• Title/Summary/Keyword: Straight fluid

검색결과 207건 처리시간 0.02초

플러그 밸브의 포트형상 변화에 따른 유동특성 연구 (A study on the flow characteristics in a plug valve with various port shapes)

  • 최근우;박권종;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.259-264
    • /
    • 2000
  • The functions of the plug valve are the control of flow rate as well closing and opening pipe lines. Analyses on the flow characteristics in plug valve port are required to improve the performance and safety at severe operating conditions such as high-pressure and high-temperature. In this study, numerical analyses are carried out with varying the opening rate (fraction of the full open to close) of the valve and the shapes of valve Uk: straight, convex, concave and mixed shapes. The parameters influencing the flow characteristics in the valve are the discharge coefficient( $C_v$) and the resistance coefficient( K). Therefore, the distributions of static pressure, velocity vector and stream lines are investigated, and $C_v$ and K are calculated in each opening rate and shape. In case of full open, the static pressure passed through the valve port has almost been recovered. However, in case of other opening rates, the pressure does not permanently regained due to pressure drop leading to loss. This phenomenon in each shape of the valve shows the different behaviors. Calculation results show that the mixed shape has the best flow attribute.

  • PDF

Soroban grid 기반 CIP법을 이용한 자유표면 유동해석 (FREE SURFACE FLOW ANALYSIS BY SOROBAN GRID BASED CIP MEHTOD)

  • 임효남
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, we provide a comprehensive review of the CIP(Constrained Interpolation Pro file/Cubic Interpolated Propagation) method with a pressure-based algorithm that is known as a general numerical solver for soled liquid, gas and plasmas. And also we introduce a body-fitted grid system(Soroban grid) for computation of strongly nonlinear marine hydrodynamic problems such as slamming water on deck, wave impact by green water. This grid system can keep the third-order accuracy in time and space with the help of the CIP method. The grid system consists of the straight lines and grid points. In the 2-dimensional grid case, each grid points moving in these lines like abacus - Soroban in Japanese. The length of each line can be different and the number of grid points in each line can be different. Mesh generation and searching of upstream departure point are very simple and possible to mesh-free treatment. To optimize computation of free-surface and multi-fluid flows, We adopt the C-CUP method. In most of the earlier computations, the C-CUP method was used with a staggered-grid approach. Here, because of the mesh free nature of the Soroban grid, we use the C-CUP method with a collocated-grid approach.

  • PDF

2차유동이 평판후류의 난류열전달에 미치는 영향 (Effects of the secondary flow on the turbulent heat transfer of a flat plate wake)

  • 김형수;이준식;강신형
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.417-427
    • /
    • 1998
  • The effect of secondary flow on the heat transfer of a turbulent wake generated by a flat plate was experimentally investigated. The secondary flow was induced in a curved duct in which the flat plate wake generator was installed. All three components of turbulent heat flux were measured in the plane containing the mean radius of curvature of the curved duct. The results showed that mean temperature profiles deviate from the similarity of the straight wake because of the cold fluid transported from the free-stream. The half-width of the mean temperature profile increased rapidly by upwash motion of the secondary flow. The changes to turbulence structure caused by the secondary flow show more pronounced effect on heat transport than on momentum transport. This is because the response to the variation of flow conditions is delayed in temperature field. Negative production of the turbulent heat flux is observed in the inner wake region. From the conditional averaging, it has been found that the negative production of the turbulent heat flux is generated due to a mixing process between the hot and low momentum eddies occupied in the inner wake region and the cold and high momentum eddies in the potential region.

