• 제목/요약/키워드: Street temperature

검색결과 82건 처리시간 0.024초

도시 협곡에서 건물 지붕 냉각이 스칼라 물질 확산에 미치는 영향 (Effects of Building-roof Cooling on Scalar Dispersion in Urban Street Canyons)

  • 박수진;김재진
    • 대기
    • /
    • 제24권3호
    • /
    • pp.331-341
    • /
    • 2014
  • In this study, the effects of building-roof cooling on scalar dispersion in three-dimensional street canyons are investigated using a computational fluid dynamics (CFD) model. For this, surface temperature of building roof is systematically changed and non-reactive pollutants are released from street bottom in urban street canyons with the aspect ratio of 1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the control experiment are analyzed first. Then, the effects of building-roof cooling are investigated by comparing the results with those in the control experiment. In the control experiment, a portal vortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon, because warmer air is coming into the street canyon from the roof level. However, air temperature near the street bottom is lower inside the street canyon due to the inflow of cooler air from both sides of the street canyon. As building-roof temperature decreases, wind speed at the roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow, and updraft becomes stronger). Building-roof cooling contributes to the reduction of average concentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermal environment and air quality in urban areas.

도시 내 가로수의 광선투과량에 따른 온도저감 효과 - 서울시 서초구를 중심으로 - (Temperature Reduction Effect According to Light Transmittance of Urban Street Trees - Focused on Seocho-gu in Seoul -)

  • 김은범;김남춘;신지훈;송원경;김도희
    • 한국환경복원기술학회지
    • /
    • 제20권3호
    • /
    • pp.45-54
    • /
    • 2017
  • With rapid urbanization and reckless urban development in the 21st century, the urban environment has gradually gotten worse, and urban heat island effect has been dramatically intensified. Thus, the importance of street greenery that can mitigate the urban heat island effect has further been highlighted. In this regard, this study was aimed at selecting suitable plant species for street greenery to reduce the urban heat island effect. Towards this end, five roads located in Seocho-gu, Seoul were selected as study sites, and plant species composition and difference of surface temperature were compared and analyzed in relation to the light transmittance. The street with the greatest temperature difference is Bangbae-ro(Platanus occidentalis). On the other hand, the road with the lowest temperature difference is Nambusunhwan-doro(Metasequoia Glyptostroboides). The effect of temperature reduction was found to be associated with light transmittance.Bangbae-ro(Platanus occidentalis) with the lowest light transmittance showed the highest temperature difference and Nambusunhwan-doro(Metasequoia Glyptostroboides) with the highest light transmittance showed the lowest temperature difference. It is analyzed that there are most differences in temperature when the amount of lights coming in between the crown is small. The temperature reduction effect can be obtained by planting deciduous broad-leaved trees. Also species with dense crown and broad width of crown will be able to maximize the effect of temperature reduction. In future studies, it will be necessary to expand the other species of trees in the street, and analyze the germicidal trees and shrubs as well as the differences in the packaging materials.

대구광역시 중구의 가로수 및 열섬 모자이크 현황 분석 (Analysis of Street Trees and Heat Island Mosaic in Jung-gu, Daegu)

  • 김수봉;정응호;김기호
    • 한국환경과학회지
    • /
    • 제15권4호
    • /
    • pp.325-332
    • /
    • 2006
  • The purpose of this paper is to suggest practical suggestions to mitigate Urban Heat Island(UHI) problems in Daegu regarding urban surface temperature. Urban street trees's size and the relations between urban land use types and surface temperature are analysed using aerial photos, the numerical value map and Landsat TM image with special reference to Jung-gu. Total urban street tree's crown size is $156,217.6m^2$ and it is equal to 2.24% of study area. In addition, the size of 'city and residential area' is $6,681,870m^2$(95.7% of study area), which causes UHI and the total size of 'river' shows the lowest surface temperature area and 'road' and 'business and service area' are the highest surface temperature zones. Therefore, it is probable that the network between urban street trees and the lowest surface temperature areas mitigate UHI effects.

가변색온도 가로등 구현을 위한 혼색LED의 조명특성 (A Light Characteristics of Mixed-Color LED for the Variable Color Temperature Street Light)

  • 정병호;이강연;최연옥;김대곤;김남오;민완기
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.142-147
    • /
    • 2009
  • Conventional HP(high pressure) sodium or Metal-halide lamps have a life span of around one year requiring at least annual replacement and maintenance. High Power LED lights require no regular maintenance further increasing savings on replacement bulbs, access equipment and labour costs. New installations benefit from a substantial reduction in the cost of expensive heavy duty cable required for sodium lighting. Especially, LED light can achieve variable color temperature, high functional performance in the field of street light. There are two main method to achieve variable color temperature function of the street light. one method is using RGB multi-chip LED, the other is using Orange-White LED method. In this paper, it was compare RGB Multi-chip LED with white-orange LED for there characteristics performance.

