• Title/Summary/Keyword: Strength retention

Search Result 384, Processing Time 0.026 seconds

Photo-Degradation Behavior of Silk Fabrics (견직물의 광열화 거동)

  • Lee, Hack-Jung;Kwon, Young-Suk;Jang, Jeong-Dae;Lee, Sang-Joon;Cho, Hyun-Hok
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.37-42
    • /
    • 2006
  • Researches to preserve and restore the remaining fabrics as costume heritages have been carried out. In this study, in order to artificially restore an excavated silk fabrics, degummed silk fabrics and safflower dyed silk fabrics were prepared for an experiment. These fabrics were photo-degraded by the Xenon arc beam to have various strength retention(100%, 80%, 60%, 40%, 20%). The fine structure and physical properties of Xenon arc treated fabrics were investigated with various techniques such as tensile test, weight loss, wide-angle X-ray diffraction, yellowness, color, SEM etc. Tensile strength and the crystal diffraction intensity of silk fabrics decreased as Xenon arc hem treatment time increased. Weight loss increased slightly. Strength retention was decreased as the Xenon arc beam treatment time goes by. (Yellowness of the undyed silk fabrics and $L^*$ of the dyed silk fabrics increased. Whiteness of the undyed silk fabrics and $b^* of the dyed silk fabrics decreased.) SEM results of the silk fabrics treated Xenon arc beam show that surface was a little damaged.

Improvement of Wet-end Performance and Paper Strength with Polyvinylamine

  • Son, Dong-Jin;Kim, Bong-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.5 s.113
    • /
    • pp.63-69
    • /
    • 2005
  • This study was performed to introduce recently developed polyvinylamine as a wet-end process and paper strength improving aids. As a retention and drainage aids, high cationic charged polyvinylamine was more effective at the BCTMP and ONP stock condition than LBKP stock condition. As a dry tensile strength aid, dual system of polyvinylamine with anionic polyacrylamide was the best at the LBKP or ONP stock conditions. On the other hand, polyvinyl amine alone was better than dual system of polyvinylamine with anionic polyacrylamide at the BCTMP condition. As a wet tensile strength aid, polyvinylamine single system and dual system of polyvinylamine with anionic polyacrylamide were good at LBKP, BCTMP and ONP stock conditions. However, poly(aminoamide)-epichlorohydrin resin was good at LBKP and ONP stock conditions but efficiency of poly(aminoamide)-epichlorohydrin resin was remarkably decreased at BCTMP stock condition.

Analysis of Water Retention Capacity at Sasa borealis Stands in Jirisan National Park (지리산국립공원 내 조릿대 임분의 수원함양기능 분석)

  • Ji, Hyung Woo;Park, Jae Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.3
    • /
    • pp.1-11
    • /
    • 2008
  • Although landslides were frequently occurred under Tripterygium regelii and Rubus sp. vegetations, the damage of landslide was not observed in sasa (Sasa borealis) stands. These phenomena may be affected by forest vegetation types. This result suggested that the landslide occurred in Jirisan (Mt.) National Park may be closely related to water retention capacity at Sasa borealis stands. This study compared and analyzed the water retention capacity of each soil horizon of sasa, larch (Larix leptolepis) and mongolian oak (Quercus mongorica) stands. Soil bulk density in A horizon was lower in sasa (0.776g/$cm^3$) than in mongolian oak (0.828g/$cm^3$) and in larch stands (1.282g/$cm^3$). Water permeability in A horizon was 0.02055cm/sec for sasa, 0.00575cm/sec for mongolian oak, and 0.0007cm/sec for larch stands, respectively. The water permeability of sasa stand was about 3.6 times and about 29 times higher than in mongolian oak and in larch stands, respectively. This result indicates that water infiltration of soil surface during a rain event is more rapid in sasa than in other two stands. Soil organic matter content in B horizon was lower in larch (0.7%) than in mongolian oak (6.5%) and in Sasa (3.3%) stands. The solid ratio in A horizon was highest in larch among three stands, but that of mongolian oak and larch stands showed a similar rate. Pore space rates was 70.7% for A horizon and 70.6% for B horizon of sasa, 68.9% for A horizon and 70.6% for B horizon of sasa, 68.9% for A horizon and 70.6% for B horizon of mongolian oak forests and 51.7% for A horizon and 49.2% for B horizon of larch forests, respectively. According to pore space rates, the water retention capacity may be poor in larch stand compared with other two stands. Soil strength in sasa and mongolian stands was over 25kgf/$cm^2$ from 40cm depth, while the strength was over 25kgf/$cm^2$ from 25cm depth in larch stand. The result indicates that tree growth and water permeability in larch stand could be limited due to high soil strength. Larch stand was poor for soil pore space development to be offered to the water retention capacity, but water retention capacity of A horizon soil in sasa stand was high than that of other two stands. Therefore, establishment of sasa stand under larch stand could help to prevent landslides.

