• 제목/요약/키워드: Strength test

검색결과 13,651건 처리시간 0.043초

FRP 복합체의 콘크리트에 대한 접착강도 시험방법 변수 연구 (Parametric Study on Test Method for Pull-off Strength of FRP Composite Material used in Strengthening RC Members)

  • 최기선;유영찬;이한승;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.222-225
    • /
    • 2006
  • Pull-off test is widely used to evaluate bond performance between concrete and FRP composite. However, reliability of experiment result declines due to many difference between test methods of each national standards. This study analyzed problems of various existing test methods for pull-off test and suggested standardized test method. In addition, since tensile strength of concrete is smaller than bond strength of epoxy resin, maximum bond strength of epoxy resin shall be limited within tensile strength of concrete. Alternative testing method, therefore, which decrease FRP adhesion areas than concrete adhesion areas is suggested to widen test range of bond strength in pull-off test. In the experimental results, bond performance can be estimated up to two times of tensile strength of concrete by reducing FRP adhesion areas by 1/3.

  • PDF

보온재를 사용한 고강도 매스 콘크리트의 품질관리에 관한 연구 (An Experimental Study on Quality Management of Strength in High Strength Mass Concrete Structure Using Thermal Insulation Material)

  • 조규현;백민수;김성식;임남기;이영도
    • 한국건축시공학회지
    • /
    • 제4권2호
    • /
    • pp.113-118
    • /
    • 2004
  • This study is a basic experiment on quality management of the compression strength of high strength concrete, aiming. at quality management of high strength mass concrete by giving the temperature hysteresis of the mass test pieces to managerial test pieces. Different from ordinary concrete, high strength concrete generally shows the temperature high rising caused by hydration heat inside the concrete. It is known that, in mass concrete, thermal stress occurs due to the difference in temperature between the inside and the outside, which causes a significant difference in compression strength between structure beams and managerial test pieces. It is also reported that there is a large difference between the compression strength of cylindrical managerial test pieces of standard underwater curing and the strength of structure beam concrete. Thus, this study made concrete test pieces in an optimal mix ratio for each strength level, and also created thermal insulation curing box and managerial test pieces. Then it carried out comparative analysis in relation to core strength and suggested equipment and a technique that can control the strength of high strength concrete mass more conveniently and accurately.

An Experimental Study on the Fracture Strength of Steel Fiber Reinforced Concrete

  • Chai, Won-Kyu
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.19-21
    • /
    • 2012
  • In this thesis, fracture test was performed in order to investigate the fracture strength of SFRC(steel fiber reinforced concrete) structures. The relationship between the compressive force and strain value of SFRC specimens were observed under the compressive strength test. From the fracture test results, the relationship between percentage of fiber by volume, compressive strength, elastic modulus, and tensile strength of SFRC beams were studied, and the measured elastic modulus of SFRC were compared with the calculated elastic modulus by ACI committee 544.

Double-Punch Test에 의한 콘크리트의 인장강도 시험에 관한 연구 (A Study on Double - Punch Test for Tensile Strength of Concrete)

  • 이우종;고재군
    • 한국농공학회지
    • /
    • 제30권2호
    • /
    • pp.82-94
    • /
    • 1988
  • The purpose of this study is to introduce the Double Punch test method which is an indirect testing method of tensile strength of concrete, and to compare with the tensile strength of concrete as determined by the split-cylinder test, a practical method for performing the Double Punch test to obtain the tensile strength of concrete is proposed and recommended for general use. In this study, the dimensions of cylindrical specimens used in the Double-Punch test were 15X30cm, 15X15cm, 10${\times}$(20cm, and 5${\times}$l0cm, and in the split-cylinder test were 15${\times}$(30cm, 15${\times}$(15cm, and 10${\times}$(20cm. And the diameters of loading punches used in the Double-Punch test were 1.5cm, 2.5cm, and 3.5 cm. The results obtained from tests are summarized as follows ; 1. In the split-cylinder test, the tensile strength of concrete by the linear elasticity theory is similar to that of plasticity theory. 2. Both split-cylinder test and Double-Punch test, tensile strength of concrete is increased with decreasing specimen size. This tendency is identical when the ratio of specimen diameter to height is 1: 2, but that tendency is quite different when the ratio is 1: 3. In the Double-Punch test, if specimen size is constant, by increasing the punch size, tensile strength of concrete is increased, too. 4. Using a 15 ${\times}$( 15 cm cylinder specimen and 3.5 cm diameter punch in the Double Punch test would give the most uniform and consistent result in tensile strength, and the result showed a gQod correlation with splitting tensile strength from 15 x 30cm specimen. 5. In order to obtain satisfactory results and to nuninuze variability, it is proposed that specimens of 15 cm in diameter and 15 cm in height with two 3.5 cm diameter punches should be used. It seems, therefore, reasonable tt) take f't=0.0024 P(kg / cm$^2$) as a working formula for computing the tensile strength in the Double Punch test for concrete.

  • PDF

단열양생을 이용한 고강도 콘크리트 압축강도 추정에 관한 실험적 연구 (An Experimental Study on Estimation of Strength in High Strength Concrete Structure Using Simple Adiabatic Curing)

  • 조규현;김제섭;황병준;공민호;백민수;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.450-453
    • /
    • 2004
  • The present study is a basic experiment on the estimation of the compression strength of high strength concrete, aiming at estimating the compression strength of mass test pieces of high strength concrete by giving the temperature hysteresis of the mass test pieces to managerial test pieces. Thus, this study made concrete test pieces in an optimal mix ratio for each strength level, and also created adiabatic curing tank and managerial test pieces. Then it carried out comparative analysis in relation to core strength and suggested equipment and a technique that can control the strength of high strength concrete mass more conveniently and accurately.

