• Title/Summary/Keyword: Storm runoff water

Search Result 334, Processing Time 0.039 seconds

Identifying dominant parameters of storm-sewer-overflows in seperate sewer system (강우시 도시배수구역의 유출특성 지배인자 분석)

  • Jung, Si Mon;Park, In Hyeok;Ha, Sung Ryong
    • Journal of Wetlands Research
    • /
    • v.10 no.2
    • /
    • pp.105-114
    • /
    • 2008
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Separated sewer overflows(SSO) have been considered as a major cause of water-quality deterioration of natural water-courses in the vicinity of the heavily urbanized areas. The factors defining the magnitude and occurrence of SSO are site-specific. It is important to know exact properties of pollutants contained in SSO to address water quality impacts that are caused by SSO inputs to the receiving waters. Site and event parameters found to have significant influences on urban runoff pollutant EMCs include total event rainfall, antecedent dry period, rainfall intensity. In this study, a field survey was carried out in some selected areas of Cheongju city. Literature from previous similar studies was consulted and some important factors affecting the runoff characteristics of urban drainage areas were analyzed for some selected survey points. It was found that the factors most affecting BOD are the number of dry days prior to rainfall and the intensity of the rainfall. The factor most affecting CODcr is the number of dry days prior to rainfall. The factors most affecting SS are the amount of rainfall and the number of dry days prior to rainfall. The factor most affecting TN is the amount of rainfall. The factor most affecting TP is the amount of rainfall and the number of dry days prior to rainfall.

  • PDF

A study on changes in water cycle characteristics of university campus catchment: focusing on potential evapotranspiration improvement in Mt. Gwanak catchment (대학 캠퍼스 유역의 물순환 특성 변화에 관한 연구: 관악산 유역 잠재증발산량 개선을 중심으로)

  • Kim, Hyeonju;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1077-1089
    • /
    • 2022
  • With the construction of Seoul National University (SNU), the Mt. Gwanak watershed has undergone some urbanization. As with other campus catchments, data related to the water cycle is extremely limited. Therefore, this study began by collecting hydrological and meteorological data using Atmos-41, a complex meteorological observation instrument. The observation results of Atmos-41 were validated by analyzing the statistical characteristics and confidence intervals based on the monthly variability of data from the Korea Meteorological Administration. Results of the previous research were used to validate the simulated surface runoff and infiltration using the Storm Water Management Model (SWMM). The potential evapotranspiration (PET) simulated by the SWMM was rectified by comparing it to the Atmos-41 observation data. Multiple regression analysis was employed to adjust for the fluctuations in precipitation, relative humidity, and wind speed because the calculated SWMM PET tends to be underestimated during periods of low temperatures. R2 increased from 0.54 to 0.80 when compared to the Atmos-41 PET. The rate of change in the water cycle as a consequence of the SNU's construction resulted in a 15.7% increase in surface runoff, a 14.2% decrease in infiltration rate, and a 1.6% decrease in evaporation.

The optimal parameter estimation of storage function model based on the dynamic effect (동적효과를 고려한 저류함수모형의 최적 매개변수 결정)

  • Kim Jong-Rae;Kim Joo-Cheal;Jeong Dong-Kook;Kim Jae-Han
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.7 s.168
    • /
    • pp.593-603
    • /
    • 2006
  • The basin response to storm is regarded as nonlinearity inherently. In addition, the consistent nonlinearity of hydrologic system response to rainfall has been very tough and cumbersome to be treated analytically. The thing is that such nonlinear models have been avoided because of computational difficulties in identifying the model parameters from recorded data. The parameters of nonlinear system considered as dynamic effects in the conceptual model are optimized as the sum of errors between the observed and computed runoff is minimized. For obtaining the optimal parameters of functions, the historical data for the Bocheong watershed in the Geum river basin were tested by applying the numerical methods, such as quasi-linearization technique, Runge-Kutta procedure, and pattern-search method. The estimated runoff carried through from the storage function with dynamic effects was compared with the one of 1st-order differential equation model expressing just nonlinearity, and also done with Nash model. It was found that the 2nd-order model yields a better prediction of the hydrograph from each storm than the 1st-order model. However, the 2nd-order model was shown to be equivalent to Nash model when it comes to results. As a result, the parameters of nonlinear 2nd-order differential equation model performed from the present study provided not only a considerable physical meaning but also a applicability to Korean watersheds.

