• Title/Summary/Keyword: Stress Based Evaluation

Search Result 867, Processing Time 0.037 seconds

Evaluation of MODIS NDVI for Drought Monitoring : Focused on Comparison of Drought Index (가뭄모니터링을 위한 MODIS NDVI의 활용성 평가: 가뭄지수와의 비교를 중심으로)

  • Park, Jung-Sool;Kim, Kyung-Tak
    • Spatial Information Research
    • /
    • v.17 no.1
    • /
    • pp.117-129
    • /
    • 2009
  • South Korea has been undergoing spring drought periodically and diverse researches using vegetation index have been carried out to monitor spring droughts. The strength of the vegetation index-based drought monitoring is that the monitoring method enables efficient spatio-temporal grasp of changes in drought events. According to the development of low resolution satellite images such as MODIS, which are characterized by outstanding temporal resolution, the use of the method is expected to increase. Drought analysis using vegetation index considered only meteorological factor as a cause that affects vitality of vegetation. But many indirect and direct factors affect vegetation stress, So many uncertainties are involved in such method of analysis. To secure objectivity of drought analysis that uses vegetation index it is therefore necessary to compare the method with most representative drought analysis tools that are used for drought management. In this study, PDSI and SPI which a meteorological drought index that quantifies drought and that is used as a basic index for drought monitoring and MODIS NDVI are compared to propose correlation among them and to show usefulness of drought assessment that uses vegetation index. This study shows changing patterns of NDVI and SPI 6-month are similar and correlation between NDVI and SPI was highest in inland vegetation cover.

  • PDF

Field Pullout Tests and Stability Evaluation of the Pretension Soil Nailing System (프리텐션 쏘일네일링 시스템의 현장인발시험 및 안정성 평가)

  • Kim, Hong-Taek;Choi, Young-Geun;Park, Si-Sam;Kim, Berm-Suk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.27-40
    • /
    • 2003
  • In the present study, a newly modified soil nailing technology named as the PSN(Pretension Soil Nailing) system is proposed. Effects of various factors related to the design of the pretension soil nailing system, such as the length of a sheathing pipe and the fixed cone, are examined throughout a series of the displacement-controlled field pull-out tests. 9 displacement-controlled field pull-out tests are performed in the present study and the pretension forces are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. A numerical approach is further made to determine a postulated failure surface as well as a minimum safety factors of the proposed PSN system using the shear strength reduction technique and the $FLAC^{2D}$ program. Global minimum safety factors and local safety factors at various excavation stages computed in case of the PSN system are analyzed throughout comparisons with the results expected in case of the general soil nailing system. An efficiency of the PSN system is also dealt with by analyzing the wall-facing deformations and the adjacent ground surface settlements.

  • PDF

Structural Strength Evaluation for Development of a Vertical Transfer Device for a Personal Rapid Transit (PRT) Vehicle (PRT 차량용 수직이송장치의 개발을 위한 구조강도 평가)

  • Kang, Seok-Won;Um, Ju-Hwan;Jeong, Rag-Gyo;Song, Joon-Hyun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.165-173
    • /
    • 2015
  • This paper presents numerical results of static structural stability analysis in development of a vertical transfer device of a PRT(Personal Rapid Transit) vehicle. The vertical transfer of a fully occupied vehicle operating on a road network is the first attempt, which is expected to contribute to overcome the limitations of conventional 2-dimensional operation mode. In particular, the vertical transfer apparatus designed based on vertical circulating conveyors is capable of continuous transfer without time delay so that it enables to accommodate a high traffic density. This system has been frequently used in a logistics field; however, it is essential to assess a structural integrity because an external force by a vehicle weight is exerted on the conveyors in the form of a concentrated load unlike a conventional logistic transport. In this study, prior to the production process, the structural performance of the pilot design in an early stage is numerically evaluated using the commercial finite element method (FEM) solver (i.e., $Ansys^{(R)}$).

Evaluation methods of shotcrete lining stresses considering steel rib capacities by two-dimensional numerical analysis (이차원 수치해석에 의한 강지보 성능을 고려한 숏크리트 라이닝의 부재력 평가 방법)

  • Ha, Tae-Wook;Kim, Dae-Young;Shin, Young-Wan;Yang, Hyung-Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.3
    • /
    • pp.269-282
    • /
    • 2008
  • In general, the effects of steel ribs are not considered in the numerical analysis of tunnel design. However, attempts have been increased recently to consider these effects in the analysis of shallow tunnels in soft ground, based on the fact that the steel ribs embedded in the shotcrete take a role to support some portion of the redistributed load due to excavation. In such analyses, the steel ribs can be considered in four different methods: (1) a conventional method where the steel ribs are not considered, (2) a method using the equivalent composite cross section in which the bending moment of shotcrete is not considered, (3) a method using the equivalent composite cross section in which both the compressive stress and the bending moment for the shotcrete and steel rib are considered, and (4) a method using beam elements for the shotcrete and the steel rib, respectively. These methods are adopted in the numerical analysis using FLAC 2D to investigate stresses of both the shotcrete and the steel rib. The overall results show that the analyses are more practical and economical when the effects of steel rib are considered fer the methods (2), (3), and (4). Since the results of those analyses considering steel rib capacity may be different according to the ground condition, it will be necessary to consider the appropriate method among them in accordance with design conditions.