LED 가로등의 발열 패턴 및 전류 특성에 관한 연구 (Study on Thermal Pattern and Current Characteristics of an LED Street Lamp)

  • 김향곤;최충석
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.357-361
    • /
    • 2009
  • This study performed analysis on the thermal pattern and current characteristics of an LED ((Light Emitting Diode) street lamp. It did this using a TVS (Thermal Video System) to analyze the LED street lamp's thermal pattern, and measured its characteristics using an oscilloscope. The ambient temperature and humidity during the experiment were maintained at $24{\pm}2[^{\circ}C]$ and 50~60[%]. The capacity of the LED street lamp was 120[W] and nine sets of modules were arranged at uniform intervals. On one module, 24 LED lamps were arranged in a radial pattern. The analysis of the thermal diffusion pattern at the front of the LED lamp showed that the maximum surface temperature was approximately $34[^{\circ}C]$. In addition, there was almost no change in the temperature of the upper cover, and the temperature at the side showed a uniform thermal diffusion pattern. The surface temperature of the converter converting AC to DC increased to approximately $46[^{\circ}C]$. The analysis results of the thermal characteristics of one LED indicated uniform thermal characteristics for an initial eight minutes. However, the temperature at the center of the LED increased to approximately $82[^{\circ}C]$ after 12 minutes had elapsed. It can be seen from this that the temperature at the center of the LED was higher than the allowable temperature, $70[^{\circ}C]$ of the insulating material for general electrical devices. Therefore, it is necessary to design a lamp in such a way that the plastic insulating material does not come into contact with or get close to the LED lamp. The voltage of the LED lamp converted by the AC/DC converter was measured at DC 27[V] and the current was DC 13[A]. Consequently, it can be seen that in order to secure an adequate light source, it is important to supply a stable current that was greater than the current of other light sources. Therefore, appropriate radiation of heat is required to secure the stability and reliability of the system.

Evaluation of Water Retentive Pavement as Mitigation Strategy for Urban Heat Island Using Computational Fluid Dynamics

  • Cortes, Aiza;Shimadera, Hikari;Matsuo, Tomohito;Kondo, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.179-189
    • /
    • 2016
  • Here we evaluated the effect of using water retentive pavement or WRP made from fly ash as material for main street in a real city block. We coupled computational fluid dynamics and pavement transport (CFD-PT) model to examine energy balance in the building canopies and ground surface. Two cases of 24 h unsteady analysis were simulated: case 1 where asphalt was used as the pavement material of all ground surfaces and case 2 where WRP was used as main street material. We aim to (1) predict diurnal variation in air temperature, wind speed, ground surface temperature and water content; and (2) compare ground surface energy fluxes. Using the coupled CFD-PT model it was proven that WRP as pavement material for main street can cause a decrease in ground surface temperature. The most significant decrease occurred at 1200 JST when solar radiation was most intense, surface temperature decreased by $13.8^{\circ}C$. This surface temperature decrease also led to cooling of air temperature at 1.5 m above street surface. During this time, air temperature in case 2 decreased by $0.28^{\circ}C$. As the radiation weakens from 1600 JST to 2000 JST, evaporative cooling had also been minimal. Shadow effect, higher albedo and lower thermal conductivity of WRP also contributed to surface temperature decrease. The cooling of ground surface eventually led to air temperature decrease. The degree of air temperature decrease was proportional to the surface temperature decrease. In terms of energy balance, WRP caused a maximum increase in latent heat flux by up to $255W/m^2$ and a decrease in sensible heat flux by up to $465W/m^2$.

A Study on the Thermal Analysis of Circular LED Street Lights

  • So, Byung Moon
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.99-105
    • /
    • 2017
  • This paper confirms the similarity of temperature tendency through numerical analysis and comparison with test, and it also confirms that temperature prediction of LED lightings is possible by numerical analysis. We confirmed that the temperature difference is about $10{\sim}20^{\circ}C$ except for some measurement points and shows similar tendency with the interpretation through manufacturing and performance analysis of AL heat sink applied Circular LED street lights and manufacturing and performance analysis of CMP-PLA heat sink applied Circular LED street lights. The simulations use Octree technique in SC/Tetra to set the grid size df the surface.

  • PDF

75W급 LED 가로등 모듈의 방열판 최적화와 열특성 분석 (Optimization of Heatsink and Analysis of Thermal Property in 75W LED Module for Street Lighting)

  • 이승민;이세일;양종경;이종찬;박대희
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.609-613
    • /
    • 2010
  • In this paper, we optimized and simulated the heatsink of 75W LED module for street lighting and evaluated the optical properties with the manufactured heatsink. the structure of LED package make simple as chip and heatslug and thermal flow is analyzed by using the FEM(Finite Element Method) with CFdesign V10. Also, we measured the temperature of heatsink and evaluated the optical properties with infrared thermal image camera and integrated sphere system for luminous flux in $1\;[m^3]$ box. As results, Heatsink optimized in 3 mm pin thickness, 6 mm base thickness and 16 number of pin count by using Heatsink-designer and got the results which is the temperature of $47.37\;[^{\circ}C]$ and thermal resistance of $0.48407\;[W/^{\circ}C]$. In thermal flow simulation, the temperature of heatsink decreased from $51.54\;[^{\circ}C]$ to $51.51\;[^{\circ}C]$ and the temperature of heatsink by the time in real measurement decreased from $47.03\;[^{\circ}C]$ to $46.87\;[^{\circ}C]$. Moreover, we improve 0.68 % in the decreased ratio of the luminous flux.

도시 가로수의 증산 작용으로 인한 불쾌지수 변화 분석 (Analyzing Change of Discomfort Index for Transpiration of Street Tree)

  • 윤석환;이동근;박채연
    • 한국환경복원기술학회지
    • /
    • 제23권5호
    • /
    • pp.29-43
    • /
    • 2020
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. The cooling effect of street tree is regarded as a effective way to ameliorate the urban heat environment. The effect is largely made up of shadow formation and transpiration. This study aims to identify how the transpiration affects the discomfort index by analyzing comprehensive impact of the transpiration on the air temperature and relative humidity. The changes in the amount of transpiration, air temperature, and relative humidity were estimated for Seogyo-dong area which has a lot of floating population in Seoul, at 2 p.m. in dry day in July and August. On average, the transpiration of the street tree decreased the temperature 0.3℃ and increased the relative humidity 2.6% in an hour. As a result of these changes in temperature and humidity, the discomfort index rose mostly(0.036 on average). It was always get rise especially on the day when the discomfort index was above 80(0.05 on average). However, compared with the significant change in temperature and humidity, the variation of the discomfort index itself was very slight(up to 0.107). Therefore, the effect of transpiration by the street trees might not be effective in the planning to improve the thermal environment(especially on the day when the discomfort index is high). It is necessary to select the species of trees and planting location considering the cooling effect of shade formation synthetically.

거리협곡 벽면녹화 조성유형에 따른 미기상 변화 및 열환경 평가 (A Study on Verifying the Effect of Thermal Environment Control of Street Canyons based on Application of Green Wall System)

  • 김정호;최원준;윤용한
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.311-322
    • /
    • 2016
  • This study reduced and built Street Canyons created by skyscrapers in order to verify effect of Street Canyons by green wall within the city centre and analysed influence factors on temperature reduction according to applicative types of green wall in the lab. Applicative types were divided into three types such as non- greening type(Case A), one-side greening type(Case B), both side greening type(Case C). The result of analysis of each types showed that average temperature of Case B and Case C is respectively $1.0^{\circ}C$ and $1.7^{\circ}C$ lower than Case A. The result of analysis of WBGT was that the highest temperature was given by Case A($40.2^{\circ}C$) and second one was from Case B($39.8^{\circ}C$) and third one was from ($39.1^{\circ}C$) and in UTCI Case A records the highest temperature of $34.7^{\circ}C$ and Case B provided the second highest temperature of $33.9^{\circ}C$ and Case B gave the lowest temperature of $32.7^{\circ}C$. In PMV the highest temperature of 2.65 was from Case B and second one of 2.61 was from Case A and third one of 2.54 was from Case C. Duncan analysis of each types based on solar radiation and thermal comfort generated that there was analytical significance between Case A and Case B and Case B in terms of each types of average temperature reduction. The significance of thermal comfort in WBGT, MRT, PMV showed non-significance but, In UTCI it was analysed that there was significance between Case C and Case A.