• Title/Summary/Keyword: Story height

Search Result 199, Processing Time 0.026 seconds

Experimental Study on the Infilling Characteristics of CFT Column Infilled by Pumping-Up Below (하부압입공법에 의한 콘크리트 충전강관(CFT)기둥의 충전특성에 관한 실험적 연구)

  • Kim, Myoung Mo;Jeon, Sang Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.375-383
    • /
    • 2002
  • To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.

Flexural Capacity of the Profiled Steel Composite Beams -Deep Deck Plate- (강판성형 합성보의 휨성능 평가 -춤이 깊은 합성데크-)

  • Heo, Byung Wook;Kwak, Myong Keun;Bae, Kyu Woong;Jeong, Sang Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.247-258
    • /
    • 2007
  • This paper describes the results of an experimental study on the new type of encased composite beams that use deep deck plates, which could reduce the story height of buildings by controlling the bottom flange of steel beams. The profiled steel beam was thus developed. It was advantageous to the long span of the buildings. Seven full-scale specimens were constructed, and simply supported bending tests were conducted on the encased composite beams with different steel plate thicknesses, with and without shear studs, reinforcing bars, and web openings. The test results showed that the encased composite beams that were developed in this study had sufficient composite action without additional shear connectors due to their inherent shear-bond effects between the steel beams and concrete.

The Eigenvalues and Their Relationships for the Rectangular Frame (4각형 골조의 고유치와 고유치 간의 관계)

  • Lee, Soo-Gon;Kim, Soon-Cheol;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.139-150
    • /
    • 2005
  • Finite element method is applied to the determinations of the two eigenvalues(the elastic critical load and the natural frequence of lateral vibrations) of single story-3 equal bay rectangular frame. The analysis parameters are taper parameter ${\alpha}$ for column, and beam span to column height ratio, ${\beta}$ and second moment area ratio of beam to column, ${\Upsilon}$. Support condition at the column base and sway condition at the column top are also considered in the stability analysis of frame. The changes in the coefficient of eigenvalue are represented by algebraic function of analysis parameter. The coefficients estimated by the proposed algebraic function show good agreement with those determined by finite element method, which suggest the design aid role of the proposed function. By increasing the column axial forces step by step, the corresponding frequencies are also determined, which makes one examine or confirm the relationship suggested by other studies.

Officetel Rent Determinants in Seoul (서울시 오피스텔의 임대료 결정요인에 관한 연구)

  • Koo, Dong-Hoe;Yang, Seung-Chul
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.3
    • /
    • pp.654-666
    • /
    • 2004
  • The function of officetel has been changed from office use to residential use since 1980s. The construction of officetel was relatively increased in 1991, has been decreased in the middle of the 1991, and has been increased after 1996. This paper is an empirical examination of officetel rent determinants in Seoul. Hedonic regression analysis provides the basic framework for this study. The major rent determinants are the preferable location of buildings, the ratio of private use area to the building area. residential use. The officetel rents are likely to increase at an increasingly rate with respect to these variables. The significant and positive determinants that impact rents is the building story height for the officetel for business use, and the ratio of private use area to the building area for the officetel for residential use.

  • PDF

A Study on the Systematic Construction of the Utility Space in General Hospital (국내 종합병원 Utility Space의 체계 구축에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: In terms of the flexibility in hospital architecture, there are fixed elements of hospital architecture: mechanical, electrical, aeration rooms and shafts, which are the main utility spaces. Thus, it is necessary to recognize the utility space as a system that helps internal functions and flexible internal changes. This study analyzes the notion of the main utility space in hospital architecture and the architectural planning features of the main utility spaces as the system in the design process of the recently built hospitals. Methods: The design factors are extracted comparing two hospitals' plans in each stage and the systematic characteristics of utility spaces are analyzed accordingly. The opinions gathered from interviews of practitioners, architects and facility planning experts directly involved in the architecture design process are analyzed and reflected in the results. Results: Planning for utility spaces should be accompanied by the architectural plan from the basic design process, and proceeded with recognizing utility spaces as a system, which is a fixed element. Utility spaces are highly organically connected. Horizontal and vertical distribution of air chambers can reduce the length and number of ducts, and thus save story height, and reduce the number of shafts, the vertical connection passage. This is advantageous in securing the variable area, which is the ultimate objective of the system-centered hospital architecture plan. Implications: Thereby aims to provide fundamental data on systematic utility space planning in the hospital architecture planning.

Flexural Capacity of the Profiled Steel Composite Beams with Truss Deck Plate (트러스 데크를 사용한 강판성형 합성보의 휨성능 평가)

  • Heo, Byung Wook;Kwak, Myong Keun;Bae, Kyu Woong;Jung, Sang Min;Kang, Suk Kuy
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.413-423
    • /
    • 2007
  • Slimfloor composite-beam systems could considerably reduce the story height of a building if the steel beam would be installed deep into the concrete floor slab. However, as the depth of the steel beam's installation is limited, it cannot cope with the various demands of building systems. To address this problem, a profiled steel beam section that can control the depth of the steel beam's and slabs' installation was developed in this study. Presented herein are the results of an experiment that was conducted focusing on the flexural behavior of the partially connected composite beams with profiled steel beams encased in composite concrete slabs. Five full-scale specimens with different slab types, with or without shear connection and reinforcement bars, were constructed and tested in this study. As a result, the shear bond stress without an additional shear connection was found to be $0.20{\sim}0.76N/mm^2$due to the inherent mechanical and chemical bond stress.

