• 제목/요약/키워드: Storage condition

검색결과 1,756건 처리시간 0.034초

NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영 (Parallel reservoirs system operation using NYC-Space Allocation-Rule)

  • 박기범;이순탁
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

수삼의 저장조건에 따른 홍삼의 이화학적 특성 (Physicochemical Properties of Red Ginseng on Storage Condition of the Fresh Ginseng)

  • 김천석;정인찬;김세봉;양덕춘
    • 한국약용작물학회지
    • /
    • 제13권1호
    • /
    • pp.52-56
    • /
    • 2005
  • 본 연구는 수삼의 저장기간 (무저장, 2일, 6일, 8일, 10일) 및 저장온도 $(20^{\circ}C,\;34^{\circ}C,\;-10^{\circ}C)$로 구분하여 제조된 홍삼의 품질 및 이화학적 특성변화를 비교 조사하였다. 수삼의 수분함량은 저장일이 길어질수록 감소하는 경향이었다. 수삼을 10일동안의 단기간 저장온도는 $34^{\circ}C$의 냉장저장이 적합하다고 생각한다. 전질소 함량은 저장일 10일로 갈수록 무저장구에 비해 다소 증가하는 경향이었다. 저장온도별로는 실온, 냉동, 냉장저장 순으로 무저장구보다 전질소 함량이 증가함을 보였다. 각각의 저장구별 페놀성 화합물의 함량은 무저장구에 비하여 저장기간이 길수록 증가하는 경향이었다. 저장 온도별로는 냉장 저장구가 실온, 냉동 저장구에 비하여 다소 페놀성 화합물의 함량이 높았다. 저장조건별 홍삼의 사포닌 Rf 에 대한 8종의 $ginsenoside\;Rb_1,\;Rb_2,\;Rc,\;Rd,\;Re,\;$Rg_3,\;Rg_1,\;Rg_2$의 상대적 함량 (%)비 변화를 분석한 결과, 각각 저장조건에서 Rf 대한 $Rb_1,\;Rg_1$의 상대적 함량비가 저장기간이 늘어날수록 감소하는 경향이었다. 기타 ginsenoside 함량변화는 시료간의 차이에서 나타난 것으로 판단되며 저장조건에 따른 변화 경향은 뚜렷하지 않았다. 관능적 성질에서 각각 저장구별로 홍삼의 품질, 맛과 향을 종합적으로 평가하여 볼 때, $34^{\circ}C$에서 냉장저장 운반하는 것이 홍삼 향미의 안정적 유지에 가장 적합한 것으로 평가되었다.

빙축열 에어컨의 동적 사이클 해석 (Dynamic Analysis of Cool Thermal Storage Air Conditioning System)

  • 고재윤;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, dynamic characteristics analysis of AC system is investigated using a cool thermal storage system. A analysing program for cool thermal storage AC system is developed. The performances are studied by several variables and dynamic characteristics. Comparing the result at conventional operation condition with that at the condition using ice storage system, this study showed the effects of the sub cooled degree, superheated degree, efficiency of compressor and evaporating temperature. At the condition using thermal storage system, the thermal storage process was operated during midnight being not needed the cooling of the AC unit through the continuous running of the condenser. The refrigerant was sub-cooled using stored energy after being discharged from the air source condenser during the daytime. The COP was increased owing to the sub-cooling of refrigerant during daytime, thus the power consumption was effectively decreased.

LNG 외조 저장탱크의 구조적 특성을 고려한 상태평가 기준 개발 (A Development of Condition Evaluation Standard Considering Structural Characteristic for Members of LNG Outer Storage Tanks)

  • 최경재;서창주;김영구;조영도;김정훈
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.64-69
    • /
    • 2017
  • 한국은 세계 2위의 LNG 수입국이고 2017년 기준 약 70기의 LNG 저장탱크가 상업운전 중에 있다. LNG산업의 핵심설비인 LNG 저장탱크는 1986년 상업운전 이후 설계보증 연한인 30년이 경과 되면서 도시가스사업법 개정을 통해 2014년부터 정밀안전진단을 수행하고 있다. 정밀안전진단 시 LNG 저장탱크의 외조 콘크리트에 대해서 상태평가를 할 수 있는 기준이 부재한 상태이다. LNG 저장탱크의 구조적 특성과 기존 토목구조물 상태평가 기준 분석을 통해 저장탱크의 대표부재에 대한 상태평가기준을 개발하였다. 개발된 객관적 상태평가기준은 LNG 저장탱크의 안전성 및 신뢰성을 향상시키고 보수기준을 제시할 수 있다.

