• Title/Summary/Keyword: Strength Ratio

Search Result 7,448, Processing Time 0.064 seconds

Post buckling mechanics and strength of cold-formed steel columns exhibiting Local-Distortional interaction mode failure

  • Muthuraj, Hareesh;Sekar, S.K.;Mahendran, Mahen;Deepak, O.P.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.621-640
    • /
    • 2017
  • This paper reports the numerical investigation conducted to study the influence of Local-Distortional (L-D) interaction mode buckling on post buckling strength erosion in fixed ended lipped channel cold formed steel columns. This investigation comprises of 81 column sections with various geometries and yield stresses that are carefully chosen to cover wide range of strength related parametric ratios like (i) distortional to local critical buckling stress ratio ($0.91{\leq}F_{CRD}/F_{CRL}{\leq}4.05$) (ii) non dimensional local slenderness ratio ($0.88{\leq}{\lambda}_L{\leq}3.54$) (iii) non-dimensional distortional slenderness ratio ($0.68{\leq}{\lambda}_D{\leq}3.23$) and (iv) yield to non-critical buckling stress ratio (0.45 to 10.4). The numerical investigation is carried out by conducting linear and non-linear shell finite element analysis (SFEA) using ABAQUS software. The non-linear SFEA includes both geometry and material non-linearity. The numerical results obtained are deeply analysed to understand the post buckling mechanics, failure modes and ultimate strength that are influenced by L-D interaction with respect to strength related parametric ratios. The ultimate strength data obtained from numerical analysis are compared with (i) the experimental tests data concerning L-D interaction mode buckling reported by other researchers (ii) column strength predicted by Direct Strength Method (DSM) column strength curves for local and distortional buckling specified in AISI S-100 (iii) strength predicted by available DSM based approaches that includes L-D interaction mode failure. The role of flange width to web depth ratio on post buckling strength erosion is reported. Then the paper concludes with merits and limitations of codified DSM and available DSM based approaches on accurate failure strength prediction.

Hip Muscle Strength and Ratio Differences in Delivery Workers With and Without Iliotibial Band Syndrome

  • Eun-su Lee;Ui-jae Hwang;Hwa-ik Yoo;Il-kyu Ahn;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.30 no.1
    • /
    • pp.15-22
    • /
    • 2023
  • Background: Delivery workers repeatedly get in and out of trucks and walk or run to deliver packages during work. Iliotibial band syndrome (ITBS) is a well-known non-traumatic overuse injury of the lateral side of the knee caused by frequent knee flexion and extension. Hip muscle strength is among the factors that prevent lower extremity injuries. Although many studies have examined the relationship between ITBS and hip muscle strengths, there was no study comparing hip muscle strength and ratio between delivery workers with and without ITBS. Objects: This study aimed to compare hip muscle strength and hip internal/external rotator and adductor/abductor strength ratios between delivery workers with and without ITBS. Methods: Fourteen delivery workers with ITBS matched inclusion criteria in the present study among 20 participants. Because total sample size was required 28 subjects by G*power program (ver. 3.1.9.4; University of Trier), 14 delivery workers without ITBS were recruited. Hip muscle strengths were measured in a side-lying position using a Smart KEMA pulling sensor (KOREATECH Co. Ltd.). An independent t-test was used to compare hip muscle strengths and hip internal/external rotator and hip adductor/abductor strength ratios between delivery workers with and without ITBS. Results: The adductor/abductor strength ratio was significantly greater in delivery workers without ITBS than in those with ITBS (p < 0.05). The strengths of the hip abductor, hip adductor, hip internal rotator, hip external rotator, and the ratio of internal/external rotator strengths were not significantly different between the delivery workers with and without ITBS (p > 0.05). Conclusion: This study's findings showed that delivery workers with ITBS had significantly lesser adductor/abductor strength ratio, while the strengths of the hip abductor and adductor muscles did not differ significantly. These results suggest that adductor/abductor strength ratio should be considered when evaluating and treating ITBS in delivery workers.

Evaluation of Physical Properties according to Mixing Ratio and the Survey of the Current Situation for Epoxy Resin used in Conservation (문화재 보존처리에 사용되는 에폭시수지의 사용현황과 배합비율에 따른 물성 변화 연구)

  • Lee, Eun Ji;Jang, Sung Yoon
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.223-234
    • /
    • 2016
  • Two-component epoxy resin is widely used in the cultural heritage restoration field. However according to mixing ratio of resin and hardener, curing property, mechanical strength and chemical structure differ which have possibility to effect the stability of cultural heritage. Result of questionnaire survey shows hands-on workers in the conservation field tend to mix the epoxy resin with his or her eye measurement when the using amount is small or mix additional hardener to shorten the pot life of epoxy resin. This research aims to analyze the curing property, mechanical strength and chemical structure of rapid curing type epoxy resin and medium curing type one depending on relative ratio of 0.25~4 of hardener to resin. When the amount of hardener was 0.5~2 times more than the resin, exothermic heat and curing speed were both increased. In case of included hardener to resin was lower than official ratio, mechanical strength (tensile shear strength, tensile strength and compressive strength) became higher along with active cross-linking bonding of the epoxy resin. Medium curing type epoxy relatively had lower exothermic heat and slower reaction during curing process. It was observed to be put to definite point of mechanical strength under lower content of hardener than official ratio. While, hardener ratio more than twice the resin slowed down the curing greatly and lowered the adhesion strength also. In conclusion, under the lower mixing rate of hardener than official ratio would show relatively fast reaction with similar mechanical strength. Over the official ratio on the other hand, material property drops rapidly. Accordingly, mixing ratio of epoxy resin is expected to be influential to the stability of cultural heritage.

Seismic Performance and Flexural Over-strength of Circular RC Column (원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.49-58
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).

A Study on Shear Capacity of High Strength Lightweight Reinforced Concrete T-Beams (고강도 경량콘크리트를 사용한 철근콘크리트 T 형보의 전단성능)

  • 김진수;김원호;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.220-225
    • /
    • 1993
  • This paper is an experimental study on shear capacity of the high strength lightweight reinforced concrete beams with shear-depth ratio between 1.5 and 2.5. Thirteen T & rectangular beams were tested to determine their diagonal cracking and ultimate shear capacity. The major variables are shear span-depth ratio (a/d=1.5, 2.0, 2.5), concrete compressive strength(f'c=210, 24., 270㎏/㎠) and tensile steel ratio( =0.6, 1.2%). Based on results obtained from experiment of high strength lightweight reinforced concrete Beam & normal concrete, the following conclusions were drawn. (1) The shear capacity of high-strength lightweight concrete is less 15% than that of normal concrete under same condition. (2) As the results of Comparing this experimental datas with other various formulas. It is regarded that ACI 318-89 shear strength formula related tensile strength is proper to design formula of shear strength of high-strength lightweight reinforced concrete using lightweight concrete.

  • PDF

An Experimental Study on Failure Modes of High Strength Reinforced Concrete Columns (고강도 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구)

  • 최창익;박동규;손혁수;김준범;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.442-445
    • /
    • 1997
  • With increasing use of high strength concrete tied columns in structural engineering, it becomes necessary to examine the applicability of related sections of current design codes. High strength concrete has an advantage of strength capacity and stiffness especially for column elements. This paper presents an experimental study of high strength concrete tied columns subjected to eccentric loading. The main variables included in this test were concrete compressive strength, steel amount, eccentricity, and slenderness ratio. The concrete compressive strength varied from 34.9Mpa(356kg/$\textrm{cm}^2$ ) to 93.2Mpa(951kg/$\textrm{cm}^2$ ) and the longitudinal steel ratios were between 1.1% and 5.5%. The eccentricity was selected for the different failure modes, i.e., compression control, balanced point, and tension control. The slenderness ratio varied from 19 to 61. The column specimens with same slenderness ratio but with different concrete compressive strength were constructed and tested. The purpose of this paper is to show failure modes of high strength reinforced concrete columns.