Fluidity Retention of Cement-Based Composites Using High range water reducing AE agent (고성능AE감수재를 사용한 시멘트복합체의 유동성 유지성능)

  • 김기형;김인수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.93-98
    • /
    • 1998
  • Fluidity retention of concrete used high range water reducing AE agent(HWAE) is varied according to type, dosage amount and dosing method of HWAE. The type and substitution ratio of mineral admixture also have influence on the fluidity retention of concrete using HWAE. For the purpose of improving the fluidity retention in concrete used HWAE, 3 types of HWAE and ground granulated blast furnace slag(SG) are applied in cement-based composites such as cement paste, mortar and concrete respectively. According to using the HWAE of naphthalene sulfonates and SG, the fluidity retention of mortar and concerete is improving the fluidity retention and strength of concrete regardless of type of HWAE.

  • PDF

Unsaturated Effective Stress Based on Water Retention Characteristics for Triaxial Tests of Silty Sand (실트질 사질토의 삼축시험 시 함수특성에 따른 불포화 유효응력)

  • Lee, Younghuy;Oh, Seboong;Baek, Seungcheol;Kim, Sangmin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Suction stress is evaluated from soil water retention curves in order to deduce effective stress in unsaturated soils. $K_0$ consolidated triaxial tests were performed for silty sand to interpret effective stress in consolidation and shearing of unsaturated soils. Suction stresses from both consolidation stress and shear strength in triaxial tests were compared with those from soil water retention curves. The effective stresses on consolidation and shear strength are on each unique line, which are the same as that of the saturated case. It was found that the effective stress from soil water retention curves agrees with those from consolidation and shear strength in triaxial tests.

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Comparison of Geotechnical Characteristics of Bottom Ash for Lightweight Fill Material (경량 성토재 활용을 위한 석탄 저회 물성 비교)

  • Kim, Yun-Ki;Lee, Sung-Jin;Shin, Min-Ho;Lee, Seung-Rae;Lee, Yong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.679-686
    • /
    • 2010
  • Mechanical characteristics of bottom ash produced in coal-fired power plant are investigated to utilize as light-weight fill materials. Triaxial compression test, water retention test, and unsaturated direct shear test were conducted for weathered soil (WS), reclaimed bottom ash (RBA), and screened bottom ash (BA). RBA had larger frictional angle and lower effective cohesion than those of WS. Water retention charactersitics of RBA and BA existed within distributions of soil-water characteristic curves for domestic weathered soils. Unsaturated shear strength of RBA was similar to that of WS at matric suctions of 50 kPa and 100 kPa. As a conclusion, bottom ash can be used as fill materials to replace the conventional construction materials by.

  • PDF

The Influence of Viscosity Agent on Non-Segregation Property in Underwater Concrete (수중 콘크리트의 분리 저항성에 미치는 중점제의 영향)

  • 김선만;김영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.117-122
    • /
    • 1996
  • The purpose of this study is to investigate the properties of underwater concrete using three kinds of cellulose ether which has viscosity and water retention. The result is that water retention in underwater concrete shows in inverse proportion to PH value and the compressive strength is almostly effected by water retention. It can be certificated by the zeta electro potential value of an undispersed underwater concrete.

  • PDF

Evaluation Retention Performance of Phosphate-introduced Chemical Admixture Mortar in Extremly Hot Weather Condition (극서환경용 포스페이트 도입 화학혼화제 모르타르 특성 평가)

  • Ki, Jun-Do;Kim, Kwang-Ki;Kim, Jung-Jin;Park, Soon-Jeon;Kim, Jung-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.96-97
    • /
    • 2017
  • Performances such as retention, setting time and strength generation of mortar with phosphate-introduced chemical admixture, domestic and foreign admixtures are evaluated to find one that meets over 3 hours retention in extremly hot weather condition in this study.

  • PDF

Case Study on the Design of Earth Retaining and Retention Wall Using Pre-casted Concreted Pile(PHC) (기성콘크리트말뚝(PHC)을 이용한 옹벽겸용 흙막이설계사례)

  • Han, Jung-Geun;Cho, Young-Ryang;Kim, Sang-Kwi;Park, Sang-Cheol;Eo, Yun-Won
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.3
    • /
    • pp.33-42
    • /
    • 2005
  • The bearing methods using pile of steel itself or reinforced concrete has been applying which in excavated depth was not deep. Also, the retaining wall as resisting structure to lateral force has taken weakness that the cure periods of concreted is long. Recently, with the material cost of steel, the application of cement is more increasing trend. In this study, the design methods of earth retaining and retention wall within the pre-casted concrete pile, PHC(Pretentioned spun High strength Concrete piles), was proposed which in the ground condition of excavated depth was not deep. The typical ground conditions, cohesive and non-cohesive soil, was considered as follows; soil strength as internal friction angle and UU(Undrained Unconsolidation triaxial test) strength, soil reaction and stabilization of structures. The application of design methods could be confirmed through the comparing and analyzing between measured data and utility software for the design.