• 제목/요약/키워드: Straight

검색결과 4,098건 처리시간 0.031초

멀리건의 견인을 동반한 하지직거상 기법이 요통 환자의 제한된 하지직거상에 미치는 즉각적인 영향에 관한 연구 (A Study on the Immediate Effects of Mulligan's Straight Leg Raise with Traction Technique on Limited Straight Leg Raise of Low Back Pain Patients)

  • 최율정;윤홍일;이준용
    • 대한정형도수물리치료학회지
    • /
    • 제19권1호
    • /
    • pp.55-61
    • /
    • 2013
  • Background: The purpose of this study was to investigate the immediate effects of mulligan's straight leg raise with traction technique on angle of passive straight leg raise and length of hamstring muscle in patients with low back and radiate pain. Methods: Thirty one subjects participated in this study. The subjects were assigned to either the low back pain group (n=17) or the radiate pain group (n=14). Subjects in both groups received 3 times mulligan's straight leg raise with traction. All subjects were examined for the range of motion of lower extremity. The range of motion of lower extremity was composed of angle on straight leg raise and 90-90 straight leg raise. The range of motion of lower extremity was measured using a goniometer. Results: After 3 times of mulligan's straight leg raise with traction, significant improvements on the angle of straight leg raise and 90-90 straight leg raise were observed in the both groups (p<.05). However, there are no significant difference was observed between groups. Conclusion: These results suggest that mulligan's straight leg raise with traction provides an immediately effective in range of motion of lower extremity in patients with low back pain as well as radiate pain. Although more research is required on the effects of long-term mulligan's straight leg raise with traction on range of motion of lower extremity, our results can be useful to establish the standard parameters for range of motion of lower extremity in the clinical setting.

  • PDF

엉덩관절 모음을 동반한 뻗은다리 올림 시 안쪽넓은빗근의 선택적 활성화를 더 이끌어낼 수 있는가? (Can Hip Adduction induce more Selective Activation of the Vastus Medialis Obliquus during Straight Leg Raise Exercise?)

  • 송성인;배창환;김상현
    • 대한정형도수물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.23-29
    • /
    • 2023
  • Background: There is still controversy as to whether hip external rotation and dorsiflexion selectively activate the vastus medialis obliquus (VMO) during straight leg raise exercise. Due to the anatomical characteristics, hip adduction must be preceded to activate the VMO. In this study, the activities of the rectus femoris (RF), vastus lateralis (VL), VMO were measured by adding the hip adduction movement to the straight leg raise exercise with hip 45° external rotation and straight leg raise exercise with hip 45° external rotation and dorsiflexion. Through this, we want to find out whether the VMO is selectively activated. Methods: Thirteen healthy participants performed straight leg raise exercise with hip 45° external rotation, straight leg raise exercise with hip 45° external rotation and dorsiflexion, straight leg raise exercise with hip 45° external rotation and adduction, straight leg raise exercise with hip 45° external rotation and adduction and dorsiflexion was randomly performed. Through this, EMG data of the RF, VL, VMO were collected. Results: During the straight leg raise exercise, hip adduction increased the activity of the VMO and VL, no significant difference was found(p>.05). However, in the VMO/VL ratio, straight leg raise exercise with hip 45° external rotation and adduction and dorsiflexion activated the VMO and the VL at a ratio of about 1:1, It showed a significantly higher rate than straight leg raise exercise with hip 45° external rotation(p<.05). Conclusion: During the straight leg raise exercise, hip adduction is considered to be an important movement that can selectively induce the activity of the VMO. Therefore, follow-up studies on this should be conducted.

  • PDF

스트레이트 퍼머 및 매직 스트레이트 퍼머에 의한 모발의 변화 (Changes of the hair's by straight permanent and magic straight permanent)

  • 이정은;홍정민
    • 한국패션뷰티학회지
    • /
    • 제1권1호
    • /
    • pp.133-142
    • /
    • 2003
  • As you see, there's no difference of the hair's before and after Magic straight permanent on the example A's hair's thickness, the rate of the tense and the C's rate of the tense, but we can find that there are a lot of difference of the A's strength of the hair, the B's hair's thickness, the strength of the hair, the rate of the tense, the C's hair's thickness, and the strength of the hair on the before and after the Magic straight permanent. That is to say, there are more damage on the condition of normal hair than the one after the Magic straight permanent. On the change of the hair's physical character, before the permanent, the hair's schedule was regular and had the healthy head skin of clear mutual boundary But after the Magic straight permanent wave, the hair's schedule changed to unregural, had unclear mutual boundary of the head skin and the schedule was taken off so the cortex showed up and so on, every condition of the damage was very heavy. On the effect of the treatment, even though it gaves the worth condition of the hair, after the Magic straight permanent formally the change of the hair gives the beautiful straight.

  • PDF

Continuous straight archwire에 의하여 발생하는 force system의 분석 (Analysis of force system developed by continuous straight archwire)

  • 최광철;손병화
    • 대한치과교정학회지
    • /
    • 제26권3호
    • /
    • pp.281-290
    • /
    • 1996
  • Edgewise bracket에 continuous straight archwire를 장착 했을 때 각 bracket에 발생 하는 force system은 statically indeterminate system이기 때문에 임상적으로 측정이 어렵다. 이에 본 연구는 linear beam theory를 도입하여 full arch에 straight wire가 장착된 경우 geometry(a/b), 재질, 단면의 모양, interbracket distance에 관계없이 발생 가능한 모든 상태를 설명할 수 있는 식을 유도하고 일례의 분석을 통하여 다음과 같은 결과를 얻었다. 1. Bilateral fixed beam의 양끝에서 발생하는 force system을 알 수 있는 계산식을 얻었다. 2. 이를 이용하여 continuous straight archwire가 장착된 경우 각 치아에 발생하는 force system을 알 수 있다. 3. Continuous straight archwire장착시 영구변형의 발생여부와 발생위치를 예측 할 수 있다.

  • PDF

폐포가 달린 도관 내에서의 입자의 분산 (DISPERSION OF AN AEROSOL BOLUS IN THE ALVEOLAR DUCT)

  • 이동엽;이진원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.697-698
    • /
    • 2002
  • The dispersion of an aerosol bolus in acinus is analyzed numerically. Model geometry is a straight duct surrounded by an axisymmetric semicircular annulus which is expanding or contracting with breathing. Unsteady Wavier-Stokes equation is solved by CFX-F3D, an FVM commercial code and the trajectory of massless particle Is computed by Lagrangian method. For steady flow with no wall motion, mean velocity of aerosol bolus in alveolated duct is a little smaller than that in straight duct and dispersion in alveolated duct is comparable with the dispersion in straight tube. For expanding duct mean velocity of aerosol bolus approaches half of that in straight tube and effective diffusivity is smaller than that of straight tube. For contracting duct mean velocity of aerosol bolus becomes slightly larger than that in straight tube and effective diffusivity is comparable with the case of straight tube.

  • PDF

구순구개열 환자에 있어 직선봉합법의 역할 (Revisited Straight Line Technique for Unilateral Cleft Lip)

  • 서병무
    • 대한구순구개열학회지
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 2008
  • The variations of cleft lip deformities imposed the difficulty to the surgical correction for them. Straight line technique for cleft lip surgery has been ignored quite long since other techniques were developed. Initially the straight line technique was introduced and widely accepted because it is simple and easy to perform during the period of no adequate anesthetics. But it was abandoned for its several shortcomings such as tighten lip, vermilion notching, anatomical distortion, and wound contractures. Recently, some groups advocated the usefulness of straight line technique which has a significant modification from its original form. Additionally the variable degree of cleft lip deformity allows simple straight line closure for those patients. Here a case of simple straight line technique was presented and discussed for its reliability and plausible results as well.

