• Title/Summary/Keyword: Strain gauge test

Search Result 170, Processing Time 0.035 seconds

Development of an Objective Softness Evaluation Method and Its Standardization for Hygiene Paper (위생용지 부드러움의 객관적 평가 방법 개발 및 표준화)

  • Ko, Young Chan;Park, Jong-Moon;Moon, Byoung-Geun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.80-84
    • /
    • 2015
  • Softness is considered one of the most important attributes of hygiene paper such as tissue and towel. Being subjective in nature, however, softness attribute has been generally believed to be impossible to evaluate using objective methods. Hallmark in his pioneering work proposed that tissue subjective softness should be mainly consisted of the bulk softness component and surface softness component. The bulk softness component can be determined by tensile stiffness; the surface softness component by surface tester. The surface friction turns out far more important than the surface roughness in determining the surface softness component. It cannot be too much emphasized that both results of the tensile stiffness and the surface friction should depend on measuring conditions such as an instrument used, sample sizes (e.g., basis weight, length, and width) and operating conditions of the instrument (e.g., gauge length, cross-head speed, size of stylus, and its scanning speed). This indicates that a direct comparison of the test results would be impossible or misleading unless they have been tested under the identical conditions. This may explain why the standard objective test method for tissue softness has not been available at present.

Relationship between maximum bite force and facial skeletal pattern (최대 교합력과 안면 골격 형태에 관한 연구)

  • Choi, Won-Cheul;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.437-451
    • /
    • 2003
  • The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

Pull-out Test of Steel Pipe Pile Reinforced with Hollow Steel Plate Shear Connectors (유공강판 전단연결재로 보강된 강관말뚝 머리의 인발실험)

  • Lee, Kyoung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.285-291
    • /
    • 2016
  • The purpose of this study was to evaluate the structural capacity of steel pipe pile specimens reinforced with hollow steel plate shear connectors by pull-out test. Compressive strength testing of concrete was conducted and yield forces, tensile strengths and elongation ratios of re-bars and hollow steel plate were investigated. A 2,000kN capacity UTM was used for the pull-out test with 0.01mm/sec velocity by displacement control method. Strain gauges were installed at the center of re-bars and hollow steel plates and LVDTs were also installed to measure the relative displacement between the loading plate and in-filled concrete pile specimens. The yield forces of the steel pipe pile specimens reinforced with hollow steel plate shear connectors were increased 1.44-fold and 1.53-fold compared to that of a control specimen, respectively. Limited state forces of steel pipe pile specimens reinforced with hollow steel plate shear connectors were increased 1.23-fold and 1.29-fold compared to that of a control specimen, respectively. Yield state displacement and limited state displacement of steel pipe pile specimens reinforced with hollow steel plate shear connector were decreased 0.61-fold and 0.42-fold compared to that of a control specimen, respectively.

Monitoring-Evaluation System for Lifting Heavy Structures using 3D Location Data (3차원 위치좌표를 이용한 대형 구조물 양중을 위한 계측 - 평가 시스템)

  • Lee, Myung Ho;Chun, Sung Chul;Oh, Bohwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.413-420
    • /
    • 2009
  • Heavy structures such as large roof structures and superbeams were lifted using hydraulic jacks. Moreover, member verticality and horizontality checks were performed at every construction stage to monitor the measuring tapes for their structural safety, using CCTV. When the relative displacement exceeded the predetermined limit, the hydraulic systems were terminated. After adjusting the relative displacement manually, lifting was resumed. The accuracy of the relative displacement was found not to be reliable, however, due to eye check using CCTV, and it took a long time due to manual adjustment. Moreover, real-time monitoring was impossible. To address these problems, the monitoring-evaluation system for the stable lifting of heavy structures was proposed, using the total station of the automatic-target-recognition type, laser-distance-measuring devices, a data logger, a strain gauge, and others. After developing a program for the operation of the system and for the acquisition of data, a mock-up test was conducted in a large-scale structural laboratory to evaluate the accuracy and applicability of the system. The stable acquisition and applicability of data was confirmed in the test.

A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis (임플란트와 상부보철물의 임상적/실험적 부적합 평가에 관한 문헌고찰)

  • Kim, Jong-Hoi;Cho, Woong-Rae;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.56 no.9
    • /
    • pp.462-478
    • /
    • 2018
  • The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.

  • PDF

A Experimental Study of Aerodynamic Interference on Quad-Tilt Propeller UAV Wings in Forward Flight Condition (전진 비행하는 Quad-Tilt Propeller 형상 무인기 날개에서 나타나는 공력간섭 현상에 대한 실험적 연구)

  • Kim, Taewoo;Chung, Jindeog;Kim, Yangwon;Park, Cheolwan;Cho, Taehwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.2
    • /
    • pp.81-89
    • /
    • 2019
  • In this study, wind tunnel test on Quad-Tilt Propeller which has tandem wings is carried out to analyze the aerodynamic interference effect of front wing and propeller on rear wing during forward flight. Using 6-axis balance system, forces and moments of whole aircraft were measured and using strain gauge at wing root, bending moments were measured to observe change of aerodynamic force of each wings. A 12-hole probe was used to measure the flow field in the wing and propeller wake. Flow characteristics were observed qualitatively through flow visualization experiment using tuft and smoke. To measure the aerodynamic interference by elements, the influence of front wing and propeller on rear wing was analyzed by changing the wings and propellers mount combination.

