• Title/Summary/Keyword: Strain Gauge

Search Result 573, Processing Time 0.029 seconds

A Study of the Measurement of Nonwoven Geotextile Deformation with Strain Gauges (스트레인 게이지를 이용한 부직포의 변형거동 계측에 관한 연구)

  • Won, Myoung-Soo;Kim, You-Seong;Kim, Hyeong-Joo;Park, Byung-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.25-32
    • /
    • 2007
  • Because of the increasing use of clayey soil as the backfill in reinfurced soil structures and embankments, nonwoven geotextiles of drain capability have been receiving much attention. However, there are few studies on the deformation behavior analysis of nonwoven geotextiles in reinforced soil structures in the site because nonwoven geotextiles which have low tensile stiffness and higher deformability than geogrids and woven geotextiles, are difficult to measure their deformation by using strain gauges. In this study, it was suggested that a new and more convenient method could measure the deformation behaviour of nonwoven geotextile using a strain gauge and examine the availability of the method by conducting laboratory tests and applying to two geosynthetics reinforced soil (GRS) walls in the site. The result of wide-width tensile test conducted under confining pressure of 70 kPa shows that the local deformation of nonwoven geotextile to be measured with strain gauges has a similar pattern to the total deformation measured with LVDT. In the GRS walls, nonwoven geotextile shows a larger deformation range than the woven geotextile and geogrid. However, the deformation patterns of these three reinforcement materials are similar. The function of strain gauges attached to nonwoven geotextile in the walls works normally for 16 months. Therefore, the method proposed in this study for measuring nonwoven geotextile deformation using a strain gauge has proved useful.

The Fabrication of Chromiun Thin-Film Strain Gauges and Its Characteristics (크롬박막 스트레인 게이지의 제작과 그 특성)

  • 김정훈;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.343-346
    • /
    • 1997
  • This paper presents the basic characteristics of Cr thin-film, which were deposited on glass by DC magnetron sputtering. The optimized deposition condition of Cr thin-film strain gauges were input power 7w/cm$^2$and the Ar working pressure was 9mtorr. GF(Gauge Factor), TCR(Temperature Coefficient of Resistance) and TCS(Temperature Coefficient of Sensitivity) of Cr thin-film strain gauges were 5.86, 400 ppm/$^{\circ}C$ and 0 ppm/$^{\circ}C$, respectively.

  • PDF

A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges (변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구)

  • Hahn, Hyun Gyu;Ahn, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2012
  • This study aimed to develop a Structural Health Monitoring System for steel beams in the manner of suggesting and verifying a theoretical formula for displacement estimation using strain gauges, and estimating the loading points and magnitude. According to the results of this study, it was found that when a load of 160kN (56% of the yield load) was applied, the error rate of the deflection obtained with a strain gauge at the point of maximum deflection compared to the deflection measured with a displacement meter was within 2%, and that the estimates of the magnitude and points of load application also showed the error rate of not more than 1%. This suggests that the displacement and load of steel beams can be measured with strain gauges and further, it will enable more cost-effective sensor designing without displacement meter or load cell. The Structural Health Monitoring System program implemented in Lab VIEW gave graded warnings whenever the measured data exceeds the specified range (strength limit state, serviceability limit state, yield strain), and both the serviceability limit state and strength limit state could be simultaneously monitored with strain gauge alone.

Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors (광섬유 센서를 이용한 구조물의 열변형 및 온도 측정)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

Strain Analysis using Fourier Transform Grid Method and Its Image Processing (퓨리에 변환 격자법과 화상 처리를 이용한 스트레인 해석)

