• Title/Summary/Keyword: Strain gauge test

Search Result 170, Processing Time 0.026 seconds

Preminary Study on Stress Analysis of Rock-mass Support Structure using Laboratory Test and Numerical Simulation (실내실험과 수치해석을 이용한 암반지보구조물의 응력거동 분석을 위한 기초 연구)

  • Lee, Jae-Ho;Moon, Hong-Deuk;Yoo, Ji-Hyeung;Kim, Hyuk;Son, Yeong-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.825-831
    • /
    • 2010
  • In this study is stress behavior of steel support structure is to identify basic research. Steel stress due to load step to determine the behavior of steel using strain gauge steel loading test was performed. Numerical analysis and steel loading test using strain gauge on the actual steel stress behavior was analyzed. First, when tensile loading 3.5tonf load side of the plastic behavior appeared. Elastic model, using numerical analysis and comparison of results, the actual value is saved and you can see some difference. This repeated loading tests on steel can be seen from the results of the stress behavior of the steel rather than the elastic behavior of elastic-plastic behavior is because you can see. In addition, the upper and lower steel stress in compression and tension behavior represents the behavior was similar, but different. Steel loading test results, Y-axis get a compression if X-axis is tension. The future based on this study, the stress sensitivity curve of magnetic anisotropy sensor for non-destructive stress measurement technique for the study will be performed. And the behavior of plastic zone and residual stress to determine the numerical analysis using non-elastic model is needed.

  • PDF

A Study on Non-linear Behavior in Welded Structures by Mechanical Stress Release Method (기계적 응력 완화법에 의한 용접구조물의 비선형 거동에 관한 연구)

  • 김정현;장경복;윤훈성;강성수;조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.66-71
    • /
    • 2003
  • The release of residual stress by mechanical loading and unloading is often performed in the fabrication of box structure fur steel bridge. The proper degree of loading and unloading is significant at release method of residual stress by mechanical loading because that degree is changed by material and geometric shape of welded structure. Therefore, the simulation model that could exactly analyze the release of residual stress by mechanical loading is to be necessary. In this study, the non-linear behavior of weldments under external loading and unloading, such as the decrease and increase of structure stiffness, was investigated by monitoring of nominal stress and strain. Tensile loading and unloading test and the proper degree of stress relaxation was measured by sectioning technique using strain gauge. Analysis model that is indispensable for the effective application of MSR method was established on the basis of test and measurement result.

Analysis on the Interface Edge Crack in Aluminum Bonded Single Lap-joint (알루미늄 단순겹치기 접착이음의 에지계면균열에 대한 연구)

  • Yu, Y.C.;Park, J.H.;Jeong, E.S.;Yi, W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.655-659
    • /
    • 1997
  • The analysis of cracks at the interface between dissimilar materilar has received a great deal of attention in recent years. In this paper we conducted the static tensile test for the aluminum bonded single lap-joint with the interface edge crack. Comparing this results, that is ultimate load and strain value of aluminum adherend by strain gauge with the fracture mechanics parameters, compliance and stress intensity factors acquied from the boundary element analysis, we concluded that there are critical value of crack length to provoke the interface fracture.

  • PDF

A Study on the Durability Design of an Automotive Seat Frame (자동차 시트 프레임 구조의 내구성 향상 설계에 관한 연구)

  • 우창수;조현직;구정서;권재도
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.50-57
    • /
    • 2004
  • Structural analysis and fatigue tests have been performed to develop design and evaluation technologies of automotive seat frames. Under the back moment loading condition, the numerical simulation unveiled the maximum stress up to the yield strength at the side frame bracket. To measure the stresses under the test condition, strain gauges were attached to some weakest points of the side frames. the measured strains are in good agreements with the CAE results. On the other hand, some fatigue tests have been performed using the side frame bracket specimens made of various welding types to evaluate their durabilities. From the fatigue tests and the numerical analyses, it was recommended that the bracket welding position should be moved upward.

Performance Monitoring and Load Analysis of Wind Turbine (풍력발전기의 성능 모니터링 및 하중분석)

  • Bae, Jae-Sung;Kim, Sung-One;Youn, Joung-Eun;Kyung, Nam-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.385-389
    • /
    • 2004
  • Test facilities for the wind turbine performance monitoring and mechanical load measurements are installed in Vestas 100 kW wind turbine in Wollyong test site, Jeju island. The monitoring system consists of Garrad-Hassan T-MON system, telemetry system for blade load measurement, various sensors such as anemometer, wind vane, strain gauge, power meter, and etc. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the established monitoring system, the wind turbine is remotely monitored. From the measured load data, the load analysis has been performed to obtain the load power spectral density and the fatigue load spectra of the wind turbine.