  • PDF

The Shape and the Location of Forehead Hairline of Korean Males in Their 20s & 30s (20, 30대 한국 남성의 전두부 모발선의 모양과 위치)

  • Yoon, Sung-Won;Kim, Chung-Hun
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.295-299
    • /
    • 2011
  • Purpose: It is generally believed that alopecia is caused by various factors such as scars, stress, genetical factors, androgens, etc. Androgenic alopecia is one of the most common cause of alopecia and found mainly in males. Propecia (Merck & Co., USA) and Minoxidil (McNEIL-PPC, Inc, USA) were the drugs approved from FDA for treatment of androgenic alopecia. Surgical treatments such as flap, tissue expansion, scalp reduction and hair transplantation can be considered if necessary. Hair micrograft techniques were developed for natural hair shapes and minimal adverse effect. There were attempts to measure the length of the forehead of the Korean young adults. However attempts to classify the shape and location of forehead hairline were rare. This study attempted to find out standard hairlines of young adults in their 20s & 30s and the result would be the guideline of the hairline in hair replacement surgery of male patients in their 40s & 50s. Methods: 200 male adults in 20s and 30s were photographed and measured the length of 11 vertical index lines to determine hairline. The indexes are the distances from hairline to intercanthal midpoint (A), to medial canthus (B), to upper eyelid fissure (C), to lower eyelid fissure (D), to lateral canthus (E) and distance from lateral highest point to medial lowest point, if the hairline is M-shape (F). Additionally, we classified the hairlines into 4 groups, M, horizontal, inverted U and irregular shapes. Results: The most common hairline of male adults in their 20s is inverted U-shape (53.3%), followed by horizontal-shape, M-shape, irregular-shape. In their 30s, inverted U-shape (59%) is followed by irregular-shape, M-shape, horizontal-shape. The M-shape is more frequently found in males in 30s than those in 20s. The mean values of the indexes in their 20s are as follows: A (76.14 mm), B (Rt: 75.78 mm, Lt:76.41 mm), C (Rt: 69.43 mm, Lt: 69.92 mm), D (Rt: 76.92 mm, Lt:77.46 mm), E (Rt: 64.16 mm, Lt: 64.73 mm), F (4.09 mm). Those in their 30s are as follows: A (76.13 mm), B (Rt: 76.114 mm, Lt: 76.02 mm), C (Rt: 69.87 mm, Lt: 70.37 mm), D (Rt: 77.37 mm, Lt: 77.58 mm), E (Rt: 69.63 mm, Lt: 69.85 mm), F (6.14 mm). Conclusion: The knowledge about human body measurement is indispensable to plastic surgeons. In this study, inverted U shape is the most common type of hairline in 30s, and similar distribution is found in 20s. The percentage of M shape in their 30s is elevated more than 10% compared to that in their 20s. The study of hairline shapes and 11 indexes of hairlines can be useful for planning of the hair transplantation and postoperative evaluation. This study being based on photogrammetry, there may be differences between actual distance of curved face and projected distance on flat photographs.

Adhesive Performance and Fracture Toughness Evaluation of FRP-Reinforced Laminated Plate (FRP 보강적층판의 접착성능 및 파괴인성평가)

  • Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.868-875
    • /
    • 2015
  • In order to replace existing slit type steel plate on the wooden structure joint, the FRP-reinforced laminated plates were produced. Four types of FRP-reinforced laminated plates were produced according to the type of reinforcement and adhesive, and before applying to the joint, the adhesion performance test according to KSF 3021 and KSF 2160 and the Compact Tension (CT) type fracture toughness test specified in ASTM D5045-99 were carried out. As a result of adhesion performance test, all GFRP textile, GFRP sheet, and GFRP Textile-Sheet type FRP-reinforced laminated plates satisfied the requirement of soaking delamination percentage with smaller than 5% based on KS standard. However, aramid type specimen satisfied the standard as the soaking delamination percentage of 4.8% but it did not satisfied the standard as the water proof soaking delamination percentage of 70%. As a result of fracture toughness test, the volume ratio of reinforcement to timber became 23% so that the strength of FRP-reinforced laminated plates increased by two to four times in comparison to the control specimen. It was confirmed that the GFRP Textile-Sheet type specimen was most resistant to the fracture most since the ratio of stress intensity factor compared with that of the control increased to 61% owing to the parallel arrangement of glass fiber to the load. As a result of tensile shear strength test using FRP-reinforced laminated plates and nonmetal dowels, it is about 12% lower than metal connectors.