Reconstruction of Long Term Neglected, Complicated Scalp and Calvarial Defects with Subdural Abscess Using Latissimus Dorsi Myocutaneous Free Flap: A Case Report (장기간 방치된 경막하 농양을 동반한 복합 두피 및 두개골 결손 환자에서 광배근 유리 근피부피판을 이용한 치험례)

  • Noh, Yongjoon;Lee, Sang Hyung;Jeong, Eui Cheol;Park, Ji Ung
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.2
    • /
    • pp.107-110
    • /
    • 2011
  • Purpose: There have been few case reports regarding treatment plans for long-term, neglected scalp defects and calvarial defects with subdural abscess. The purpose of this case report is to present our experience with a free latissimus dorsi musculocutaneous flap for scalp and calvarial defects and to discuss flap options in comparison with a literature review. Methods: A 60-year-old man who fell down from a four-story-height that resulted in a craniotomy in 1979; he visited our outpatient clinic for a chronic, purulent scalp and calvarial defects with unidentified artificial bone. The artificial bone was removed by a neurosurgeon and reconstructed with a free latissimus dorsi musculocutaneous flap. The deep temporal artery was used as a recipient artery. The postoperative flap status was excellent until the 6th day post-operation when the patient experienced a seizure, and an arterial insufficiency occurred at the flap probably due to an arterial spasm. Emergency exploration with arterial re-anastomosis was performed and the flap status was stabilized. Results: Complete wound healing was achieved after 3 weeks without infectious and systemic postoperative complications. During the 6 month follow-up period, there were no complications. Conclusion: We suggest the latissimus dorsi myocutaneous free flap as a good treatment option for a chronic, purulent, complicated scalp with calvarial defect, as a well as treatment for an acute traumatic defect.

Structural performance and SWOT analysis of multi-story buildings of lightweight reinforced concrete comprising local waste materials

  • Walid A., Al-Kutti;A.B.M. Saiful, Islam;Zaheer Abbas, Kazmi;Mahmoud, Sodangi;Fahad, Anwar;Muhammad, Nasir;Muhammad Arif Aziz, Ahmed;Khalid Saqer, Alotaibi
    • Earthquakes and Structures
    • /
    • v.23 no.6
    • /
    • pp.493-502
    • /
    • 2022
  • In recent decades, infrastructural development has exploded, particularly in the coastal region of Saudi Arabia. The rising demand of most consumed aggregate in construction can be effectively compensated by the alternative material like scoria which lavishly exists in the western region. Scoria is characterized as lightweight aggregate beneficially used to develop lightweight concrete (LWC) - a potential alternative of normal weight concrete (NWC) ensuring reduction in the structural element's size, increase in building height, comparatively lighter foundation, etc. Hence, the goal of this study is to incorporate scoria-based structural lightweight concrete and evaluate its impact on superstructure and foundation design beside contributing to the economy of construction. Fresh, mechanical, and rheological properties of the novel LWC have been investigated. The structural analyses employ the NWC as well as LWC based structures under seismic and wind loadings. The commercial finite element package - ETABS was employed to find out the change in structural responses and foundations. The cost estimation and SWOT analysis for superstructure and foundation have also been carried out. It was revealed that the developed LWC enabled a more flexible structural design. Notable reduction in the steel and concrete prices of LWC might be possible in the low-rise building. It is postulated that the cost-effective and eco-friendly LWC will promote the usage of scoria as an effective alternative in Saudi Arabia and GCC countries for structurally viable LWC construction.

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

Shear Behavior of Reinforced Concrete Deep Beams with Web Openings (개구부를 갖는 철근콘크리트 깊은 보의 전단거동)

  • 이진섭;김상식
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.619-628
    • /
    • 2001
  • In building construction, openings of the story-height deep beams are usually required for accessibility and service lines such as air conditioning ducts, drain pipes and electric units. It is known that the main parameters affecting the load bearing capacity of deep beams with web openings are size, shape, location and reinforcements of openings. However, there have been no pertinent theories and national design codes for predicting ultimate shear strength of reinforced concrete deep beams with web openings. In this study, the shear behavior of simply supported reinforced concrete deep beams with web openings subject to concentrated loads has been scrutinized experimentally. A total of 34 specimens, the geometry of openings, its reinforcements and shear span to depth ratio, being taken as the experimental variables, has been cast and tested in the laboratory. The effects of these structural parameters on the shear strength and crack initiation and propagation have been carefully checked and analyzed. From the tests, it has been observed that the failures of all specimens were due to shear mechanism and the ultimate strength of specimens varies according to the location of openings, by which the formation of compression struts between the loading points and supports are deterred. All of the test results of specimens have been compared with the formulas proposed by previous researchers. The results were closely coincident with the formulas given by Ray and Kong's equation except for some X series specimens having a larger dimension of openings beyond the geometric limits of proposed equations.