• 제목/요약/키워드: Strain Guage

검색결과 10건 처리시간 0.027초

변형률 모드시험방법의 특성 및 응용 (A Study on the Characteristics and Applications of a Strain Modal Testing Method)

  • 차주환;하태희;이건명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.216-221
    • /
    • 1997
  • A strain modal testing method has been applied to a cantilever beam to investigate the characteristics of the method. By applying the method to an analytical and an experimental system, it was shown that accurate modal parameters can be estimated from the FRFs using a current modal parameter extraction algorithm. The modal parameters estimated by the method are more accurate than those by the conventional method which uses accelerometers when the tested system is of light weight. The strain response for a given excitation force and the force which causes the response can be predicted using the measured strain FRFS.

  • PDF

Zigbee 무선통신 네트워크 기반 변형측정 시스템 설계 및 개발 (Design and Development of Strain Measurement System Based on Zigbee Wireless Network)

  • 김상석;박장식;고석조;노희종
    • 한국전자통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.585-590
    • /
    • 2012
  • 본 논문에서는 구조물의 안전한 관리를 위하여 진동현방식 센서를 이용하여 변형을 측정하고 Zigbee 무선 네트워크를 통하여 원격 모니터링할 수 있는 시스템을 구현하였다. 구현한 변형측정기는 진동현방식 센서를 구동하여 출력되는 신호의 주파수를 측정하여 변형을 계산하고, 변형 측정에 있어 요구되는 온도 보상을 위한 온도를 측정한다. 2축 가속도센서를 이용하여 변형의 방향을 측정할 수 있다. 개발한 변형측정기에는 보다 효율적인 모니터링을 위하여 유무선 통신 기능이 있다. 실험을 통하여 개발한 진동현방식 변형측정 시스템이 원격모니터링에 효과적임을 확인한다.

평편족의 치료로 이용한 관절고정술시 스프링인대군 (spring ligament complex)에서 strain의 변화 (The strain of the spring ligament complex at different arthrodesis of the hindfoot for treatment of the flatfoot)

  • 이경태;배준우
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.38-42
    • /
    • 1997
  • It was well known that arthrodesis of the tarsal joint is an exellent procedure to correct the flatfoot deformity for relieving pain. Recently, concept of the selective tarsal joint fusion instead of the triple fusion was developedto preserve the joint motion. To investigate and compare the effect of the each different tarsal fusion, we measured the strain at the spring ligament, medial roof of the medial longitudianl arch. Five fresh frozen cadevar foot specimens, with distal half of the tibia were utilized. The superomedial portion of the spring ligament complex was dissected from the origin to the insertion. For each specimen, a calibrated open liquid metal strain guage was secured along the length of the superomedial portion. Under the specially devised test rig, measurement of the strain was taken at each test condition from the tare weight 18.2 lb followed by 38.2 lb., 82.2 lb and a maximum loads of 134.6 lb. : 1) unfused condition, 2) isolated subtalar fusion 3) isolated talonavicular fusion 4) combined subtalar and talonavicular fusion 5) triple fusion. Statistics showed that siginificant reduction in strain following the triple fusion, and from the subtalar fusion to triple fusion.

  • PDF

공선조건에 의한 구조물의 기하학적 변형해석에 관한 연구 (A Study on the Geometric Deformation Measurement of Structures by Collinearity Condition)

  • 강준묵;오원진;이진덕;한승희
    • 한국측량학회지
    • /
    • 제4권2호
    • /
    • pp.77-87
    • /
    • 1986
  • 구조물의 변형측정에 있어서 Strain gauge, Inclinometer, Dial gauge등을 이용한 방법과 측지학적인 방법들은 기구설치의 어려움과 경제적인 면은 물론 정확도면에서도 많은 문제점을 안고있다. 이에 최근 다방면으로 활용이 증대되고 있는 C. R. P(Close-Range Photogrammetry) 기법을 토목구조물의 변형측정에 적용하여 이를 공선조건으로 해석하였다. 피사체로 현수교모형을 제작하였으며 재하변형측정 실험을 실여, Dial gauge, Precision level, 정밀삼각측양을 통한 측정값과 비교하여 그의 타당성을 제시하였다. 또한 실구조물에 적용시 발생하는 제반문제점들을 고려하기위해 Camera 회전인자 $\omega$,$\psi$ 노출점높이 Z$_{L}$, 기선경사각 $\theta$의 변화를 다양하게 실험하여 그의 특성을 고찰하였다. 실험결과 Dial gauge, 정밀 Level, 정밀 삼각측양으로 측정한 변형양과 C. R. P로 측정한 변형양은 10$\mu\textrm{m}$ 이내의 증차로 상호접근하였으며 X와Z 좌표에 대한 표준오차는 수렴각 약 60$^{\circ}$에서 Y좌표는 수렴각 약 90$^{\circ}$에서 가장 작았으며 Z$_{L}$의 변화는 오차에 별다른 영향을 주지않는다. 또한 $\theta$가 증가함에따라 본 실험조건하에서는 Normal Case에서 30$^{\circ}$까지 Convergent Case에서는 15$^{\circ}$까지 양호한 정도를 보였으며 $\psi$$\omega$가 동시에 증가할수록 정도가 급격히 저하되며 특히 Y좌표의 정도에 많은 영향을 미침을 알 수 있었다. 이들 결과로 볼때 C. R. P해석기법은 정도와 경제적인 면에서 각종 구조물의 변형측정에 그 효용이 기대된다.대된다.