Effect of Fabric Sensor Type and Measurement Location on Respiratory Detection Performance (직물센서의 종류와 측정 위치가 호흡 신호 검출 성능에 미치는 효과)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Jeong-Hwan;Kwak, Hwi-Kuen;Ko, Yun-Su;Chae, Je-Wook;Oh, Su-Hyeon;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.22 no.4
    • /
    • pp.97-106
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the type and measurement location of a fabric strain gauge sensor on the detection performance for respiratory signals. We implemented two types of sensors to measure the respiratory signal and attached them to a band to detect the respiratory signal. Eight healthy males in their 20s were the subject of this study. They were asked to wear two respiratory bands in turns. While the subjects were measured for 30 seconds standing comfortably, the respiratory was given at 15 breaths per minute were synchronized, and then a 10-second break; subsequently, the entire measurement was repeated. Measurement locations were at the chest and abdomen. In addition, to verify the performance of respiratory measurement in the movement state, the subjects were asked to walk in place at a speed of 80 strides per minute(SPM), and the respiratory was measured using the same method mentioned earlier. Meanwhile, to acquire a reference signal, the SS5LB of BIOPAC Systems, Inc., was worn by the subjects simultaneously with the experimental sensor. The Kruskal-Wallis test and Bonferroni post hoc tests were performed using SPSS 24.0 to verify the difference in measurement performances among the group of eight combinations of sensor types, measurement locations, and movement states. In addition, the Wilcoxon test was conducted to examine whether there are differences according to sensor type, measurement location, and movement state. The results showed that the respiratory signal detection performance was the best when the respiratory was measured in the chest using the CNT-coated fabric sensor regardless of the movement state. Based on the results of this study, we will develop a chest belt-type wearable platform that can monitor the various vital signal in real time without disturbing the movements in an outdoor environment or in daily activities.

Analysis of the crack propagation rules and regional damage characteristics of rock specimens

  • Li, Yangyang;Xu, Yadong;Zhang, Shichuan;Fan, Jing;Du, Guobin;Su, Lu;Fu, Guangsheng
    • Geomechanics and Engineering
    • /
    • v.24 no.3
    • /
    • pp.215-226
    • /
    • 2021
  • To study the evolution mechanism of cracks in rocks with multiple defects, rock-like samples with multiple defects, such as strip-shaped through-going cracks and cavity groups, are used, and the crack propagation law and changes in AE (acoustic emission) and strain of cavity groups under different inclination angles are studied. According to the test results, an increase in the cavity group inclination angle can facilitate the initial damage degree of the rock and weaken the crack initiation stress; the initial crack initiation direction is approximately 90°, and the extension angle is approximately 75~90° from the strip-shaped through-going cracks; thus, the relationship between crack development and cavity group initiation strengthens. The specific performance is as follows: when the initiation angle is 30°, the cracks between the cavities in the cavity group develop relatively independently along the parallel direction of the external load; when the angle is 75°, the cracks between the cavities in the cavity group can interpenetrate, and slip can occur along the inclination of the cavity group under the action of the shear mechanism rupture. With the increase in the inclination angle of the cavity group, the AE energy fluctuation frequency at the peak stress increases, and the stress drop is obvious. The larger the cavity group inclination angle is, the more obvious the energy accumulation and the more severe the rock damage; when the cavity group angle is 30° or 75°, the peak strain of the local area below the strip-shaped through-going fracture plane is approximately three times that when the cavity group angle is 45° and 60°, indicating that cracks are easily generated in the local area monitored by the strain gauge at this angle, and the further development of the cracks weakens the strength of the rock, thereby increasing the probability of major engineering quality damage. The research results will have important reference value for hazard prevention in underground engineering projects through rock with natural and artificial defects, including tunnels and air-raid shelters.

Evaluation of polymerization shrinkage stress in silorane-based composites (Silorane계 복합레진의 중합수축응력의 평가)

  • Ryu, Seung-Ji;Cheon, Ji-Hoon;Min, Jeong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.188-195
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate the polymerization shrinkage stress among conventional methacrylate-based composite resins and a silorane-based composite resin. Materials and Methods: The strain gauge method was used for the determination of polymerization shrinkage strain. Specimens were divided by 3 groups according to various composite materials. Filtek Z-250 (3M ESPE) and Filtek P-60 (3M ESPE) were used as a conventional methacrylate-based composites and Filtek P-90 (3M ESPE) was used as a silorane-based composites. Measurements were recorded at each 1 second for the total of 800 seconds including the periods of light application. The results of polymerization shrinkage stress were statistically analyzed using One way ANOVA and Tukey test (p = 0.05). Results: The polymerization shrinkage stress of a silorane-based composite resin was lower than those of conventional methacrylate-based composite resins (p < 0.05). The shrinkage stress between methacrylate-based composite resin groups did not show significant difference (p > 0.05). Conclusions: Within the limitation of this study, silorane-based composites showed lower polymerization shrinkage stress than methacrylate-based composites. We need to investigate more into polymerization shrinkage stress with regard to elastic modulus of silorane-based composites for the precise result.