표면 조도와 곡률 반경에 대한 U-자관 압력 손실의 상관관계 (THE CORRELATION OF PRESSURE DROP FOR SURFACE ROUGHNESS AND CURVATURE RADIUS IN A U-TUBE)

  • 박정후;장세명;이신영;장강원
    • 한국전산유체공학회지
    • /
    • 제20권1호
    • /
    • pp.39-46
    • /
    • 2015
  • In this research, we studied the pressure drop affecting on the internal surface roughness and the curvature radius of a U-tube, which is used for the cooling system in PWR(Pressurized Water Reactor). Using ANSYS-FLUENT, a commercial code based on CFD(Computational Fluid Dynamics) technique, we compared a Moody chart with the Darcy friction factor changed by a range of various surface roughness and Reynolds numbers of a straight pipe model. We studied the effect giving variation about a range of various surface roughness and the curvature radius of the full scale U-tube model. The material of the heat transfer tube is Inconel 690 used in the steam generator. We compared the velocity distribution of selected 4 locations, and derived the correlation between the surface roughness and the pressure drop for the U-tube of each representative curvature radius using the linear regression method.

전단간섭계와 적외선열화상을 이용한 감육 직관의 결함검출 (Defect Detection of Wall Thinned Straight Pipe using Shearography and Lock-in Infrared Thermography)

  • 김경석;정현철;장호섭;김하식;나성원
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.55-61
    • /
    • 2009
  • The wall thinning defect of nuclear power pipe is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid. This type of defect becomes the cause of damage or destruction of in carbon steel pipes. Therefore, it is very important to measure defect which is existed not only on the welding part but also on the whole field of pipe. This study use dual-beam Shearography, which can measure the out-of-plane deformation and the in-plane deformation by using another illuminated laser beam and simple image processing technique. And this study proposes Infrared thermography, which is a two-dimensional non-contact nondestructive evaluation that can detect internal defects from the thermal distribution by the inspection of infrared light radiated from the object surface. In this paper, defect of nuclear power pipe were, measured using dual-beam shearography and infrared thermography, quantitatively evaluated by the analysis of phase map and thermal image pattern.

조석효과에 의한 항구 모델 주위의 유동 및 물질전달에 관한 실험적 연구 (Experimental study on the fluid flow and material transport around a harbor driven by the tidal effect)

  • 서용권;문종춘;강종대
    • 한국해양공학회지
    • /
    • 제10권1호
    • /
    • pp.100-107
    • /
    • 1996
  • In this paper, we report the results of the experimental study on the flow and the mass transport around a square harbor driven by a tidal effect. The model harbor is composed of a uniform water-depth with a straight breakwater. The harbor is connected to the outer ocean by an entrance region having the same shape as the harbor. We investigated two cases, one having another breakwater in the place between the entrance region and the outer ocean, and the other without it, The surface and bottom flow patterns of the model container are visualized by using light particles and dye, respectively. It was shown that the inner harbor and the entrance region have well-organized, large vortical residual flows, and the material transport between the entrance and outer region is however significantly different for two cases; when the breakwater is built between the two regions, the transport is far better than that without it, which is clearly contrary to our common sense that the breakwater would block the dispersion of the materials between the harbor and the outer ocean.

  • PDF

Design of partial emission type liquid nitrogen pump

  • Lee, Jinwoo;Kwon, Yonghyun;Lee, Changhyeong;Choi, Jungdong;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.64-68
    • /
    • 2016
  • High Temperature Superconductor power cable systems are being developed actively to solve the problem of increasing power demand. With increases in the unit length of the High Temperature Superconductor power cable, it is necessary to develop highly efficient and reliable cryogenic pumps to transport the coolant over long distances. Generally, to obtain a high degree of efficiency, the cryogenic pump requires a high pressure rise with a low flow rate, and a partial emission type pump is appropriate considering its low specific speed, which is different from the conventional centrifugal type, full emission type. This paper describes the design of a partial emission pump to circulate subcooled liquid nitrogen. It consists of an impeller, a circular case and a diffuser. The conventional pump and the partial emission pump have different features in the impeller and the discharge flow passage. The partial emission pump uses an impeller with straight radial blades. The emission of working fluid does not occur continuously from all of the impeller channels, and the diffuser allows the flow only from a part of the impeller channels. As the area of the diffuser increases gradually, it converts the dynamic pressure into static pressure while minimizing the loss of total pressure. We used the known numerical method for the optimum design process and made a CFD analysis to verify the theoretical performance.