  • PDF

적층충전법이 복합레진의 중합수축에 미치는 영향 (EFFECT OF INCREMENTAL FILLING TECHNIQUE ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 김효석;이난영;이상호;오유향
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.481-490
    • /
    • 2005
  • 본 연구는 복합레진 중합 시 발생되는 중합수축이 C-factor에 의해 어떻게 영향 받는지 그리고 적층충전이 중합수축에 어떻게 영향을 미치는지 알아보고자 시행되었다. 세 가지 다른 깊이의 시편을 비교하였으며, 충전방법에 따른 비교를 위해 5가지 다른 충전방법에 따른 수축응력을 스트레인 게이지(Strain guage)를 사용하여 측정하였다. 이상의 실험을 통해 얻은 결과는 다음과 같다. 1. 와동깊이에 따른 수축응력을 측정한 결과 2mm와 3mm 시편에서는 800초 후 수축응력이 $2.18{\pm}0.23MPa$$2.38{\pm}0.07MPa$로 유의한 차이가 없었다(P>0.05). 2. 4mm 시편에서 800초 후 수축응력은 $1.99{\pm}0.24MPa$로 가장 낮은 수축응력을 보였다 (P<0.05). 3. 중합정도를 확인하기 위한 미세경도 실험결과 2mm와 3mm 시편에서는 상면과 하면의 미세경도 차이가 20% 내외로 양호한 중합상태를 보여주었으나, 4mm 시편에서는 상면과 하면의 미세경도가 현저한 차이를 보여 불완전한 중합이 이루어졌음을 알 수 있었다(P<0.05). 4. 충전방식에 따른 수축력의 차이를 비교한 결과 flowable resin을 이장하고 bulk로 충전한 제 5군에서 가장 낮은 수축응력을 보였으며, 제 1군(bulk충전)과 4군(oblique 적층충전)이 유사한 정도의 수축응력을 보였고, horizontal과 vertical하게 적층충전한 제 2군과 3군에서 가장 큰 수축응력이 관찰되었다(P<0.05).

  • PDF

악관절 기능장애환자의 교합력에 관한 연구 (A Study of Bite Force of the Patients with TMJ Dysfunction)

  • 이민규;이승우
    • Journal of Oral Medicine and Pain
    • /
    • 제9권1호
    • /
    • pp.139-145
    • /
    • 1984
  • A Kinematical study of bite force during voluntary isometric contraction was investigated in 20 Korean women with TMJ dysfunction and 50 Korean women a normal subject, ranging from 19 to 29 years old. The author observed maximal bite force, slope of bite force graph, curve index and duration of maximal bite force by way of the foil strain guage(MPM-3000) and Dymograph(Beckman). The obtained results were as follows : 1. Maximal bite forces were 26.48kg and 21.38kg for left and right side of normal subject and 12.85kg and 20.70kg for affected and mon-affected side of TMJ dysfunction patients. 2. The slope of bite force graph were 64.69。and 63.83。 for left and right side of normal subject and 53.14。and 69.57。for affected and non-affected side. 3. The curve indexes were 0.54 and 0.80 for left and right side of normal subject and 2.30 and 0.60 for affected and non-affected side. 4. The duration of maximal bite force were 383.12 msec and 393.60 msec for left and right side of normal subject and 345.30 msec and 312.25 msec for affected and non-affected side.