  • PDF

구조해석에 의한 디지털 곡선의 분리 (Segmentation of Digital Curves by Structural Analysis)

  • 류승필;권오석;김태균
    • 대한전자공학회논문지
    • /
    • 제26권12호
    • /
    • pp.1984-1994
    • /
    • 1989
  • Techniques for approximating digitalcurves by polygonal lines are a valuable tool for image analysis and data compression. S. Shilien proposed a method for segmenting a digital curve into digital straight line segments digital straight line segments which are not satisfied with the structural properties, and have more than one break point by Shilien's method. Here, the structural representation of digital straight lines and digital staight line segments is described. And a method for segmenting a digital curve into digital straight line segments which are not satisfied with the structural properties, and have more than one break point by Shilien's method. Here, the structural representation of digital straight lines and digital staight line segments is described. And a method for segmenting a digital curve into digital straight line segments which may be not satisfied with the structural properties is proposed. The number of break points extracted by this method is less than that by S. Shilien's method from the digital curve which includes the digital straight line segments not satisfied with the structural properties.

  • PDF

A Study of Hair Damage by Magic Straight Perm

  • Lim, Sun-Nye
    • Applied Microscopy
    • /
    • 제42권3호
    • /
    • pp.129-135
    • /
    • 2012
  • In this study, the changes in hair quality before and after Magic straight perm have been evaluated through a hair damage measurement method. For this, a healthy high school student's (age18 years) wavy hair was selected and permed on the left and right sides. Then, the changes caused by physical methods which were applied during the fl at iron-based Magic straight perm were evaluated based on the hair damage measurement method before and after the Magic straight perm. According to the protein release test after the Magic straight perm, 1.26% in average and 0.14% was observed in Cool Magic straight perm sample. In a field emission scanning electron microscopy (FE-SEM) test, saw teeth-shaped partial desquamation of cuticle cells and impurities were observed in the warm-treated hair sample. In atomic force microscope (AFM), line-profile is a method to represent roughness data on hair. According to analysis on 3-dimensional (3D) images, the hair with Cool Magic straight perm was lower than the hair with Warm Magic perm in terms of the color change of 3D images. In addition, vertical changes were observed in the hair with Cool Magic perm. As a result, irregular surface roughness was observed. This study proposed a method to minimize hair damage by cooling down the heat with the cool hair straightener as soon as the Warm Magic was finished.

주성분 분석과 허프 변환을 이용한 직선 검출 (Straight Line Detection Using PCA and Hough Transform)

  • 오정수
    • 한국정보통신학회논문지
    • /
    • 제22권2호
    • /
    • pp.227-232
    • /
    • 2018
  • 직선 검출을 위한 대표적인 알고리즘인 허프 변환에서 잡음이 있거나 복잡한 영상에서 생성되는 방대한 에지 화소들은 상당한 계산량과 의사직선을 야기한다. 본 논문은 기존 허프변환을 개선하기 위해 2 단계 직선 검출 알고리즘을 제안한다. 첫 번째 단계에서 제안된 알고리즘은 영상을 겹치지 않는 블록들로 나누고, 주성분 분석(PCA)을 이용해 블록 내 에지 화소들의 직선과 관련된 정보를 검출한다. 두 번째 단계에서 직선과 관련된 화소들에 기울기 제한된 허프변환을 수행하여 직선들을 검출한다. 모의실험 결과들은 제안된 알고리즘이 부가적인 계산이 다소 필요하지만 불필요한 에지 화소들을 줄이고 기울기 영역을 제한하여 ${\rho}$ 계산의 평균 94.6% 줄여주고 의사직선 검출을 방지하는 것을 보여주고 있다.

Polyjet방식 3D 프린터를 이용한 스트레이트 베벨기어의 제작 특성에 관한 실험적 연구 (Experimental Study on Production Characteristics of Straight Bevel Gear using a Polyjet Method 3D Printer)

  • 김해지
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.63-68
    • /
    • 2015
  • Recently, 3D printer technologies have been used in many research efforts for high precision manufacturing. In particular, the rapid prototyping technology has been developing rapidly, because it can be manufactured in a short time with a 3D designed shape. This paper relates to the production characteristics of the straight bevel gear designed using a 3D print using the PolyJet method. The characteristics of a 3D printed straight bevel gear were compared with a machined straight bevel gear. The accuracy of the produced straight bevel gear was evaluated by backlash, meshing pattern, face angle, root angle, and surface roughness.