극세관 헬리컬 코일형 열교환기에 관한 연구 (A Study on the Helically Coiled Heat Exchanger of Small Diameter Tubes)

  • 김주원;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1492-1499
    • /
    • 2001
  • In order to develop the compact and flexible heat exchangers, we made the helically coiled heat exchangers. They can be manufactured with small diameter copper tubes without the need for fins; inner diameter=1.0 mm, straight tube length=1.5 m. The experiments were carried out with the following conditions; evaporation pressure=0.6 MPa, air velocity=0.7 ∼ 1.7 m/s, and working fluid=R-22. Pressure drop and heat transfer coefficient of heat exchangers were experimented according to the air velocity. The results of heat transfer coefficient show a 35% beneficial increase fur these heat exchangers over the other covered fin-tube heat exchangers. A cooling capacity of about 3 kW was obtained with an air velocity of 1.5 m/s. The distribution header has also been designed fur efficient distribution of refrigerant flow.

미소블록에 의한 교차 회전유동과 미소유로에 의한 박층유동을 이용한 정적 혼돈 미소유체 혼합기에 관한 연구 (Static Chaos Microfluid Mixers Using Alternating Whirls and Laminations)

  • 장성환;조영호
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1549-1556
    • /
    • 2004
  • We have deigned, fabricated and compared four different types of static chaos microfluid mixers, including the mixers using straight channel flow, microblock-induced alternating whirl flow, microchannel-induced lamination flow, and combined alternating whirl-lamination flow. Among them, the alternating whirl-lamination (AWL-type) mixer, composed of 3-D rotationally arranged microblocks and dividing microchannels fabricated by conventional planar lithography process, is effective to reduce the mixing length over wide flow rate ranges. We characterize the performance of the fabricated mixers, through the flow visualization technique using phenolphthalein solution. We verify that the AWL-type microfluid mixer shows the shortest fluid mixing length of 2.8mm∼5.8mm for the flow rate range of Re=0.26∼26 with the pressure drop lower than 5kPa. Compared to the previous mixers, requiring the mixing lengths of 7∼17mm, the AWL-type microfluid mixer results in the 60% reduction of the mixing lengths. Due to the reduced mixing lengths within reasonable pressure drop ranges, the present micromixers have potentials for use in the miniaturized Micro-Total-Analysis-Systems($\mu$TAS).

점근해석을 이용한 확대형 채널 내의 천음속 예혼합 연소에 관한 연구 (A Study of Transonic Premixed Combustion in a Diverging Channel Using Asymptotic Analysis)

  • 이장창
    • 한국항공우주학회지
    • /
    • 제33권8호
    • /
    • pp.75-83
    • /
    • 2005
  • 확대형 채널 내의 정상 천음속 희박 예혼합 연소에 대해 점근해석을 이용하여 연구하였다. 이 모델은 근음속의 유동 속도와 일직선 채널로부터 벗어난 작은 형상변화 그리고 1단 1차 Arrhenius 화학 반응율에 의한 적은 열 방출 사이에서 일어나는 비선형 상호작용에 대하여 탐구하였다. 반응유체 유동은 연소 가스의 질량 분율을 계산하는 상미분 방정식과 연계된 비균질 천음속 미교란 방정식(TSD)을 사용하여 묘사하였다. 또한 점근해석으로부터 반응유체 유동 문제를 지배하는 상사 파라미터들을 유도하였다. 수치 결과들은 대류와 화학반응 그리고 형상효과 사이에 일어나는 복잡한 비선형 상호작용과 유동에 미치는 이것의 영향 등이 잘 나타나 있다.