건조 및 저장조건에 따른 쌀 저장단백질의 변화양상 (Changes of Rice Storage Proteins Affected by Dry and Storage Temperature)

  • 신평균;장안철;홍성창;이기상;이금희;이용복
    • 한국환경농학회지
    • /
    • 제27권4호
    • /
    • pp.456-459
    • /
    • 2008
  • Quality of rice grain changes during dry storage with internal physiological changes and external injury by organism. Storage rice changes by condition with respiration via variable temperature, hydrolysis enzyme reaction, lipid peroxidation occurs with change of palatability. During dry storage, physiological change with protein variation pattern was examined by image analysis on proteomic technology. Analysis revealed that protein activity had no change store at room temperature and store at $40^{\circ}C$, but decreased store at $60^{\circ}C$. Analysis of variable hydrophobic protein pattern revealed that protein activity of beta-tubulin, protein disulfide isomerase, vacuolar ATPase b subunit, globulin was not significantly decreased all dry and store condition. However, heat shock protein 70, and glutathione transferase was significantly decreased when rice dried at $60^{\circ}C$ compared with room temperature and $40^{\circ}C$ dry condition.

저장 및 저장후 유통조건에 따른 마늘(Allium sativum L.)의 생리적 특성 변화 (Changes in Physiologcal Properties of Garlic (Allium sativum L.) by Storage and Marketing Condition after Storage)

  • 최선태;장규섭
    • 한국식품저장유통학회지
    • /
    • 제5권2호
    • /
    • pp.105-110
    • /
    • 1998
  • To find out suitable storage and marketing condition, northern type 'seosan' garlic was stored for 3 months at controlled atmosphere(CA), modified atmosphere(MA), low(0~1$^{\circ}C$) and room temperature(20$\pm$5$^{\circ}C$), and then marketed at low(2~3$^{\circ}C$) and room temperature (20$\pm$5$^{\circ}C$)after storage. The physiological properties of garlic were investigated among treatments. The garlic respiration increased after 2 months at room temperature storage, which seem to be dormancy break time. During storage of garlic by CA, MA condition, sprouting and weight loss were prevented effectively by suppress of respiration, and hardness was maintained higher then those of the others. Decay rate occurred 8.1% at room temperature storage, 2% at MA storage but didn't occurred at CA and low temperature storages. When marketed at room and low temperature after storage, increment of respiration and sprouting were delayed, and changes of weight and hardness were low in garlics stored at CA and MA. Decay rate occurred high in garlics stored at MA and room temperature.

  • PDF

A Converging Exact Algorithm for Determining an Optimal 3-Class-Based Dedicated Linear Storage System

  • Yang Moon-Hee
    • Management Science and Financial Engineering
    • /
    • 제12권1호
    • /
    • pp.79-94
    • /
    • 2006
  • In this paper, we readdress a layout design problem, PTL[3], for determining an optimal 3-class-based dedicated linear storage layout in a class of unit load storage systems. Based on some fundamental properties derived, we provide a converging exact algorithm with O(n[logn]), which is more efficient than that of Yang and Kim [8] and can be applied to PTL[K] with $K{\ge}4$ in order to reduce computational execution time. In addition, we prove that the necessary condition suggested by them is also a sufficient condition to PTL[3].