The characteristics of discharged non-point pollutants on Hwa-sung lake inflow streams on precipitation (화성호 유입하천의 강우시 비점오염물질 유출특성)

  • Lee, Sang Eun;Choi, I Song;Lee, In Ho;Hong, Dae Byuk;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.651-661
    • /
    • 2011
  • The purpose of this study is to estimate the characteristics and pollutant loadings of non-point pollutants that flowed in the streams on precipitation for pollutant loading reduction of Hwa-sung lake inflow streams. Although it has been made an effort to improve the water quality of Hwa-sung basin through the strategies for the preservation of water quality, it is shown that the water quality is not greatly improved. Because it has been industrialized and urbanized near Hwa-sung basin so that it is difficult to reduce the water pollution due to the increase in pollutant loadings of point and non-point sources. In this study, it is investigated the outflow characteristics of non-point pollutants that discharged with storm runoff and estimated the effect of runoff on Hwa-sung basin. The final goal of this study is to utilize the basic information for proper management and strategies of non-point sources on Hwa-sung basin. At the result of inflow streams, Ja-an stream that has the greatest pollutant loadings on precipitation is strongly influenced on the water quantity of Hwa-sung basin. On the other hand, it is shown that Nam-yang stream is strongly influenced on the SS concentration of Hwasung basin among them. Also, all streams; Nam-yang, Ja-ahn, Ah-eun stream; has the degree of slope more than or near 1 in the correlation results so that they have strong pollutant loading impact and the concentration of SS is the highest among other pollutants. So, specific studies on initial rain phenomena are more necessary to manage the pollutants economically. Also, the proper control of SS concentration is required to manage the effluent pollutants effectively on precipitation. So, it is necessary to consider the strategies for non-point pollutants as well as point pollutants when the new management is imposed to reduce the pollutant load for improvement of Hwa-sung basin.

A study on the determination of location of the detention pond in trunk sewer for reducing runoff amounts (우수유출저감을 위한 간선저류지 위치선정에 관한 연구)

  • Lee, Sung Ho;Yoon, Sei Eui;Lee, Jae Joon
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • The ability to defend against floods in urban areas was weakened, because the increase in the impervious rate of urban areas due to urbanization and industrialization and the increase in the localized torrential rainfall due to abnormal climate. In order to reduce flood damage in urban areas, various runoff reduction facilities such as detention ponds and infiltration facilities were installed. However, in the case of domestic metropolitan cities, it is difficult to secure land for the installation of storm water reduction facilities and secure the budget for improving the aged pipelines. Therefore, it is necessary to design a storage system (called the detention pond in trunk sewer) that linked the existing drainage system to improve the flood control capacity of the urban area and reduce the budget. In this study, to analyze the effect of reducing runoff amounts according to the volume of the detention pond in trunk sewer, three kinds of virtual watershed (longitudinal, middle, concentration shape) were assumed and the detention pond in trunk sewer was installed at an arbitrary location in the watershed. The volume of the detention pond in trunk sewer was set to 6 cases ($1,000m^3$, $3,000m^3$, $5,000m^3$, $10,000m^3$, $20,000m^3$, $30,000m^3$), and the installation location of the detention pond in trunk sewer was varied to 20%, 40%, 60%, and 80% of the detention pond upstream area to the total watershed area (DUAR). Also, using the results of this study, a graph of the relationship and relational equation between the volume of the detention pond in trunk sewer and the installation location is presented.