  • PDF

ENVIROMENTAL CONDITION DURING AIR SHIPMENT OF HORTICULTURAL PRODUCTS FROM OKINAWA TO TOKYO

  • Akinaga, Takayoshi;Kohda, Yoshihiro
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.413-422
    • /
    • 1993
  • Air shipment affords the quickest possible delivery of horticultural products. The price of air shipped horticultural products are relatively high as most of these products are perishable. Usually the temperature in the cargo compartment is not controlled during flight. Thus, special attention should be paid to procooling prior to shipment. The environmental condition during transportation of horticultural products is an essential parameter for maintaining the quality of perishable products. Commonly horticultural products were loaded by ULD(Unit Load Devices) as a container or pallet in the aircraft (except for small aircraft) . Therefore, inside temperature of the container and cargo compartment came into question. Scarce literature on the relationship between environmental condition and quality changes of horticultural products during air shipment can be found. By the stand point of keeping fresh quality, investigations on the actual condition of air shipments were carried out to improve the technique during the distribution process of fresh horticultural products. Temperature, humidity, atmospheric pressure, carbon dioxide, ethylene, impacts, and changes in quality during the air shipment of snapbeans, okras and chrysanthemums were measured. Temperature was measured by recording thermometers, relative humidity by recording hygrometers, atmospheric pressure by a strain -guage type pressure sensor, carbon dioxide by testing tubes, ethylene by sampling bags and a gaschromatograph, impacts and vibrations by impact recorders and a 3D accelerometer. Relationships between environmental conditions and quality changes during air shipments were clarified. It was expected from investigations into actual shipments that the ventilation and insulation properties of air freight containers were related to the quality of agricultural products. Aircraft can no directly load and unload trucks into them. The transshipment is inclined to cause shocks and vibrations, and to invite damages within a short time.

  • PDF

LED 광중합기의 조사 mode가 복합레진의 미세경도 및 수축응력에 미치는 영향 (INFLUENCE OF IRRADIATION MODES ON THE MICROHARDNESS AND THE POLYMERIZATION CONTRACTION OF COMPOSITE RESIN POLYMERIZED WITH LED CURING UNIT)

  • 박인호;오유향;이난영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제32권2호
    • /
    • pp.312-320
    • /
    • 2005
  • 이 연구의 목적은 LED 광중합기(Elipar Freelight $2^{(R)}$, 3M-ESPE, USA)의 조사 mode에 따른 복합레진($Supreme^{(R)}$, Filtek $Flow^{(R)}$, 3M-ESPE, USA)의 수축응력과 미세경도를 평가하는 것이다. 수축응력을 측정하기 위해 스트레인 게이지가 사용되었다. 표본은 조사 mode와 충전방법에 따라 6개의 군으로 나누어졌다. A군 : Filtek $Flow^{(R)}$ 이장, $Supreme^{(R)}$ 충전, 10초 광중합, B군 : Filtek $Flow^{(R)}$ 이장 $Supreme^{(R)}$ 충전, 15초 광중합, C군 : Filtek $Flow^{(R)}$ 이장, $Supreme^{(R)}$ 충전, 15초 soft start 광중합, D군 : $Supreme^{(R)}$ 충전, 10초 광중합, E군 : $Supreme^{(R)}$ 충전, 15초 광중합, F군 : $Supreme^{(R)}$ 충전, 15초 soft start광중합. 스트레인 게이지를 아크릴릭 링에 부착하고 strainmeter에 연결한 후 광중합하고 10분 동안 1초 간격으로 측정하고 기록하였다. 24시간 후에 각각 표본의 미세경도를 측정하였다. 결과는 ANOVA와 Tukey test를 이용해 통계학적으로 분석하였다. 결과는 다음과 같았다. 1. Soft start curing 했을 때 수축응력이 낮았다(p<0.05). Flowable resin을 이장한 군에서는 효과가 없었다. 2. 10초간 조사한 군은 15초간 조사한 군에 비해 수축응력이 적었다(p<0.05). 3. 미세경도 측정결과 상면과 하면에서 각 군 간에 차이는 없었다(p>0.05). 하지만, 하면의 미세경도가 상면에 비해 80%에 이르지 못했다.

  • PDF

스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교 (COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE)

  • 김영광;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제31권3호
    • /
    • pp.516-526
    • /
    • 2004
  • 심미적인 재료로 널리 사용되고 있는 복합레진은 중합과정에서 발생하는 수축으로 인해 여러 임상적 문제를 유발할 수 있다. 중합수축을 최소화하기 위한 방법의 하나로 복합레진의 성분을 변화시키는 방법이 연구되어 왔다. 본 연구의 목적은 기질조성의 변화를 통한 중합수축의 감소를 위해 최근 개발된 복합레진과 나노필러를 이용한 복합레진을 대상으로 중합과정에서 발생하는 수축량 및 수축응력을 측정하고 각 재료의 압축강도와 미세경도를 측정한 다음 그 결과들을 기존의 복합레진과 종합적으로 비교하여 평가해 보고자 하는 것이었다. 시편은 각 군당 20개씩 준비하였으며 실험에 사용된 복합레진으로는 Bis-GMA 기질에 TEGDMA와 UDMA를 혼합한 $Denfil^{TM}$(Vericom, 한국) $0.4-0.7{\mu}m$의 필러를 기준으로 나노필러를 첨가한 $Charmfil^{(R)}$(Dentkist, 한국), 기질의 TEGDMA의 상당부분을 UDMA와 Bis-EMA(6)로 대체한 $Filtek^{TM}$ Z250(3M-ESPE, USA), 그리고 나노필러만을 이용한 $Filtek^{TM}$ Supreme(3M-ESPE, USA)를 선정하였으며, 광중합기인 Curing Light 2500(3M, USA)를 이용하여 각각 40초간 광조사하였다. 광조사 후 1초 간격으로 10분간 수축응력과 선 수축률을 스트레인 게이지를 이용하여 측정한 다음 그래프로 분석하였고, 중합 1분 후와 10분 후의 수축응력과 선 수축률을 통계분석하였다. 또한 만능시험기와 미세경도기를 이용하여 중합 24시간 후 각 군의 압축강도와 미세경도를 측정하여 통계분석하였다. 수축응력 양상을 관찰해 본 결과 각 군에서 모두 중합 초기에 일시적인 재료의 팽창을 나타내었고, 그 후 수축응력이 약 1분간 급격히 증가한 다음 서서히 증가속도가 감소하는 양상을 보였다. 1분 후에서는 각 군간에 통계학적 유의성은 없었다. 10분 후에서는 IV군과 II군간에 유의한 차이가 존재하였다(p<.05). 1분간 측정한 회귀분석에서는 III군의 기울기가 가장 적었고, II군 I군, IV군의 순이었다. 중합수축률 측정 실험에서는 중합 초기의 일시적 인 팽창과 약 1분간의 급격한 수축 증가를 나타내었고 그 후 서서히 증가속도가 감소하는 양상을 보였다. 1분 후에서는 IV군과 III군간에 유의한 차이가 있었다(p<.05). 10분후에서는 IV군이 I군과 III군에서 유의 한 차이가 있었으며 II군과 III군간에도 유의한 차이가 있었다(p<.05). 1분간 측정한 회귀분석에서는 II군의 기울기가 가장 적었으며, IV군, III군, I군의 순이었다. 압축강도 실험에서는 III군, II군, IV군, I군의 순으로 높게 나타났으며, III군이 IV군과 I군에 유의한 차이가 있었다(p<.05). 미세경도 실험에서는 모든 군에서 상면에 비해 하면의 미세경도가 통계학적으로 유의차 있게 낮은 것으로 나타났다(p<.05). 이상의 결과를 종합하여 볼 때, hybrid 필러를 이용한 레진에서 상대적으로 낮은 수축률과 우수한 물성을 보였으며, 나노필러를 사용한 복합레진의 경우, 기존의 hybrid 필러를 이용한 레진에 비하여 수축응력을 감소시키지는 못하였다. 나노필러를 이용한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.

  • PDF

LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향 (EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT)

  • 정양석;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.623-631
    • /
    • 2007
  • 본 연구는 LED와 플라즈마 광원의 복합레진의 중합시 완속기시 중합방식(soft-start curing)이 수축응력에 미치는 효과를 비교, 평가하고자 하였다. 할로겐 광원으로 40초간 조사하여 복합레진을 중합한 경우와 LED와 플라즈마 광원의 단일광도 중합방식과 완속기시 중합방식으로 할로겐 40초 동안의 광에너지와 총량이 동일하도록 조사시간을 설정하였고 수축응력은 스트레인 게이지(Strain gauge)를 사용하여 측정하였다. 발생되는 수축응력을 비교, 분석 및 평가한 결과 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합 후 200초까지 수축응력이 급격하게 증가하였으나 이후 마지막 측정시간인 800초까지 완만한 증가를 보였다(P<0.05). 2. LED와 플라즈마 광원의 완속기시 중합방법이 단일광도 중합방법에 비해 수축응력이 낮게 나타났다(P<0.05). 3. 할로겐 광원과 LED와 플라즈마 광원의 완속기시 중합의 수축응력 비교에는 유의차가 없었다(P>0.05). 완속기시 중합 방식을 사용할 경우 단일광도 중합 방식보다 수축응력을 감소시킬 수 있어 임상적으로 고광도 광원인 LED와 플라즈마 광원의 경우 완속기시 중합 방식의 사용이 유리하다고 보여진다. 그러나 완속기시 중합시 불충분한 중합을 방지하기 위해서는 완속기시를 보완하는 추가적인 중합시간이 요구될 것으로 사료된다.

  • PDF