계란의 보관방법에 따른 품질 변화 (Changes of egg quality during storage)

  • 이성모;김경호;홍종해
    • 한국동물위생학회지
    • /
    • 제25권1호
    • /
    • pp.15-22
    • /
    • 2002
  • This experiment was carried out to investigate the changes of egg qualify during storage in order to find out the proper storage condition. Fresh eggs were stored at cold condition ($5^{\circ}C$, relative humidity ; RH :$65\pm$3%) and room condition($25^{\circ}C$, RH :$40\pm$3%) during 10 weeks and examined microbiological quality, weight loss and interior quality periodically. Weight loss was indicated 17.93% at room condition and 2.56% at cold condition. The pH of egg white and yolk were increased from 7.94 to 9.03(average 13.72%) and from 6.16 to 6.57(average 6.65%) at cold condition and from 7.94 to 9.54(average 20.15%) and from 6.16 to 6.90(average 12.01%) at room condition respectively. But pH of egg white and yolk did not showed significant difference between before molting and after molting. Haugh unit was decreased from 82.0 to <30 at room condition after 3 weeks. The most frequent bacteria isolated were E coli, Staphylococcus leutus, S saprophyticus, Citrobacter freundii, Klebsiella oxytoca, Providencia rettgeri, and Pontoea spp. It was recommended that shelf life of unrefrigerated eggs would not be longer than 21 days at room temperature in summer.

저장중 호박분말의 카로테노이드 색소 변화 (Changes of Carotenoids of the Pumpkin Powder during Storage)

  • 박용곤;강윤한;이병우;석호문
    • 한국식품영양과학회지
    • /
    • 제26권1호
    • /
    • pp.32-36
    • /
    • 1997
  • 열풍건조한 호박분말을 2$0^{\circ}C$에서 1개월 저장하였을 때 저장 초기 총 카로테노이드 함량이 14.46mg%이던 것이 저장 1개월후 빛의 유무에 관계없이 약 65~70% 감소하였으며, TLC 분리에서 빛의 영 향에 관계없이 5개 의 반점으로 분리되었으나 저장시일의 경과에 따른 카로테노이드 색소의 차이를 구별하기는 어려웠다. HPLC에서 lutein의 경우 빛을 조사한 분말은 저장 15후 부터 함량이 다소 증가하였고, 빛을 차단한 분말은 1개월간 함량 변화가 일어나지 않았으며, lycopene은 모두 저 장 말기까지 거의 변화가 일어나지 않았다. $\beta$-Carotene 의 경우 빛을 조사한 처리구가 15일경부터 그 함량이 감소한 반면 빛을 차단한 분말은 저장말기에 가서야 감소하였으며, $\alpha$-carotene은 저장 전 기간을 통해 두 처리구 모두 변화를 나타내지 않았다. 색도조사에서 황색 도인 b값은 두처리구 모두 저장 10일 이후부터 감소하 였으나 빛 차단구의 경우가 그 감소폭이 적은 것으로 나타났다.

  • PDF

전력저장장치를 고려한 일간 최적 기동정지계획 수립연구 (Daily Unit Commitment Scheduling of Power System with Energy Storage System)

  • 송하나;장세환;김형중;노재형;박종배
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.717-725
    • /
    • 2011
  • In the power system with an electric storage system that can increase utilization rate of the source of such new renewable energy, this paper introduces the approach on the daily unit commitment scheduling that determines simultaneously optimum operational condition and output of thermal generators and electric storage device. The unit commitment is one of the most important issues in economic operation and security of short-term operational plan of the power system. It is to determine on/off status of generator to minimize operational cost during the given period. The committed generator should satisfy various operational limitation such as estimated demand by system, spinning reserve condition within minimum operational cost. In order to determine on/off or charge/discharge/idle condition and output level of units and electric storage system, the MILP(Mixed Integer Linear Programming) is suggested. The proposed approach is the mixed method between LP(Linear Programming) and IP(integer programming) which seeks the value of real number and integer that maximize or minimize function objective within given condition. The daily unit commitment problem with the electric storage system is applied to MILP algorithm through linearization and formulation process. The proposed approach is applied to the test system.