• Title/Summary/Keyword: Storage depth

Search Result 389, Processing Time 0.022 seconds

Soil Carbon Cycling and Soil CO2 Efflux in a Red Pine (Pinus densiflora) Stand

  • Kim, Choon-Sig
    • Journal of Ecology and Environment
    • /
    • v.29 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • This study was conducted to evaluate forest carbon cycling and soil $CO_2$ efflux rates in a 42-year-old pine (Pinus densiflora) stand located in Hamyang-gun, Korea. Aboveground and soil organic carbon storage, litterfall, litter decomposition, and soil $CO_2$ efflux rates were measured for one year. Estimated aboveground biomass carbon storage and increment in this stand were $3,250gC/m^2\;and\;156gC\;m^{-2}yr^{-1}$, respectively. Soil organic carbon storage at the depth of 30 cm was $10,260gC/m^2$ Mean organic carbon inputs by needle and total litterfall were $176gC\;m^{-2}yr^{-1}\;and\;235gC\;m^{-2}yr^{-1}$, respectively. Litter decomposition rates were faster in nne roots less than 2 mm diameter size ($<220\;g\;kg^{-1}yr^{-1}$) than in needle litter ($<120\;g\;kg^{-1}yr^{-1}$). Annual mean and total soil respiration rates were $0.37g\;CO_2m^{-2}h^{-1}$ and $2,732g\;CO_2m^{-2}yr^{-1}$ during the study period. A strong positive relationship existed between soil $CO_2$ efflux and soil temperature (r=0.8149), while soil $CO_2$ efflux responded negatively to soil pH (r=-0.3582).

Feasibility study on realization of high resolution solid immersion lensbased near-field microscopy by use of an annular aperture (광학 필터를 사용한 고해상 고체침지 렌즈 기반 근접장 현미경 적용 가능성에 대한 연구)

  • Moon, H.B.;Yoon, Y.J.;Kim, T.S.;Park, Y.P.;Park, N.C.;Park, K.S.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.2
    • /
    • pp.79-82
    • /
    • 2010
  • In optical imaging systems, such as microscopes, high resolution exposure systems, and optical storage devices, higher optical resolution is a requirement. One of the promising technologies that is able to satisfy this requirement with relatively simple construction and reliable performance are, solid immersion lens (SIL)-based near-field (NF) optical systems. High NA optical systems using annular apertures have been investigated as one solution to achieve higher resolutions and an extended focal depth. By applying an optimized annular aperture to convention SIL optical head resolution can be increased by approximately 20%. This novel SIL-based near-field optics will be verified through experiments such as measuring focused beam spot profiles and observing the topology of a measurement sample. The studied SIL-based near-field optics can be applicable to not only next generation optical storage device but also high resolution microscopy and pattering technologies.

Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank (관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰)

  • Park, Kyoohong;Yu, Soonyu;Lee, Taehoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is $0.062m^2$(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.

A Study on the Corrosion Fatigue Crack Behavior of SPV 50 for Gas Storage Tanks in Marine Environment (해양환경 중에서 가스저장탱크용 SPV 50강재의 부식피로균열(腐蝕疲勞龜裂) 거동(擧動)에 관한 연구(硏究))

  • Lim, Uh-Joh;Shin, Jong-Dae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.9 no.2
    • /
    • pp.198-208
    • /
    • 1997
  • Recently, with rapid increase of gas demand, there occurs much interest their security of safety in the gas storage tanks and pressure vessels etc. In order to solve the problems, the occurrence of corrosion fatigue crack and the propagation behavior must be investigated. Especially the occurrence of corrosion fatigue crack and the propagation behavior in the part which has concentrated stress or defects, must be studied more carefully. In this paper, the high-tensile steel of SPV 50 which is much used for building the LPG storage tanks was tested by the use of a plane bending corrosion fatigue tester under the various marine environment and in the air. These experiments were carried out to investigate the surface crack propagation behavior, the value of experimental constant for Paris' rule(da/dN=$C(K)^m$), the crack depth propagation rate and the accelerative factor of the surface crack propagation rate. The main results obtained are as follows ; 1) As the specific resistances of marine environment decreases, the exponential value of slope m of Paris' rule(da/dN=$C(K)^m$) decreases and the value of intercept C increases. 2) The surface crack propagation rate and the crack depth propagation rate are delayed, as the specific resistances of marine environment is increased. 3) The accelerative factor of the surface crack propagation rate by corrosion fatigue is higher, according as the stress intensity factor range ${\Delta}K_A$ is small.

  • PDF

A Study on the Border Signal-fire In Eastern Sea (조선시대 동해안지역 연변봉수에 관한 연구)

  • Lee, Chul-Young;Kim, Seong-Chul
    • Journal of architectural history
    • /
    • v.17 no.2
    • /
    • pp.47-66
    • /
    • 2008
  • This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, half-circle, oval, round-rectangular. The majorities were circle type in eastern area. 2. Plan configuration of signal-fire stand which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of signal-fire stand was about $2{\sim}3m$. The diameter of signal-fire stand was $8{\sim}10m$. Building base that protect ground moisture and infilteration of rainfall was found in 9 border singal-fire, the height of it was about $0.3m{\sim}2.5m$. 3. Trench was mainly circle type and average width was $3{\sim}4m$. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 4. The height of protective wall remained until present was about 1m, the depth was about average 2.5m. 5. The storage of border signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the signal-fire stand.