  • Yang, In-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.3
    • /
    • pp.165-171
    • /
    • 1992
  • 진동하는 구조물을 설계할 때에는 그 구조물 중의 Strain이나 응력이 최대가 되는 장소나 시각을 알 필요가 있다. 지금까지의 Strain 해석에는 Strain gauge 등과 같은 접촉법이 많이 이용되고 있다. 더우기, 접촉법으로 대변형 진동을 하는 물체의 Strain을 해석하는 것은 곤란하다. 최근에는 비접촉법으로 Strain 분포를 해석하기 위해 화상처리를 이용한 계측이 행하여지고 있다. 이들의 Strain 분포를 측정하는 광학적인 방법으로는 격자법, Moire법, 홀로 그랩픽 간섭법 등이 있다. 특히 대변형이나 대Strain을 해석하는 데에는 격자법이 많이 이용되고 있는데, 종래의 격자법은 Data를 처리하는 데에 많은 시간과 노력이 소요되고 작업도 매우 복잡하며, Data의 수도 제한이 되어서 구조물의 분포의 해석 정도에 큰 영향을 미치게 된다. 본 논문 에서는 스테레오법을 이용해서 2차원 격자를 붙인 시료표면의 각 점의 3차원 좌표를 계측하고, 또 Fourier 변환 격자법을 적용하여 촬영된 2차원 격자의 화상에서 위상치를 구한다. 그리고 물체의 변형 전후의 대응 관계의 화상에서 3차원 형상과 Strain 분포를 해석하는 방법을 제안한다. 이 방법을 이용하면 진동하는 구조 물의 3차원 변위분포, Strain 분포를 정도 좋게 해석할 수가 있다.

  • PDF

Evaluation of Thermal Characteristics in Association with Cement Types in Massive Concrete Structure (매스콘크리트 구조물에서의 시멘트 종류별 수화발열 특성 평가)

  • 김상철;강석화;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.6
    • /
    • pp.3-12
    • /
    • 1999
  • The larger, loftier and more highly strengthened the recent structures become, the greater attention is paid to the problem of thermal crack occurrence associate with hydration heat. As one of methods to solve the problem, a care has been taken to the improvement of construction such as the application of pre-cooling or pipe-cooling, adjustment of concrete block size, concrete placement timing, joint arrangement and so on. But it is expected that a proper selection of cement shall additionally contribute to the control of thermal cracks. In this study, thus, we selected 4 types of cements such as Type V for anti-sulphate, blast furnace cements (slag content of 45% and 65% respectively)and ternary blended low heat cement, and carried out mock-up tests. In every assigned time, temperatures and thermal stresses were measured and calculated from raw data. As a result of measurement, it was found that the magnitude of hydration heat is in order of blast furnace slag cement. Type V and ternary blended low heat cement. Results of thermal stresses were same as the order of temperature. In addition, thermal stresses calculated from the data of strain gauges showed almost similar to those measured from effective stress gauges only when strain values were adjusted properly in accordance with initial time of stress appearance. Theoretical results agreed well with the measured values comparatively, but showed slight differences. It is inferred that these differences shall be reduced if more tests capable of evaluating thermal characteristics of concrete are carried out.

Strain Analysis of Crust at the Stabilization Stage Using and Applied Statistical Analysis

  • Kim, Hyeong-Sin;Yun, Hyun-Seok;Chae, Byung-Gon;Choi, Jung-Hae;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.9-20
    • /
    • 2015
  • A strainmeter goes through a period of instability immediately after installation. To determine the stability of strainmeters installed around the Andong fault zone, South Korea, an x-MR control chart analysis and a T2 control chart analysis were conducted. The x-MR control chart analysis used an empirically determined 3σ control limit line to identify abnormal data in recently installed strain gauges. In the T2 control chart analysis, the control limit line was set at a confidence of 95%. A comparison of the early stage of measurement with the terminal stage of measurement for three months after installation indicates that stabilization depends on the location and direction of each strain gauge in x-MR control chart analysis. In the T2 control chart analysis, the number of values exceeding the control limit line decreased as the terminal stage was approached. Based on these results, it is suggested that the 3σ control limit line of an x-MR control chart can be used as a standard for single gauge stability, and that the 95% confidence limit of a T2 control chart analysis could be used as the standard for the stability of multi-gauge strainmeters.