• Title/Summary/Keyword: Storage System

Search Result 6,934, Processing Time 0.031 seconds

Performance Tests on a Solar Water Heating System in Thermosyphonic Flow (열사이폰식 태양열 온수시스템의 성능실험)

  • Kim, Doo-Chun;Park, Seung-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.2
    • /
    • pp.93-103
    • /
    • 1980
  • A small domestic solar water heating system in thermosyphonic flow was tested in Seoul. The system consisted of four flat plate aluminium roll bond type collectors of total effective area $3.28m^2$ and a $280{\iota}$ storage tank. It was tilted $52^{\circ}$ relative to the horizon. And the collector plate, collector tube and storage tank were equiped with 14 thermocouples. As the results, the following facts were found; 1) To provide water at $55^{\circ}C$ for a family of four in Seoul, a collector area of $3-4m^2$ and a storage capacity of $180{\iota}- 200{\iota}$ are suggested. And this system can supply hot water at above $45^{\circ}C$ day about. 2) In the late afternoon hours, it might be advantageous to stop the flow in the system as heat losses to the environment increase unduly. 3) Without any hot water consumption throughout the day, water temperature distributions inside the storage tank was found almost linear. This indicates essentially no mixing inside the storage tank. 4) In case of a small domestic solar water heating system, it is better to employ a single transparent cover rather than double one.

  • PDF

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

Preservation Environments of Cooperative Library Storage Facilities (공동보존서고의 보존환경에 관한 연구)

  • Cho, Yong-Wan;Rho, Jee-Hyun
    • Journal of Korean Library and Information Science Society
    • /
    • v.44 no.4
    • /
    • pp.367-397
    • /
    • 2013
  • Recently, there are some discussions about cooperative library storage facilities as methods to relieve the pressure from shortage of library stacks in Korea. This study tried to inspect the preservation environments of 16 cooperative storage facilities in USA, Australia, France, Spain and Korea to help to prepare and establish cooperative storage facilities with ideal preservation conditions. To do this, some aspects of the preservation environments including basic conditions shelving system, HVAC(heating, ventilating and air conditioning) system, fire extinguishing system, security system and other preservation environments were compared and analyzed.

Design of Global Buffer Managerin Cluster Shared File Syste (클러스터 공유파일 시스템의 전역버퍼 관리기 설계)

  • 이규웅;차영환
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.1
    • /
    • pp.101-108
    • /
    • 2004
  • As the dependency to network system and demands of efficient storage systems rapidly grows in every networking filed, the current trends initiated by explosive networked data grow due to the wide-spread of internet multimedia data and internet requires a paradigm shift from computing-centric to data-centric in storagesystems. Furthermore, the new environment of file systems such as NAS(Network Attached Storage) and SAN(Storage Area Network) is adopted to the existing storage paradigm for Providing high availability and efficient data access. We describe the design issues and system components of SANiqueTM, which is the cluster file system based on SAN environment. SANiqueTM has the capability of transferring the user data from the network-attached SAN disk to client applications directly We, especially, present the protocol and functionality of the global buffer manager in our cluster file system.

  • PDF

File System for Performance Improvement in Multiple Flash Memory Chips (다중 플래시 메모리 기반 파일시스템의 성능개선을 위한 파일시스템)

  • Park, Je-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.17-21
    • /
    • 2008
  • Application of flash memory in mobile and ubiquitous related devices is rapidly being increased due to its low price and high performance. In addition, some notebook computers currently come out into market with a SSD(Solid State Disk) instead of hard-drive based storage system. Regarding this trend, applications need to increase the storage capacity using multiple flash memory chips for larger capacity sooner or later. Flash memory based storage subsystem should resolve the performance bottleneck for writing in perspective of speed and lifetime according to its physical property. In order to make flash memory storage work with tangible performance, reclaiming of invalid regions needs to be controlled in a particular manner to decrease the number of erasures and to distribute the erasures uniformly over the whole memory space as much as possible. In this paper, we study the performance of flash memory recycling algorithms and demonstrate that the proposed algorithm shows acceptable performance for flash memory storage with multiple chips. The proposed cleaning method partitions the memory space into candidate memory regions, to be reclaimed as free, by utilizing threshold values. The proposed algorithm handles the storage system in multi-layered style. The impact of the proposed policies is evaluated through a number of experiments.