  • PDF

Analysis of First Flush of Recreation Park and Removal Rate According to Rainfall-Runoff Storage Depth (위락시설지역의 초기세척현상과 초기 강우-유출고 저류에 따른 저감효율 분석)

  • Jung, Jae-Woon;Park, Ha-Na;Choi, Dong-Ho;Baek, Sang-Soo;Yoon, Kwang-Sik;Baek, Won-Jin;Beam, Jin-A;Lim, Byung-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.648-655
    • /
    • 2013
  • Nonpoint source pollution characteristics of recreation park was investigated. Runoff ratio of recreation park ranged 23-57%, which was lower than other urban area since impervious area was less than 37%. The average BOD, COD, TOC, SS, T-N, T-P, were 14.09, 32.86, 12.19, 121.51, 7.78 and 0.72 mg/L, respectively. First flush of recreation park was analyzed by normalized cumulative load - volume curve and mass first flush ratio(MFFn), MFF10 for BOD, COD, SS, T-P, T-N, TOC were 2.90, 1.59, 2.15, 2.74, 2.60, and 1.59, respectively. Observed data showed that 62% of pollutant could be removed by storaging 5 mm rainfall-runoff and even 3 mm depth could store up to 50% of pollutant in runoff.

Effect of Long Term Fertilization on Soil Carbon and Nitrogen Pools in Paddy Soil

  • Lee, Chang Hoon;Jung, Ki Youl;Kang, Seong Soo;Kim, Myung Sook;Kim, Yoo Hak;Kim, Pil Joo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.3
    • /
    • pp.216-222
    • /
    • 2013
  • Fertilizer management has the potential to promote the storage of carbon and nitrogen in agricultural soils and thus may contribute to crop sustainability and mitigation of global warming. In this study, the effects of fertilizer practices [no fertilizer (Control), chemical fertilizer (NPK), Compost, and chemical fertilizer plus compost] on soil total carbon (TC) and total nitrogen (TN) contents in inner soil profiles of paddy soil at 0-60 cm depth were examined by using long-term field experimental site at $42^{nd}$ years after installation. TC and TN concentrations of the treatments which included N input (NPK, Compost, NPK+Compost) in plow layer (0-15 cm) ranged from 19.0 to 26.4 g $kg^{-1}$ and 2.15 to 2.53 g $kg^{-1}$, respectively. Compared with control treatment, SOC (soil organic C) and TN concentrations were increased by 24.1 and 31.0%, 57.6 and 49.7%, and 72.2 and 54.5% for NPK, Compost, and NPK+Compost, respectively. However, long term fertilization significantly influenced TC concentration and pools to 30 cm depth. TC and TN pools for NPK, Compost, NPK+Compost in 0-30 cm depth ranged from 44.8 to 56.8 Mg $ha^{-1}$ and 5.78 to 6.49 Mg $ha^{-1}$, respectively. TC and TN pools were greater by 10.5 and 21.4%, 30.3 and 29.6%, and 39.9 and 36.3% in N input treatments (NPK, Compost, NPK+Compost) than in control treatment. These resulted from the formation and stability of aggregate in paddy soil with continuous mono rice cultivation. Therefore, fertilization practice could contribute to the storage of C and N in paddy soil, especially, organic amendments with chemical fertilizers may be alternative practices to sequester carbon and nitrogen in agricultural soil.

Analysis on the Charging Process of Stratified Thermal Storage - Tanks with Variable Inlet Temperature (입구온도가 변화하는 성층축열조의 충전과정 해석)

  • Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.25-37
    • /
    • 1995
  • This paper presents an approximate analytical solution to one-dimensional model of the charging process for stratified thermal storage tanks, in which variation of the inlet temperature as well as the momemtum-induced mixing is taken into accout. The mixing is incorporated into the model as a constant-depth perfectly mixed layer above the plug flow region. Based on the superposition principle, the variable inlet temperature is approximated by a number of step functions. Temperature distributions for the thermocline corresponding to three types of interfacial condition arr successfully derived in terms of well-defined functions, so that a linear combination of them constitutes the final solution. Validity and utility of this work is examined through the comparison of the approximate solution with an exact solution available for the case of linearly increasing inlet temperature. With increasing the number of steps, the present solution asymptotically approaches to the exact one. Even with a limited number of steps, the present results favorably agree with those by the exact solution for a wide range of the mixing depth. Also, it is revealed that fewer steps are needed for meaningful predictions as the mixing. depth becomes larger.

  • PDF

Elements and Actual Condition of Apartment Unit Remodeling - By In-depth Interviews on Residents and Specialists of Interior Design Companies - (아파트 단위주거의 리모델링 요소와 현황 - 인테리어디자인업체 실무자와 거주자 심층면접을 통하여 -)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.57-67
    • /
    • 2007
  • The purpose of this study was to grasp major elements and actual condition of apartment unit remodeling by in-depth interviews on residents and specialists. The interviews had been conducted to interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment unit. In-depth interview is a kind of qualitative method in which attention to reply of responses with open-access between interviewer and respondents. According to the results, remodeling elements were generally changing of lighting fixtures and finishing materials in the all spaces, integration of balcony into children's room, installation of furniture in kitchen and entrance, changing storage furnitures and equipments in bathroom. Artificial lighting method were selected generally whole lighting. Finishing materials were used ordinary (non environmentally-friendly) wallpaper and adhesion and tempered floor. There were unsatisfied factors after remodeling, these were dissatisfaction of design, construction defects, and stink of reflecting 'sick house'. Also they responded that they should be considering to use environmentally-friendly material at next remodeling.

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF