• 제목/요약/키워드: Story Shear

검색결과 536건 처리시간 0.026초

Damage detection of multistory shear buildings using partial modal data

  • Shah, Ankur;Vesmawala, Gaurang;Meruane, V.
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 2022
  • This study implements a hybrid Genetic Algorithm to detect, locate, and quantify structural damage for multistory shear buildings using partial modal data. Measuring modal responses at multiple locations on a structure is both challenging and expensive in practice. The proposed method's objective function is based on the building's dynamic properties and can also be employed with partial modal information. This method includes initial residuals between the numerical and experimental model and a damage penalization term to avoid false damages. To test the proposed method, a numerical example of a ten-story shear building with noisy and partial modal information was explored. The obtained results were in agreement with the previously published research. The proposed method's performance was also verified using experimental modal data of an 8-DOF spring-mass system and a five-story shear building. The predicted results for numerical and experimental examples indicated that the proposed method is reliable in identifying the damage for multistory shear buildings.

Impact of shear wall design on performance and cost of RC buildings in moderate seismic regions

  • Mahmoud, Sayed;Salman, Alaa
    • Earthquakes and Structures
    • /
    • 제21권5호
    • /
    • pp.489-503
    • /
    • 2021
  • This research aims to investigate the seismic response of RC shear wall buildings of 5-, 6-, 7-, 8-, 9-, and 10-story designed as conventional and ductile and located in moderate seismic zone in Saudi Arabia in accordance with the seismic provisions of the American code ASCE-7-16. Dynamic analysis is conducted using the developed models in ETABS and the design spectra of the selected zone. The seismic responses of a number of design variations are evaluated in terms of story displacements, drift, shear and moments of both conventional and ductile building models as performance measures and presented comparatively. In addition, pushover analysis is also performed for the lowest and highest building models. Cost estimate of ductile and conventional walls is evaluated and compared to each other in terms of weight of reinforcement bars. In addition, due to the complexity of design and installation of ductile shear walls, sensitivity analysis is performed as well. It is observed that conventional design considerably increases induced seismic responses as well as cost compared to ductile one.

바닥슬래브의 면내강성을 고려한 필로티 구조물의 효율적인 거동분석 (Efficient Analysis of Shear Wall Strustures with Pilotis considering the in-plane stiffness of the floor slabs)

  • 김현수;김혜숙;김현정;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.865-872
    • /
    • 2006
  • Recently, many apartment buildings in the shear wall system often has pilotis in the lower story to meet the architectural needs. If the lateral force resisting system consists of shear walls supported by columns and beams. the discontinuity at the lowest level with pilotis results in the vertical irregularity with strength and stiffness. So, there are needs to be considered tile analysis and design about column and beam bellow shear walls and the behavior and stress condition of structure by stiffness change being generated at shear walls. The purpose of this paper is to investigate the behavior of shear wall structures with pilotis using the floors modeled as rigid diaphragm or semi rigid diaphragm. Through analyses, after estimating values of the story drift, natural period, stress condition of shear walls and the forces of column, we inferred how the behavior of shear wall structures with pilotis was influenced by the floor stiffness.

  • PDF

반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 시간이력해석 (Inelastic Time History Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection)

  • 강석봉;김신애
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.313-324
    • /
    • 2010
  • 본 연구에서는 반강접 접합부 배치에 따른 구조물 거동특성을 파악하기 위하여 KBC2005 건축구조설계기준으로 비가새 5층 철골 구조물을 설계하여 모든 접합부를 완전 강접합부와 반강접 접합부로 이상화한 경우 그리고 반강접 접합부를 수직배치 및 수평배치한 경우에 대하여 비탄성 시간이력 구조해석을 실시하였다. 철골 보 및 기둥의 모멘트-곡률 관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델 그리고 철골 보, 기둥 및 접합부의 이력거동은 3-매개변수 모델을 이용하여 나타내었다. 4개 지진파에 대한 재현주기 2400년 위험수준에 해당하는 최대지반가속도와 5% 층간변위에 대한 푸쉬오버 구조해석의 최대밑면전단력 발생 최대지반가속도에 대하여 시간이력 구조해석을 실시하여 밑면전단력, 지붕층 변위, 층간변위, 접합부 요구연성도, 기둥, 보 및 접합부의 최대휨모멘트 그리고 소성힌지 분포 등을 확인하였다. 반강접 접합부를 수직적으로 외부에 배치할수록 최대밑면전단력과 층간변위는 감소하며, 수평적으로 상부층에 배치할수록 접합부 요구연성도가 감소하였다. 푸쉬오버 구조해석과 시간이력 구조해석에서 최대층간변위 발생 위치가 다르고 크기는 푸쉬오버 구조해석에서 과대평가되었다. 밑면전단력, 층간변위 및 접합부 요구연성도를 위한 가장 바람직한 반강접 접합부 배치는 수직적으로 외부에 배치하는 것이다.

편심을 가진 1/12 축소 RC 주상복합구조물의 진동대실험 (Shaking Table Tests of 1/12-Scale RC Bearing-Wall System with Bottom Piloti Stories Having Eccentric Shear-Wall)

  • 이한선;고동우;권기혁;김병현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.185-190
    • /
    • 2001
  • The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1:12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames with infilled shear wall have two different layouts of the plan : The one has symmetric plan and the other has unsymmetric plan. Then, this model was subjected to a series of earthquake excitations. The test results show that the layout of shear wall has the negligible effect on the natural period and the base shear coefficient, but great effect on the failure mode of beam-column joint at flexible side frame.

  • PDF

단부에 설비덕트를 포함하는 새로운 더블티 전단실험II (Shear Test II on New Modified Double Tee Slabs including Service Ducts at the Ends)

  • 김연수;유정욱;이보경;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.267-270
    • /
    • 2005
  • The section of double-tee is considered as one of the most efficient type for flexure. However, the depth of it is bigger then that of other slab systems. The story height of it is also increased because the duct space is required under the double tee in addition to their net depth. Thus, a new modified double-tees with the nib length of 1.58m was suggested in this study. The story height of this one is reduced up to 450mm by including duct space under the nib at the ends of slab. The four ends of the modified two single tees were designed by strut-tie models. Shear tests were performed on them to verify the safety. The ultimate shear strengths of non-prestressed two specimens were larger than the design shear strength by strut-tie models. They were failed in ductile with many distributed flexural crackings. However, the other prestressed two specimens showed much stiffer behaviors, less deflection. and strength than those of prestressed.

  • PDF

Investigation of the shear behaviour of multi-story reinforced concrete walls with eccentric openings

  • Taleb, Rafik;Bechtoula, Hakim;Sakashita, Masanubo;Bourahla, Noureddine;Kono, Susumu
    • Computers and Concrete
    • /
    • 제10권4호
    • /
    • pp.361-377
    • /
    • 2012
  • Four Reinforced Concrete (RC) single span structural walls having various opening sizes and locations were constructed and tested under lateral reversed cyclic loading at the structural laboratory of Kyoto University. These specimens were scaled to 40% and represented the lower three stories of a six-storied RC building. The main purposes of the experimental tests were to evaluate the shear behavior and to identify the influence of opening ratios on the cracks distribution and shear strength of RC structural walls. The shear strength of the specimens was estimated by combining the shear strength of structural wall without openings and the reduction factor that takes into account the openings. Experimental and analytical results showed that the shear strength was different depending on the loading direction due to opening locations. A two-dimensional finite element analysis was carried out to simulate the performance of the tested specimens. The constructed finite elements model simulated the lateral load-drift angle relations quite well.

3차원 비정형 Setback 구조물의 지진 거동 (A Seismic Behavior of a 3-dimensional Irregular Setback Structure)

