• Title/Summary/Keyword: Storage facilities

Search Result 808, Processing Time 0.024 seconds

Appropriateness Assessment of Dike Height of a Chemical Plant through Development of a Hazardous Chemical Leakage Trajectory Evaluation Module (유해화학물질 누출궤적 평가모듈 개발을 통한 화학공장 방류벽 높이의 적정성 평가)

  • Yoo, Byungtae;Kim, Hyeonggi
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.121-129
    • /
    • 2019
  • The Chemical Control Act of 2015 was enhanced to ensure the safe management of hazardous chemicals. In particular, there have been substantial changes in the standards for the installation and management of handling facilities for manufacturing and storing hazardous chemicals. However, some standards for handling facilities are difficult to implement due to a lack of physical space or because of safety accidents during facility improvements. Therefore, the Safety assessment system (SAS) has been operating for such facilities since 2018. This study developed a leakage trajectory evaluation module that can easily evaluate the outside of a dike for safety evaluation. We analyzed two case studies on a dike for hydrochloric acid and sulfuric acid storage tanks with this module and suggest a reasonable plan for the facility. We believe that it will be possible to more easily submit SAS reports at chemical plants by using this evaluation module. This study is expected to contribute to the improvement of the safety design of hazardous chemical handling facilities.

Development and Its Application of a Discrete Fracture Flow Model for the Analysis of Gas-Water Transient Flow in Fractured Rock Masses Around Storage Cavern (지하저장공동 주변 불연속 암반에서의 가스-물 천이유동해석을 위한 개별균열 유동모델의 개발 및 응용)

  • 나승훈;성원모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.705-712
    • /
    • 2000
  • The fluid generally flows through fractures in crystalline rocks where most of underground storage facilities are constructed because of their low hydraulic conductivities. The fractured rock is better to be conceptualized with a discrete fracture concept, rather continuum approach. In the aspect of fluid flow in underground, the simultaneous flow of groundwater and gas should be considered in the cases of generation and leakage of gas in nuclear waste disposal facilities, air sparging process and soil vapor extraction for eliminating contaminants in soil or rock pore, and pneumatic fracturing for the improvement of permeability of rock mass. For the purpose of appropriate analysis of groundwater-gas flow, this study presents an unsteady-state multi-phase FEM fracture network simulator. Numerical simulation has been also conducted to investigate the hydraulic head distribution and air tightness around Ulsan LPG storage cavern. The recorded hydraulic head at the observation well Y was -5 to -10 m. From the results obtained by the developed model, it shows that the discrete fracture model yielded hydraulic head of -10 m, whereas great discrepancy with the field data was observed in the case of equivalent continuum modeling. The air tightness of individual fractures around cavern was examined according to two different operating pressures and as a result, only several numbers of fractures neighboring the cavern did not satisfy the criteria of air tightness at 882 kPa of cavern pressure. In the meantime, when operating pressure is 710.5 kPa, the most areas did not satisfy air tightness criteria. Finally, in the case of gas leaking from cavern to the surrounding rocks, the resulted hydraulic head and flowing pattern was changed and, therefore, gas was leaked out from the cavern ceiling and groundwater was flowed into the cavern through the walls.

  • PDF

Evaluation of Neutron Flux Accounting for Shadowing Effect Among the Dry Storage Casks (경수로 사용후핵연료 건식저장용기 간 중성자 표면선속 간섭률 평가)

  • Min Woo Kwak;Shin Dong Lee;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.133-140
    • /
    • 2024
  • The Korean 2nd basic plan for management of high-level radioactive waste presented a plan to manage spent nuclear fuel through dry storage facilities in NPP on-site. For the construction and operation of the facility, it is necessary to develop the monitoring system of the integrity of spent nuclear fuel before operation. NUREG-1536 recommends that the theoretical cask array, typically in the 2×10 array, should account for shadowing effect among the dry storage casks. The objective of this study was to evaluate neutron flux accounting for shadowing effect among dry storage casks. The neutron release rate was evaluated using ORIGEN based on the design basis fuel condition. And the simulation of dry storage casks and evaluation of the shadowing effect were performed using MCNP. Shadowing effect of other dry storage casks was the highest at the center of the dry storage facility of the 2×10 array compared with the outside of the cask. The shadowing effect of neutron flux on the surface among the metal casks was approximately 18% at point 1, 23% at point 2, and 43% at point 3. For the concrete casks, the shadowing effect of neutron flux on the surface was approximately 46% at point 1, 51% at point 2, and 52% at point 3. This means that correction is necessary to monitor the integrity of spent nuclear fuel in each dry storage cask through evaluation of shadowing effect. The results of this study will be used for comparative analysis of neutron measurement data from spent nuclear fuels in dry storage cask. Additionally, the neutron flux evaluation procedure used in this study could be used as the basic data of safety assessment of dry storage cask and development of safety guide.