Application of a Penalty Function to Improve Performance of an Automatic Calibration for a Watershed Runoff Event Simulation Model (홍수유출 모형 자동 보정의 벌칙함수를 이용한 기능 향상 연구)

  • Kang, Taeuk;Lee, Sangho
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1213-1226
    • /
    • 2012
  • Evolutionary algorithms, which are frequently used in an automatic calibration of watershed runoff simulation models, are unconstrained optimization algorithms. An additional method is required to impose constraints on those algorithms. The purpose of the study is to modify the SCE-UA (shuffled complex evolution-University of Arizona) to impose constraints by a penalty function and to improve performance of the automatic calibration module of the SWMM (storm water management model) linked with the SCE-UA. As indicators related to peak flow are important in watershed runoff event simulation, error of peak flow and error of peak flow occurrence time are selected to set up constraints. The automatic calibration module including the constraints was applied to the Milyang Dam Basin and the Guro 1 Pumping Station Basin. The automatic calibration results were compared with the results calibrated by an automatic calibration without the constraints. Error of peak flow and error of peak flow occurrence time were greatly improved and the original objective function value is not highly violated in the automatic calibration including the constraints. The automatic calibration model with constraints was also verified, and the results was excellent. In conclusion, the performance of the automatic calibration module for watershed runoff event simulation was improved by application of the penalty function to impose constraints.

Characteristics of Metal Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량 강우유출수의 중금속 오염물질 특성과 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.385-392
    • /
    • 2005
  • The control of nonpoint source pollution is essentially needed to successfully perform the Total Maximum Daily Load program. Of the various land uses in the nonpoint source, the paved areas such as a parking lot and a bridge are stormwater intensive land uses because of high imperviousness and high pollutant mass emissions. This research was performed to understand the magnitude and nature of the stormwater emissions with the purposes of quantifying stormwater pollutant concentrations and mass emission rates from a parking lot and a bridge. Two monitoring sites in Kongju city were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the data such as rainfall, water quality and runoff flow rates. This paper will summarize the metal concentration changes during the storm duration and metal EMCs to characterize the concentration profiles in a parking lot and a bridge. Also a new concept, dynamic EMC, will be proposed to find the relationship between EMC and first flush effect. It can be used to determine the economical treatment criteria in best management practices.

Development of the hi-speed composite cohesive device for reduction of particulate pollutants in storm water runoff (초기강우 유출수의 입자성 오염물질 처리를 위한 고속복합응집장치 개발)

  • Choi, Sunhwa;Lee, Jinkyung;Lee, Seungheon;Kim, Heungseop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.197-197
    • /
    • 2017
  • 본 연구에서는 입자성 오염물질을 다량 함유하고 있는 초기강우 유출수를 처리하기 위한 수처리 시설로 고속복합응집장치를 개발하였다. 고속응집복합장치의 요소기술은 마이크로 버블, 급속교반장치(인라인믹서), 전기촉매를 이용한 부상촉진장치, 볼텍스 흐름 등으로 구성되며, 기술 원리는 응집제에 의해 오염물질을 응결, 응집, 부상시켜 스컴을 제거하는 일반 응집 원리와 유사하다. 본 기술의 특징은 교반, 혼화조, 응집제를 1개의 조에 컴팩트하게 구성하여 체류시간을 10분 이내로 단축하였고, 볼텍스(voltex) 흐름을 이용한 선회류와 루버홀 형태의 스크린을 적용하여 응집효과를 극대화하였으며, 플럭에 의한 막힘이 없이 스크리닝이 이루어질 수 있도록 하였다. 또한, 부상촉진장치(전기유도)를 이용해 응집 플럭의 부상효과를 상승시켰고, 감속기와 일체화된 내통스크린이 선회류와 반대 방향으로 회전하면서 볼텍스 흐름의 가속효과에 의한 스크린 폐색 방지 및 응집부상 효율을 향상시킬 수 있도록 설계하였다. 부상슬러지는 별도의 플럭 제거 설비 없이 스크린 내통 회전에 이용되는 감속기에 부착된 스컴 제거기에 의해 동시 제거가 가능하며, 응집부상 처리수는 장치 가장 바깥 외곽에 충진된 필터층에서 최종 여과되어 방류되도록 구성함으로서 모든 처리공정이 단일 장치 내에서 이루어지도록 구성하였다. 본 고속복합응집장치는 전체 규격 ¢ $1000{\times}2,000mmH$의 시제품이 제작되어 현재 시흥소재 매화저수지에서 성능평가를 실시하고 있다.