  • PDF

Foundamental Properties of High Strength Concrete Using Silica Fume (실리카흄을 이용한 고강도 콘크리트의 기초적 성질)

  • 곽기주;이경동;곽동림
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.83-92
    • /
    • 1997
  • An experimental study of the application of Silica fume for the high strength concrete was conducted. Nine specimens with three different contents of silica fume, 0%, 10%, 20% and with three water-cement ratio 30%, 40%, 50% were tested. Results shows that 10% of silica fume and 30% of water-cement ratio has a maximum strength with 700kg/$cm^2$ of compressive strength and 64kg/$cm^2$ of splitting tensile strength and 100kg/$cm^2$ of flexural strength. Slump value of the tested samples decreases with increasing water-cement ratio and elapsed time of silica fume. Splitting tensile strength$({\sigma}_f)$ and flexural strength $({\sigma}_f)$ and static modulus of elasticity(E) can be correlated with compressive strength $({\sigma}_c)$ from a regression analysis.

  • PDF

Shear Capacity of Higth-Strength Concrete Beams With a Shear Span-Depth Ratio Between 1.5 and 2.5 (전단-스팬비가 작은 고강도철근콘크리트 보의 전단성능)

  • 문정일;안종문;김대근;이광수;이승훈;오정근;장일영;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.106-110
    • /
    • 1992
  • This paper is an experimental study on shear capacity of the high strength R/C beams with a shear span-depth ratio between 1.5 and 2.5. a total of 15 beams was tested to determine diagonal cracking and ultimate shear strength. The major variables are shear span-depth ratio (a/d=1.5, 2.0. 2.5) , vertical shear reinforcements ratio(Vs = 0 , 25, 50, 75, 100% ( Vs = Pv/Pv(ACI)), and concrete compressive strength (f'c= 747㎏/㎠). Test results indicate that ACI 318-89 Eq(11-31) generally underestimates shear strength carried by vertical shear reinforcements, and the mode of failure may change from shear tension to shear compression for the beams having higher Vs than 75%, thus the effectiveness of r-fy on ultimate shear strength (vu) decreased.

  • PDF

A Strength Properties According to Water cement ratio using Oyster shell as Aggregate (굴 패각을 잔골재로 사용한 모르타르의 물시멘트비에 따른 강도특성)

  • Jung, Ui-In;Choi, In-Kwon;Heo, Min-Hoe;Kim, Bong-Joo;Won, Chul-Hee;Choi, Ho-Rim
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.154-155
    • /
    • 2016
  • Oyster shell is light weighted and its strength characteristic is similar to sand. So we produced mortar test piece using grounded oyster shell powder under 0.5mm, which is a standard of fine aggregate, and reviewed strength properties according to water cement ratio. In our test, we used two kinds of oyster shell particles: below 0.6mm and 1.2~2.5mm. Water cement ratio is varied 40% to 100% and we found that flexural strength and compressive strength are decreased in higher water cement ratio.

  • PDF

Early Strength and Properties of EVA Powder Modified High Strength Concrete (EVA Powder 개질 고강도 콘크리트의 초기강도 및 수밀특성)

  • Kim, Young-Ik;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.123-127
    • /
    • 2005
  • EVA Powder modified high strength concretes were prepared by varying polymer/binder mass ratio with a constant water/binder mass ratio of 0.3. The effect of EVA powder on the slump, hydration heat, compressive and flexural strength, toughness and water absorption ratio was studied. In hydration heat test, temperature of hydration reaction displayed almost fixed level regardless of containing rate of EVA powder, but peak time of hydration reaction displayed late inclination as containing rate of powder increases. With the same water/binder mass ratio, the compressive strength and water absorption of EVA powder modified concretes decreased slightly when EVA powder was added and the flexural strength of EVA powder modified concretes rised slightly when EVA powder was added. Also, the toughness of the modified concretes can be improved markedly. The interpenetrating structure between the polymeric phase and cement hydrates formed at a $2{\sim}6%$(containing rate of EVA powder). The properties of the polymer modified concretes were influenced by the polymer film, cement hydrates and the combined structure between the organic and inorganic phases.

  • PDF