  • PDF

고지재생연구(제14조) -고온압착건조처리 골판지 원지의 강도에 미치는 양성 PAM과 미세분의 영향- (Recycling of Wastepaper(XIV) -The Effect of Amphoteric PAM and Fines on the Dry Strength Properties of Condebelt Press Dried Linerboards-)

  • 최병수;윤혜정;류정용;신종호;송봉근
    • 펄프종이기술
    • /
    • 제33권2호
    • /
    • pp.24-31
    • /
    • 2001
  • As a novel method to improve strength properties of recycled test liner, Condebelt press drying system was introduced and adopted into Korea. New press drying treatment could enhance the surface and strength properties in accordance with the increase of sheet density. However, Condebelt drying can not increase the density of repeatedly recycled test liner as much as that of virgin UKP and at the same density condition, the strength of Condebelt press dried UKP is greater than that of press dried test liner. In order to increase the strength of test liner, two attempts were tried in this study. First, addition of polyelectrolytes, dry strength agent was investigated with a view to promote the fiber bonding potential of reclaimed corrugated container pulp. Second, blending effect of fines were analyzed in an aims of increasing density and strength of test liner. The results were as follows; Even in the case of test liner densified by Condebelt press dryer, addition of amphoteric PAM as a dry strength agent was effective in increasing strength properties and so the effect of dry strength agent on improving bonding potential of recycled OCC fiber could be confirmed. As an appropriate addition level of amphoteric PAM, below 1% based on dry pulp weight was suggested. Different from virgin UKP, density of recycled test liner can be increased by the blending of OCC fines and strength properties also can be improved. However, excessive blending of OCC fines could result in decreasing of density and serious weakening of test liner. The best blending ration of fines in test liner can be determined as about 30%. Taking into account the fines content in general OCC pulp as 50%, excessive 20% of fines were supposed to be fractionated and removed in order to achieve the best strength of Condebelt press dried test liner.

  • PDF

콘크리트 직접인장강도의 세장비 효과 (Effect of Aspect Ratio in Direct Tensile Strength of Concrete)

  • 홍건호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.246-253
    • /
    • 2003
  • 콘크리트 부재는 직접 인장력에 저항하도록 설계되지는 않는 것이 일반적이나, 부재의 균열강도 등을 산정하기 위해서는 반드시 확인하여야 하는 재료 특성 중의 하나이다. 콘크리트의 인장강도 시험방법은 주로 직접인장, 휨인장, 쪼갬인장의 3가지로 구분하고 있으나, 이 중 직접인장시험법은 시험체에 순수인장력을 가력할 수 있는 실험방법상의 문제로 거의 수행되지 못하여 온 것이 사실이다. 본 연구에서는 직접인장시험방법의 검토 및 시험체의 세장비, 크기 등이 직접인장강도에 미치는 영향에 대하여 연구하였다. 단부 보강편을 이용한 직접인장강도의 실험은 RILEM 및 U.S.Bureau of Reclamation의 규정을 사용하였으며, 총 4가지 종류의 세장비와 2가지 크기의 시험체에 대한 연구를 수행하였다. 실험의 결과는 동일변수의 쪼갬인장강도 및 휨인장강도와 비교$.$분석을 실시하였으며, 이를 신뢰성있는 선행 연구자들의 연구결과와 비교하여 그 타당성을 검증하였다.

가스터빈 블레이드 재질 Inconel 738LC의 소형펀치시험 거동에 관한 연구 (A Study on the Small Punch Test Behaviors of Gas Turbine Blades Material Inconel 738LC)

  • 장성호;유근봉;최기순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.193-198
    • /
    • 2000
  • The small punch test have been developed to evaluate the material strength of the power plant components. This small punch test specimen is very small than the conventional strength test specimens. Korea Electric Power Research Institute (KEPRI) have been applying this test to assess accurately the life of thermal power plant and enhancing the reliability. The small punch test for gas turbine blades is under development. It's possible to compare the relative strength among the same materials having different operation histories. In this paper, the strength reductions of gas turbine materials are investigated by the small punch tests. All materials shows the almost same strength and deformation with the allowable deviation. At the same test temperature, the damaged material has the maximum load value. The strength reduction is not shown in this small punch test results.

  • PDF

구조체 콘크리트에 접합분리 시험체의 적용을 위한 강도비교에 관한 실험적 연구 (Studies on the Evaluation Method of Strength Comparison for Application in Joint Separation Test Body to Structural Concrete)

  • 김성덕;이선호;정광식;백민수;이영도;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.79-82
    • /
    • 2008
  • It has been reported that destruction test by core collection is the most reliable of the structural concrete strength in present building construction field. But it causes low efficiency by damage and cutting in structure due to the core collection. It also has some problems in repairing. Additionally in case of strength test with management specimen, different environment compared to the structure environment cause problems about estimation precise structure strength. Therefore, it is required to develop structure direct strength test that has test values and credibility above the ones obtained by core specimen collection strength test and seasonal specimen test to suggest a reasonable and practical management method of structural concrete.

  • PDF

노후아파트 현장에서의 콘크리트 압축강도 추정 (Concrete Compressive Strength Prediction from Deteriorating Apartment Site)

  • 이규동;임홍철;임병호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.155-158
    • /
    • 2006
  • Deduction of compressive strength in concrete members is very important to decide stability of structures. In this study, we compare the compressive strength of concrete between nondestructive test done to the building which was to be demolished at residential reconstruction site and destructive test of core specimen from the site. The result is more reliable because ore can compare the measurement of nondestructive tell with the result from destructive test using drilled cores. Compressive strength of each material was calculated with the result of rebound number test. In addition, we performed ultrasonic test for another result of compressive strength. And we made a comparative study of compressive strength of concrete drawn from both nondestructive and destructive tests.

  • PDF