  • PDF

A Study on Optimal Flood Runoff Model for Urban Flood Forecasting (도시홍수예보를 위한 최적의 홍수유출모형에 대한 연구)

  • Yuk, Gi Moon;Chun, Soo Bin;Kim, Min Seok;Moon, Young Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.379-379
    • /
    • 2017
  • 과거에는 하천 범람으로 인한 홍수피해가 많았으나 최근에는 도시화로 인한 불투수면적의 증가로 홍수도달시간의 단축 및 노면수의 배수불량으로 인한 내수 홍수피해가 많아졌다. 이러한 변화는 도시하천의 홍수예보에 밀접한 관련이 있으며 관련된 분석 모형 및 연계방안 또한 매우 중요하게 되었다. 일반적으로 하천에 대한 유출해석 모형으로 HEC-RAS((Hydrologic Engineering Center-River Analysis System)가 주로 사용되고 있으나 현재와 같이 도심지 하천에서는 내배수의 특성을 고려한 SWMM(Storm Water Management Model)을 사용한다. 또는 이 두모형의 연계를 통해 유출해석을 진행하기도 한다. 최근 HEC-RAS와 SWMM모형이 최신 버전을 공개하였다. HEC-RAS의 경우 2016년 9월 5.0.3버전을 출시하며 1D뿐만 아닌 2D의 모의도 가능하도록 기능을 개선하였으며 SWMM의 경우 2016년 09월 07일 5.1.011버젼이 공개되었다. 본 연구에서는 공개된 최신 모형을 도림천 지역에 적용하여 도림천 지역에 적합한 모형 및 연계 방법을 찾아보려 한다. 이를 통해 최적의 도시홍수예보 시스템을 구성하기 위한 모형 및 연계방안의 조사와 가장 합리적인 도시홍수 시스템의 구성방안을 제시하고자 한다.

  • PDF

A study of predicting runoff volume applying a two-parameter analytical probabilistic model for South Korea (이변수 해석적 확률모형을 적용한 우리나라 유출량 예측 연구)

  • Lee, Moonyoung;An, Heejin;Jeon, Seol;Kim, Si Yeon;Min, inkyung;Park, Daeryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.201-201
    • /
    • 2022
  • 본 연구에서는 강우량이 여름에 집중되어있는 우리나라의 강우 특성을 잘 나타낼 수 있는 최적의 확률분포형을 선정하고 해석적 확률모델 (Analytical Probabilistic Model, APM)을 개발하여 유출량을 예측하고자 하였다. 국내 10개 지역인 부산, 춘천, 대구, 대전, 전주, 진주, 서울, 속초, 태백, 원주를 연구 지역으로 설정하였고, 30년 시 단위 강우자료를 지역별 interevent time definition(IETD)을 적용하여 강우 사상으로 그룹화하였다. APM 연구에 일반적으로 사용되는 일변수 지수 분포 이외의 이변수 지수, 감마, 이변수 로그정규 확률밀도함수 (Probability Density Function, PDF)를 강우사상의 특성인 강우량, 강우 지속시간, 무강우 시간의 히스토그램에 적용한 결과, 이 변수 로그정규분포가 우리나라의 강우 특성을 가장 잘 대표하였다. 로그정규분포를 이용하여 APM을 유도하고 유출량을 예측하였다. 예측한 유출량에 대한 빈도분석을 수행하여 Storm Water Management Model (SWMM)의 결과와 비교함으로써 유도한 APM의 적합성을 확인하였다. SWMM의 입력 매개변수 보정을 위해서는 서울 군자 지역에서 관측한 실제 강우량 및 유출량 자료를 사용하였다. 로그정규분포로 유도한 APM과 SWMM의 빈도분석 결과를 비교하였을 때 초과 확률과 재현주기 모두 매우 유사한 결과를 나타내었음을 확인하였다.

  • PDF