용한 관상동맥 우회로 수술 후 심근벽 운동 호전의 예측)

  • Lee, Dong-Soo;Lee, Won-Woo;Yeo, Jeong-Seok;Kim, Seok-Ki;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.497-508
    • /
    • 1998
  • Purpose: Using rest T1-201/dipyridamole stress gated Tc-99m-MIBI/ 24 hour delay T1-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), T1-201 rest perfusion (Rest), T1-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. Materials and Methods: In 39 patients (M;F= 34:5, age $58{\pm}8$), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. Results: After bypass surgery, ejection fraction increased from $37.8{\pm}9.0%$ to $45.5{\pm}12.3%$ in 22 patients who had decreased ejection fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Though univariate logistic regression analysis revealed Rev (p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Conclusion: Among independent predictors obtained by rest T1-201/ stress gated Tc-99m-MIBI/ delayed T1-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor.

  • PDF

Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease (Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계)

  • Cho, Jung-Ah;Choi, Chung-Il;Kwak, Dong-Suk;Kim, Jeong-Gyun;Bae, Sun-Kun;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Kang, Seung-Wan;Woo, Eon-Jo;Kim, Sin-Woo;Sohn, Sang-Kyun;Chae, Shung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.