  • PDF

Experimental investigation on shear capacity of RC beams with GFRP rebar & stirrups

  • Vora, Tarak P.;Shah, Bharat J.
    • Steel and Composite Structures
    • /
    • v.21 no.6
    • /
    • pp.1265-1285
    • /
    • 2016
  • This paper presents experimental results of advanced investigation carried out on the beams reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar and stirrups. Twelve beams reinforced with GFRP and one beam with steel reinforcement of size $230{\times}300{\times}2000mm$ were investigated. Longitudinal reinforcement, shear span and spacing of stirrups were the main variables to form the set. In advanced testing three types of strain gauges for steel, composite and concrete surface were applied to observe strain/stress development against the applied load. Live data were recorded from four strain gauges applied on stirrups, one at center on longitudinal reinforcement, two on the concrete surface and central deflection during the test. Although the focus of the paper was mainly on the behavior of GFRP shear reinforcement, other parallel data were observed for the completeness of the test. Design recommendations of ISIS Canada Design Manual (2007), Japan Society of Civil Engineers (1997) and American Concrete Institute (ACI-440.1R-06) were reviewed. Shear design predictions were compared with experimental results in which it was observed that all the three standards provided conservative predictions. However, ACI found most efficient compare to other two there is room to improve the efficiency of the recommendations.

Evaluation of the Effect of Coupler on the Ductility of Rebar by Uniaxial Tensile Test (1축 인장시험을 통한 커플러가 철근 연성도에 미치는 영향 평가)

  • Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan;Jung, Chi-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.90-98
    • /
    • 2018
  • Recently, various reinforced concrete joints have been used in reinforced concrete structures. Therefore, it is important to grasp the tensile properties of the spliced rebar. In this study, uniaxial tensile tests were conducted on Grade 60 D22(#7), D29(#9), and two kinds of couplers manufactured according to ASTM A615 standard for evaluating ductility of coupler joints. The strain was measured using an image processing method more accurate and capable of measuring at various points freely. As the result of uniaxial tensile test, it was possible to calculate the stress-strain relationship and the longitudinal strain distribution according to the stress stages and it was founded that the average strain becomes lower as more occupying the coupler joint portions in the same gauge length. In addition, the empirical equations are proposed to account for the effect of the length of the coupler on the ultimate strain and the rupture strain.

Comparison of Elastic Moduli of Subgrade Soils Using Plate Loading Test, Soil Stiffness Gauge and Dynamic Cone Penetrometer (평판재하시험, 흙강성측정기 및 동적콘관입시험기를 이용한 노상토의 탄성계수 비교)

  • Kim, Kyu-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2015
  • This paper describes the correlation and relationship between elastic moduli measured by three stiffness measurement methods with different mechanical characteristics to evaluate the compaction characteristics of subgrade soils. The Soil Stiffness Gauge (SSG) with very small strain (${\approx}0.001%$) ranges, static Plate Loading Test (PLT) with mid-level strain (${\approx}0.01{\sim}0.1%$) ranges, and Dynamic Cone Penetrometer (DCP) using penetration resistance were implemented to measure the elastic modulus. To use the elastic modulus measured by different measurement methods with a wide range of strain in practice, it is required to identify the correlation and relationship of measured values in advance. The comparison results of the measured elastic moduli ($E_{SSG}$, $E_{PLT}$, $E_{DCP}$) using the three measurement methods for domestic and overseas subgrade soils under various conditions indicate that the evaluated elastic modulus relies on the types of soils and the level of stress condition. The correlation analysis of the measured elastic moduli except the data of cement treated soils indicates that the static elastic modulus ($E_{PLT}$) is evaluated as about 60 to 80% of the dynamic elastic modulus ($E_{SSG}$). Unusual soils such as cement treated soils are required to be corrected by the stress correction during the correlation analysis with typical soils, because these types of soils are sensitive to the stress condition when measuring the static elastic modulus ($E_{PLT}$) of soils. In addition, when considering the use of DCP data for the evaluation of the elastic modulus ($E_{DCP}$), the measured data of the elastic modulus less than 200 MPa show more reliable correlation.

Implementation of Sensor-embedded Main Wing Model for Structural Health Monitoring of the Ultra Light Airplane (초경량항공기의 구조적 안전진단을 위한 센서 매립형 주익 모델 제작)

  • Song, Jae-Hoon;Yang, Jae-Won;Rim, Mi-Sun;Kim, Yoon-Young;Park, Hoon;Seok, Jong-Nak;Kim, Chun-Gon;Choi, Sun-Woo;Lee, Jang-Yeon
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.178-184
    • /
    • 2012
  • In this study, implementation process of sensor-embedded main wing model for structural health monitoring is described. Fiber Bragg Grating (FBG) Sensor, Plumbum-Zirconate-Titanate (PZT) Sensor, and strain gauge are installed in the main wing of Jabiru UL airplane as a test-bed of Health and Usage Monitoring System (HUMS).

Hydraulic Test for Strength Evaluation of Valve (수압시험을 이용한 밸브의 강도평가)

  • Yi, Sodam;Ko, Junbok;Park, Yongsoo;Kim, Seongsu;Baek, Kibong;Suh, Suhkhoon;Ha, Dongsung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.395-400
    • /
    • 2017
  • Hydraulic test was conducted to evaluate the structural strength of valve exposed to high pressure environment during combustion progress. For the proof pressure, 1.05 times higher pressure than MEOP was applied in the hydraulic test. Two units of valves were used in the hydraulic test. The result for measured strain of the valve dependent on the pressurization conditions during the test were verified comparing with the results for the finite element analysis. Observing the difference between the results for the finite element analysis and the hydraulic test, the difference was within 20% error and the plastic deformation was not generated.

  • PDF