An Analysis of Unit Care Characteristics of Large Skilled Nursing Facilities for the Elderly in City Areas (도심지역 대규모 노인전문요양시설의 단위공간별 특성 분석)

  • Lee, Min-Ah
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.49-52
    • /
    • 2007
  • The purpose of this study was to investigate unit care characteristics of large skilled nursing facilities for the elderly, which are located in city areas, and to discuss the way of encouraging home-like atmosphere in perspective of spatial unit. First of all, the analysis of five facilities opened before 2002 was performed, based on previous studies, to compare with them opened in recent 5 years. Most of the previous facilities did not have differentiation between their residential and nursing units, and the number of residents in each unit were excessive in comparison with the standard limit(12-28). On the contrary, the facilities established in recent 5 years had systematic spatial unit structure. The residential units had basically rooms and spaces for small group and the number of elderly residents per unit was appropriate on the basis of standard limit which was suggested by Kwon(2002). The nursing units were consist of nursing station, 2-3 residential units, spaces for large group of residents, hair dressing, nurse, living assistant, bathing, storage and etc. But, there was a problem In space usage even though they have distinct unit care systems. Some spaces for groups were empty without residents, furniture, and other equipments, which were necessary for unit care.

  • PDF

On the Analysis of Physical Distribution System in Inchon Port (인천항의 물류시스템에 관한 연구)

  • 황해성;곽규석
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.1
    • /
    • pp.13-31
    • /
    • 1997
  • Being situated at the key point of northeast asia, the port of Inchon as an entrance to the captial city, Seoul is expected to play in marine transportation in Korean Pennisular on the verge of its reunification. In this thesis, inner-lock physical disstribution system of the port was analyzed, which treats more than 82% of total incoming and outgoing cargoes. The overall findings are as follows; 1. In thet viewpoint of physical distribution system of the port, it takes disadvantages of accessing to inner lock berth due to such natural restrictions as tides, passing the lock and so on. And insufficient port facilities as a whole, causes delay in quay-handling, transfer and storage, also facing with serious congestion in inland transport on the road. 2. It was revealed that the port facilities are insufficient yet in spite of its improved productivity by means of raising the effectiveness of port operation and of installing advanced cargo handling facilities. 3. In order to enhance the effectiveness of inner port physical distribution system , the improvement of lock facilities, expansionof port facilities and more effective terminal operating system are crucial. 4. To ensure the measures to solve the above problem, existent outer-lock ports such as Inchon Sourthern-port and Northern-port are necessary to be redeveloped more positively , otherwise a new port at outskirt of the city should be developed to ensure free connection to inland transportation.

  • PDF

Vulnerability assessment of upland public groundwater wells against climate change

  • Shin, Hyung Jin;Lee, Jae Young;Jo, Sung Mun;Cha, Sang Sun;Park, Chan Gi
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.577-596
    • /
    • 2020
  • Drought is a natural disaster that directly affects agriculture, which has a great impact on the global agricultural production system and yield. The lack of water storage in most parts of the country due to the lack of precipitation has caused a great increase in social interest in drought due to the dryness of rice fields and crops. As the drought period increases and the drought intensity becomes stronger, it is believed that drought damage to crops will continue; thus, it is necessary to understand the vulnerability to irrigation performance and the ability of irrigation facilities. Therefore, this study conducted a vulnerability assessment of irrigation facilities (public Groundwater well) in cities across the country. The survey was conducted using statistical data from 2007 to 2016, and the vulnerability score was calculated according to the vulnerability evaluation procedure for drought in the irrigation facilities (public groundwater wells). Among 157 regions, 136 areas were very vulnerable; 14 areas were vulnerable; 3 areas were normal; 4 areas were good, and 0 areas were excellent. The vulnerability assessment can be used as basic data for the development or maintenance of field irrigation facilities in the future by understanding the vulnerability of irrigation facilities.

Optimal Design of Batch-Storage Network with Finite Intermediate Storage (저장조 용량제약이 있는 회분식 공정-저장조 그물망 구조의 최적설계)

  • Kim, Hyung-Min;Kim, Kyoo-Nyun;Lee, Gyeong-Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.867-873
    • /
    • 2001
  • The purpose of this study is to find analytic solution of determining the optimal capacity (lot-size) of multiproduct acyclic multistage production and inventory system to meet the finished product demand under the constraint of finite intermediate storage. Intermediate storage is a practical way to mitigate the material flow imbalance through the line of supply and demand chain. However, the cost of constructing and operating storage facilities is becoming substantial because of increasing land value, environmental and safety concern. Therefore, reasonable decision-making about the capacity of processes and storage units is an important subject for industries. The industrial solution for this subject is to use the classical economic lot sizing method, EOQ/EPQ(Economic Order Quantity/Economic Production Quantity) model, incorporated with practical experience. But EOQ/EPQ model is not suitable for the chemical plant design with highly interlinked processes and storage units because it is developed based on single product and single stage. This study overcomes the limitation of the classical lot sizing method. The superstructure of the plant consists of the network of serially and/or parallelly interlinked non-continuous processes and storage units. The processes transform a set of feedstock materials into another set of products with constant conversion factors. A novel production and inventory analysis method, PSW(Periodic Square Wave) model, is applied to describe the detail material flows among equipments. The objective function of this study is minimizing the total cost composed of setup and inventory holding cost. The advantage of PSW model comes from the fact that the model provides a set of simple analytic solutions in spite of realistic description of the material flows between processes and storage units. the resulting simple analytic solution can greatly enhance the proper and quick investment decision for the preliminary plant design problem confronted with economic situation.