  • PDF

Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank (냉동탑차의 Thermobank 열저장 매체에 따른 냉각성능 비교)

  • Mun, Je-Cheol;Choi, Kwang-Il;Oh, Jong-Taek;Kim, Jai-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.810-814
    • /
    • 2009
  • A experimental study of a high efficiency transport refrigeration system for sliced-raw fish transportation is presented in this paper. The refrigeration system, that is powered by the car engine, is equipped with heat storage for reverse cycle-hot gas defrost; the stored heat is used during defrost cycle of the system. The heat storage has size $400(L){\times}350(W){\times}250(H)\;mm$ and made of fin-tube heat exchanger. System performance and container operating conditions are experimentally investigated and analyzed under cooling and defrosting conditions with heat storage materials. The water is faster about 30% than paraffin in cooling-down time of heat storage materials with load and unload.

  • PDF

The Development of the System Operation Safety of Unmanned Parcel Storage System with ICT and Cold Chain Technology (ICT 콜드체인 기술이 적용된 무인 택배물품 보관장치의 시스템 운영 안전성 확보를 위한 연구)

  • Park, Jae-Min;Kim, Young-Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.3
    • /
    • pp.29-37
    • /
    • 2022
  • The development of technology related to the Fourth Industrial Revolution and the growth of the online market due to pandemic are continuing the growth of the logistics market for product delivery. If it is difficult to deliver the product directly to the customer during delivery, storage and delivery using the unmanned courier box are being carried out. However, existing storage boxes are not actively used due to lack of usability even though they have the advantage of storing goods and delivering non-face-to-face. In addition, existing courier boxes are not prepared for cold chain transportation. The unmanned delivery storage device with ICT cold chain technology should be developed to prepare for the transition to non-face-to-face society, to improve logistics efficiency and meet user's requirements. Also, it is necessary to consider the measures to reduce the safety problems that may occur during the use and maintenance of the automatic system. This study conducted a model-based analysis for the development of unmanned delivery storage devices with ICT cold chain technology, and conducted a study to derive the system development specifications that meet the requirements and secure safety and apply them to the development process.

Review of Aging Management for Concrete Silo Dry Storage Systems

  • Donghee Lee;Sunghwan Chung;Yongdeog Kim;Taehyung Na
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.4
    • /
    • pp.531-541
    • /
    • 2023
  • The Wolsong Nuclear Power Plant (NPP) operates an on-site spent fuel dry storage facility using concrete silo and vertical module systems. This facility must be safely maintained until the spent nuclear fuel (SNF) is transferred to an external interim or final disposal facility, aligning with national policies on spent nuclear fuel management. The concrete silo system, operational since 1992, requires an aging management review for its long-term operation and potential license renewal. This involves comparing aging management programs of different dry storage systems against the U.S. NRC's guidelines for license renewal of spent nuclear fuel dry storage facilities and the U.S. DOE's program for long-term storage. Based on this comparison, a specific aging management program for the silo system was developed. Furthermore, the facility's current practices-periodic checks of surface dose rate, contamination, weld integrity, leakage, surface and groundwater, cumulative dose, and concrete structure-were evaluated for their suitability in managing the silo system's aging. Based on this review, several improvements were proposed.

A SAN Optimization Scheme for High-Performance Storage System (고성능 저장장치를 위한 SAN최적화기법)

  • Lee, In-Seon
    • Journal of Digital Convergence
    • /
    • v.12 no.1
    • /
    • pp.379-388
    • /
    • 2014
  • We noted that substituting hard disk with high-performance storage device on SAN did not immediately result in getting high performance. Investigating the reason behind this leaded us to propose optimization schemes for high-performance storage system. We first got rid of the latency in the I/O process which is unsuitable for the high-performance storage device, added parallelism on the storage server, and applied temporal merge to Superhigh speed network protocol for improving the performance with small random I/O. The proposed scheme was implemented on the SAN with high-performance storage device and we verified that there were about 30% reduction on the I/O delay latency and 200% improvement on the storage bandwidth.

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.