  • 문성권
    • 한국전산구조공학회논문집
    • /
    • 제13권1호
    • /
    • pp.105-113
    • /
    • 2000
  • 임의의 층에서 평면적에 큰 차이를 보이는 3차원 비정형 setback 구조물의 지진 거동 특성과 지진 거동 특성에 미치는 바닥 슬래브의 면내 변형 효과를 연구하였다. 비정형 setback 구조물의 전반적인 지진 거동 특성을 분석하기 위하여 베이스 부분의 평면적과 타워 부분의 평면적의 비(R/sub s/)와 단(setback) 발생 위치(L/sub s/)등을 매개 변수로 사용하였다. 48개의 비정형 setback 구조물들에 대한 해석 결과로부터 정형 구조물과 달리 setback 구조물의 경우에 단(setback) 발생 위치 근방에서 매우 급격한 층 전단력의 변화가 일어남을 알 수 있었다. 바닥슬래브의 면내 변형이 구조물의 지진 거동에 미치는 영향은 횡방향 저항 요소의 배치에 따라 크게 좌우되며 횡방향 저항 요소들간의 강성의 차이가 심하게 나타나는 전단벽-프레임 시스템의 경우에 더욱 두드러지게 나타남을 알 수 있다. 바닥슬래브의 면내 변형은 구조물이 받게 되는 밑면 전단력을 감소시키며 특히 L/sub s/=0.1인 프레임-전단벽 시스템에서 두드러진다. 또한 바닥슬래브의 면내 변형은 전단벽이 설치된 프레임에 대해서는 층 전단력의 감소 효과를 가져오고 전단벽이 설치되지 않은 프레임에 대해서는 층 전단력의 증가 현상을 가져온다. 또한 횡방향 강성의 차이로 발생한 베이스 부분과 타워 부분에서의 바닥슬래브의 면내 변형으로 인하여 모든 층의 층 변위가 크게 증가됨을 알 수 있다.

  • PDF

Smart System Identification of Super High-Rise Buildings using Limited Vibration Data during the 2011 Tohoku Earthquake

  • Ikeda, A.;Minami, Y.;Fujita, K.;Takewaki, I.
    • 국제초고층학회논문집
    • /
    • 제3권4호
    • /
    • pp.255-271
    • /
    • 2014
  • A method of smart system identification of super high-rise buildings is proposed in which super high-rise buildings are modeled by a shear-bending system. The method is aimed at finding the story shear and bending stiffnesses of a specific story only from the horizontal floor accelerations. The proposed method uses a set of closed-form expressions for the story shear and bending stiffnesses in terms of the limited floor accelerations and utilizes a reduced shear-bending system with the same number of elements as the observation points. A difficulty of prediction of an unstable specific function in a low frequency range can be overcome by introducing an ARX model and discussing its relation with the Taylor series expansion coefficients of a transfer function. It is demonstrated that the shear-bending system can simulate the vibration records with a reasonable accuracy. It is also shown that the vibration records at two super high-rise buildings during the 2011 Tohoku (Japan) earthquake can be simulated with the proposed method including a technique of inserting degrees of freedom between the vibration recording points. Finally it is discussed further that the time-varying identification of fundamental natural period and stiffnesses can be conducted by setting an appropriate duration of evaluation in the batch least-squares method.

건축구조물의 층전단력 분포에 기초한 마찰감쇠기의 최적설계 (Optimal Design of Friction Dampers based on the Story Shear Force Distribution of a Building Structure)

  • 이상현;민경원;박지훈;이루지
    • 한국지진공학회논문집
    • /
    • 제9권6호
    • /
    • pp.21-30
    • /
    • 2005
  • 본 연구에서는 지진하중을 받는 탄성구조물을 대상으로 층전단력 분포에 기초한 마찰감쇠기의 설계방법을 제시하였다. 먼저 마찰감쇠기의 슬립하중(slip-load)을 정규화하는 방법 별로 단자유도 시스템의 수치해석을 수행하고 비교하였다. 이를 통해 슬립하중과 가새 강성의 영향을 파악하였으며, 설치용 가새와 원구조물의 최적강성비를 찾았다. 다음으로는 다양한 고유주기와 층수를 갖는 구조물을 대상으로 수치해석을 통해 마찰감쇠기의 설치 층수와 위치의 결정방법 및 슬립하중의 분배 방법을 도출하였다. 이 과정에서 설치 층수가 포함된 성능지수를 사용하여 슬립하중의 총합으로부터 최적의 설치 층수를 도출하는 경험식을 제시하였다. 마지막으로 실제 지진하중을 사용한 수치해석을 통해 기존의 최적설계 방법과 비교하여 제안된 방법의 우수성을 입증하였다.