  • PDF

A study on the work in fishing convention, 2007 and the fishing vessel's accommodation facilities standards in national fishing vessel act (ILO어선원노동협약과 어선법의 어선거주설비에 대한 고찰)

  • Kim, Wook-Sung;Park, Moon-Gap
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.466-475
    • /
    • 2010
  • This study intends to present a direction for the better reforming of fishers'onboard living conditions and proposals for preparing for ratification of the Work in Fishing Convention by means of making a comparison between standards on recent national fishing vessel accommodation facilities and standards on the Work in Fishing Convention and Its Recommendation, 2007, ILO. For the most part of standards on national fishing vessel accommodation facilities are somewhat insufficient to satisfy the provisions in Annex III of the Convention. Considering by items on fishing vessel accommodation facilities, the standards on insect protector, noise and vibration, heating and air conditioning, lighting, persons per sleeping room, recreational facility are not provided in national law. Headroom, separation of accommodation, sleeping room floor area, mattress size, mess room, galley and food storage are partially sufficient for the Convention. In case of sanitary facilities, national standards are not sufficient for the Convention. The other side, facilities related safety of ship and crew such as emergency escape etc., are fully sufficient for the Convention. These insufficiencies caused by different types of fishing vessel depend on originality of fishing method and practices. In the comparison between equivalent tonnage about vessel's length on convention and calculated tonnage of national existing fishing vessel, the difference are 226tons about length 24m and 501tons about length 45m. For that reason, headroom, persons per sleeping room, cabin of sicker and injured, sanitary facilities may decide to use gross tonnage in place of length (L) and the alleviating measure basis of convention. But in case of standards on sanitary facilities which are unsufficient for the Convention, specially in coastal fishing vessel length basis should be adopted with alleviating basis for less than length 24m.

A Study on the vulnerability of the agricultural infrastructure based on the product of garlic and onions - Focused on Jeolla-do and Gyeongsang-do - (마늘 및 양파 주산지 농업생산기반시설의 취약성 분석 - 전라도, 경상도를 중심으로 -)

  • Jung, hyunwoo;Paik, sinwon;Kim, hanjoong
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.143-152
    • /
    • 2017
  • In recent years, the proportion of arable land in the nation has grown from 36.2 percent in 1990 to 43.7 percent in 2013. The study first performed the vulnerability assessment of agricultural production, transportation, processing facilities, agricultural machinery leasing facilities, and water supply facilities. It was developed for the evaluation of the vulnerability of each gun of garlic and onions based on the distance from the three groups of arable bodies to the facility and the processing capacity of facilities. In view of these regional imbalances, the store, distribution and processing facilities in the main stream were found in Haenam, South Jeolla-do, and the relatively low regions of the gun were located in Goheung-gun and Hampyeong-gun. Among other regions, agricultural machinery rental facilities were high in Changnyeong-gun, Haenam, and two regions, while the water supply facilities were high in the southern area of Haenam and South Jeolla-do. The Gyeongsang-do showed relatively high levels of comparison vulnerability index compared to Jeolla-do regions. In particular, through the management plan to improve the facilities needed to improve agricultural production infrastructure, it is necessary to increase the competitiveness of agricultural productuivity through the planning of the need for additional support through the rural readjustment project.

Hydrological Evaluation of Rainwater Harvesting: 1. Hydrological Analysis (빗물이용의 수문학적 평가: 1. 수문해석)

  • Yoo, Chulsang;Kim, Kyoungjun;Yun, Zuhwan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.221-229
    • /
    • 2008
  • This study revised a model for hydrologically analyzing rainwater harvesting facilities considering their rainfall-runoff properties and the data available. This model has only a few parameters, which can be estimated with rather poor measurements available. The model has a non-linear module for rainfall loss, and the remaining rainfall excess (effective rainfall) is assumed to be inflow to the storage tank. This model has been applied for the rainwater harvesting facilities in Seoul National University, Korea Institute of Construction Technology, and the Daejon World Cup Stadium. As a result, the runoff coefficients estimated were about 0.9 for the building roof as a rainwater collecting surface and about 0.18 for the playground. This result is coincident with that for designing the rainwater harvesting facilities to show the accuracy of model and the simulation results.