Seismic Evaluation of Beam-Column Joint Specimens of RC Special Moment Frames (철근콘크리트 특수모멘트골조의 보-기둥 접합부 실험체의 내진성능평가)

  • Lee, Ki-Hak;Seok, Keun-Yung;Jung, Chan-Woo;Shin, Young-Shik;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.85-93
    • /
    • 2008
  • This study summarizes the results of a research project aimed at investigating the inelastic rotation capacity of beam-column joints of reinforced concrete special moment frames. All of the test specimens were classified as special moment frame (SMF), based on the design and detailing requirements of the ACI 318-02 provisions. The acceptance criteria, originally defined for steel moment frame connections in the 1997 edition of the AISC Seismic provisions, were used to evaluate the beam-column joints of the reinforced concrete moment frames. A total of 39 test specimens were examined in detail. Most of the joints that satisfy the design requirements for special moment frame structures were found to be ductile up to a plastic rotation of 3% without any major degradation in strength. This is mainly due to the stringent ACI 318-02 requirements for special moment frame joints. The presence of transverse beams increases confinement and shear resistance of joints, which results in better performance than for joints without transverse beams. All of the SMF connections that satisfy the ACI 318-02 limitations on joint shear stress turned out to meet the acceptance criteria.

  • PDF

Evaluation of Fire Resistance of Unprotected Concrete-filled Rectangular Steel Tubular Columns under Axial Loading (재하가열시험에 의한 무내화피복 콘크리트충전 각형강관기둥의 내화성능평가)

  • Ahn, Jae Kwon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.323-334
    • /
    • 2014
  • In this paper, experimental program and associated numerical study were carried out to evaluate the fire resistance of unprotected concrete-filled rectangular steel tubular (CFT) columns subjected to the standard fire. The key testing parameters included the length effect, the load ratio, and the sectional dimensions of the CFT columns. Temperature distribution and axial deformation of the CFT column specimens were measured and analyzed. Rather early local buckling of steel tubes was observed in all the specimens. This caused subsequent load transfer from steel tube to concrete, and eventually triggered concrete crushing, or complete loss of the load bearing capacity of the column. This implies that the limit state of local buckling as well as overall flexural buckling should be incorporated in fire design procedure. As expected, the fire resistance time of specimen with higher load ratio consistently lessened. The prediction of fire resistance time of unprotected CFT columns based on the limiting steel temperature in current design codes or the formula proposed by previous studies is slightly conservative compared to the fire test results available. To establish the finite element analysis model that can be used to predict the thermal and structural behaviour of unprotected CFT columns in fire, the fully coupled thermal-stress analysis was also tried by using the commercial code ABAQUS. The numerical results showed a reasonable global correlation with the experimental results.

Cyclic Simple Shear Test Based Design Liquefaction Resistance Curve of Granular Soil (반복단순전단시험에 기반한 조립토의 설계 액상화 저항 곡선 개발)

  • Saeed-ullah, Jan Mandokhail;Park, Duhee;Kim, Hansup;Park, Ki-Chun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.6
    • /
    • pp.49-59
    • /
    • 2016
  • We develop liquefaction resistance curves, which represent the correlation between cyclic resistance ratio (CRR) and number of cycles (N) to estimate the build-up of residual excess pore pressure from simple shear tests performed for this study and also from published literature. The liquefaction curve is calculated from two models. The comparisons show that one of the models is not reliable because it underestimates CRR. The scatter of the data is shown to be significantly reduced when CRR is normalized to the resistance ratio at N = 15 ($CRR_{N=15}$). Use of the normalization is particularly useful because CRR can be easily estimated from field tests. From normalization, we propose mean, upper, and lower curves. The corresponding design equation and its parameters are also proposed. We believe that the proposed curves can be used for effective stress site response analyses and evaluation of the seismic performance of port structures.

Evaluation of the Stability of Geomembrane Liner System in Closed Waste Landfill (사용종료 폐기물 매립장의 멤브레인 차수시스템 안정성 평가)

  • Lee, Heung-Gil;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Recently, the effective use of closed waste landfill nearby urban areas has been demanded, because of the lack of the usable land. However, the reuse of closed landfill is needed an adequate stabilization of liner system. But most of these places are consisted of steep slope and hence it is necessary to use the geosynthetics liners in there. Liner system of waste landfills is an important facility which prevents leachate outgoing from the landfills and also groundwater infiltrating from surroundings into the landfills. During the waste disposal stage, differential settlement and tensile stress of the geosynthetic materials could occur due to impact load of trucks and dozers, waste loads and weak foundation soils. In this study, the tensile strength and tracer test were performed to evaluate the stability of geomembrane liner systems. Based on the tensile strength test result of in-situ geomembrane sample, the yield tensile strength maintain the suitable strength by specification and current law. However, according to the tracer test, the damage of geomembrane liner was detected on sanitary landfill section.

  • PDF