• Title/Summary/Keyword: Stress controllers

Search Result 19, Processing Time 0.02 seconds

Design of Compact Magneto-Rheological Fluid Damper for Artificial Low-Limb Prosthesis (Magneto-Rheological Fluid를 이용한 인공지능 의족의 Compact damper 개발)

  • Sung, So-Young;Kang, S.J.;Moon, I.H.;Moon, M.S.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2962-2964
    • /
    • 2005
  • Magneto-Rheological (MR) fluid is suspension of fine magnetic particles in a liquid carrier such as silicon oil or water. MR fluid exhibits solid-like mechanical behavior into chain or clusters with high yield stress when magnetic field is applied to the particles. The response of MR fluids is very quick and reversible after removal of the field. MR Fluids have high yield stress (up to 5kPs) and operate in low voltage power supply. Recently, MR damper using MR fluids was open used in vibration control system such as structural devices, seat vibration controllers and helicopter rotor systems, but it is too big in size and heavy. Therefore, it is not appreciate to rehabilitation devices such as prosthetic limbs.

  • PDF

Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System (저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

Comparison of two controllers using IFAC 93 Benchmark Test (IFAC93 벤치마크 테스트를 통한 2개의 제어기 비교)

  • Baek, Seung-Uk;Yu, Chi-Hyung;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.617-619
    • /
    • 1998
  • A PID-controller is proposed as a controller to the IFAC93 benchmark process. It is compared with a Textbook PID-controller and a Derivative of output PID-controller. Especially, the Derivative of output PID controller works within the critical bounds of ${\pm}1.5$ except for 1 out of 15 periods at stress level 1,2. The objective of this paper, then, is to report on an alternative benchmark (IFAC93) and reveal more efficient PID controller between Textbook PID-control and Derivative of output PID-controller.

  • PDF

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.

The Influence of Job Demand, Shift, Work Environment and Stressors on the Railway Traffic Controller's Health (철도관제사의 직무요구, 교대근무, 과업환경 및 스트레스 요인이 건강에 미치는 영향)

  • Kim, Jung-Gon;Shin, Tack-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.73-80
    • /
    • 2016
  • This study highlights the main effect of job demand, work shift, work environment and stressors on the railway traffic controller's health, and the moderating effect of work0life balance. The result of empirical analysis based on questionnaires received from 328 traffic controllers working at 10 railway operating companies indicates that job demand, work shift, work environment and stressors have significant effect on their health, among which stressors is a major factor. In the respect of moderating effect, WLB showed no significance except for job demand. This result implies that controller's health can not be enhanced through their individual family or leisure life. Therefore, effective countermeasures and policy to mitigate their health problems and heal their symptoms are urgent.

Design and Analysis of a PLS of the Biped Walking RGO for a Trainning of Rehabilitation Considering Human Vibration(I) (인체진동을 고려한 재활훈련용 이족보행 RGO 보조기 PLS의 생체역학적 설계와 해석 (I);-인체진동 응력해석과 FEM을 중심으로 -)

  • 김명회;장대진;양현석;백윤수;박영필;박창일
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.10-18
    • /
    • 2003
  • This paper presented a design and control of a biped walking RGO(robotic gait orthosis) and its simulation. The biped walking RGO was distinguished from the other one by which had a very light-weight and a new RGO system will be made of 12-servo motors and 12-controllers. The vibration evaluation of the dynamic PLS(posterior leaf splint) on the biped walking RGO was used to access by the 3-axis accelerometer with a low frequency vibration of less than 30 Hz. The galt of the biped walking RGO depends on the constrains of mechanical kinematics and the initial posture. The stability of dynamic walking was investigated by analyzing the ZMP (zero moment point) of the biped walking RGO. It was designed according to the human wear type and was able to accomodate itself to the environments of S.C.I. Patients. The Joints of each leg were adopted with a good kinematic characteristics. To analyse joint kinematic properties. we made the strain stress analysis of the dynamic PLS and the analysis study of FEM with a dynamic PLS.

Review, Assessment, and Learning Lesson on How to Design a Spectroelectrochemical Experiment for the Molten Salt System

  • Killinger, Dimitris;Phongikaroon, Supathorn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.209-229
    • /
    • 2022
  • This work provided a review of three techniques-(1) spectrochemical, (2) electrochemical, and (3) spectroelectrochemical-for molten salt medias. A spectroelectrochemical system was designed by utilizing this information. Here, we designed a spectroelectrochemical cell (SEC) and calibrated temperature controllers, and performed initial tests to explore the system's capability limit. There were several issues and a redesign of the cell was accomplished. The modification of the design allowed us to assemble, align the system with the light sources, and successfully transferred the setup inside a controlled environment. A preliminary run was executed to obtain transmission and absorption background of NaCl-CaCl2 salt at 600℃. It shows that the quartz cuvette has high transmittance effects across all wavelengths and there were lower transmittance effects at the lower wavelength in the molten salt media. Despite a successful initial run, the quartz vessel was mated to the inner cavity of the SEC body. Moreover, there was shearing in the patch cord which resulted in damage to the fiber optic cable, deterioration of the SEC, corrosion in the connection of the cell body, and fiber optic damage. The next generation of the SEC should attach a high temperature fiber optic patch cords without introducing internal mechanical stress to the patch cord body. In addition, MACOR should be used as the cell body materials to prevent corrosion of the surface and avoid the mating issue and a use of an adapter from a manufacturer that combines the free beam to a fiber optic cable should be incorporated in the future design.

Effects of APU Noise on Employees on the Ramp (APU 소음이 램프 근로자들에게 미치는 영향)

  • Park, Sung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.720-725
    • /
    • 2016
  • This study examined how the APU noise of an aircraft influences the work efficiency and stress of airport ramp workers. A survey of airport ramp workers was conducted and the results analyzed. In the demographic analysis, men outnumbered women - accounting for 86% of the survey target - and 80% of the respondents were found to be employees with less than 15 years of work experience. The occupational cluster of the total of 160 respondents included 41 aircraft maintenance workers, 70 ground staff (Cargo, Water and Waste services), 19 ramp coordinators, 18 ramp controllers and 12 catering Service workers. The ground staff were the most prevalent, constituting 44% of the occupational cluster. Regarding the APU noise, 74% of the respondents answered that the environment was "always noisy", while 26% answered that it was "sometimes noisy". 85% answered that they are sensitive to and put under stress by the APU noise, while the majority of the respondents answered that the APU noise degrades their work efficiency. In conclusion, this study examined the effect of APU noise on the work efficiency and stress of airport ramp workers by analyzing the survey data by Regression and Chi-square analysis.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF