• Title/Summary/Keyword: Storage System

Search Result 6,934, Processing Time 0.039 seconds

Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis (지하대수층을 이용한 축열시스템의 설계(II) : 열해석)

  • Lee, K.S.;Lee, T.H.;Song, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

Cold Energy Storage System Using Direct Contact Heat Transfer (직접 접촉식을 이용한 빙축열 시스템)

  • Lee, Y.P.;Yoon, S.Y.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.247-258
    • /
    • 1994
  • In this study, experimental investigations to find cold energy storage performance have been made for two different temperatures at condenser. Temperatures at inlet and outlet of condenser were measured to calculate global heat transfer coefficient of direct contact method in our cold energy storage system. Also storage performance by direct contact method was compared with that of Ice-On-Coil type ice storage which was calculated by analytic solution. Results show that, in the case of $-8.0^{\circ}C$ at condenser inlet, heat transfer coefficient of direct contact method is 3.25 times higher than that of conventional method and COP of system is improved by using R141b as refrigerant which produces gas hydrate and has higher phase change temperature than $0.0^{\circ}C$.

  • PDF

Modeling of the Inter-Page Interference on the Holographic Data Storage Systems (홀로그래픽 저장장치에서 인접 페이지 간 간섭 모델링)

  • Park, Dong-Hyuk;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.581-586
    • /
    • 2010
  • The holographic data storage system stores multiple data pages by multiplexing. But the inter-page interference(IPI) caused by multiplexing reduces the intensity of the hologram. The simulation of the holographic storage systems has to consider the IPI. Therefore, we introduce a channel modeling that takes care of inter-page interference in the holographic data storage system. We simulate the performance of PRML detection on the hologrpahic data storage system with IPI modeling.

ANALYSIS OF K-CLASS-BASED DEDICATED STORAGE POLICY IN A UNIT LOAD SYSTEM

  • Yang, Moon-Hee;Rhee, Min-Surp
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.505-516
    • /
    • 2007
  • In this paper, we provide some fundamental properties and basic theoretical results of K-class-based dedicated storage policy in a unit load system assuming the constant-space assumption that the number of storage locations for a class is not the maximum aggregate inventory position for a class but the sum of space requirement for products assigned to the class. The main theorem is that there exists a (K+1) -class-based storage layout whose expexted single command (SC) travel time is not greater than that of a K-class-based storage layout, i.e, $E(SC^*_{K+1}){\leq}E(SC^*_K)\;for\;K=1,{\cdots}$, (n-1).

The study of striping size according to the amount of storage nodes in the Parallel Media Stream Server (병렬 미디어 스트림 서버에서 저장노드수의 변화에 따른 스트라이핑 크기 결정에 관한 연구)

  • Kim, Seo-Gyun;Nam, Ji-Seung
    • The KIPS Transactions:PartC
    • /
    • v.8C no.6
    • /
    • pp.765-774
    • /
    • 2001
  • In this paper, we proposed the striping policy for the storage nodes in the Linux-based parallel media stream server. We newly developed a storage clustering architecture, and named it as a system RAID architecture. In this system, many storage cluster nodes are grouped to operate as a single server. This system uses unique striping policy to distribute multimedia files into the parallel storage nodes. If a service request occurs, each storage cluster node transmits striped files concurrently to the clients. This scheme can provide the fair distribution of the preprocessing load in all storage cluster nodes. The feature of this system is a relative striping policy based on the file types, service types, and the number of storage nodes to provide the best service.

  • PDF

A Reliable Secure Storage Cloud and Data Migration Based on Erasure Code

  • Mugisha, Emmy;Zhang, Gongxuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.1
    • /
    • pp.436-453
    • /
    • 2018
  • Storage cloud scheme, pushing data to the storage cloud poses much attention regarding data confidentiality. With encryption concept, data accessibility is limited because of encrypted data. To secure storage system with high access power is complicated due to dispersed storage environment. In this paper, we propose a hardware-based security scheme such that a secure dispersed storage system using erasure code is articulated. We designed a hardware-based security scheme with data encoding operations and migration capabilities. Using TPM (Trusted Platform Module), the data integrity and security is evaluated and achieved.

A Case Study on Active Usage of the Storage Space Outside Housing Unit of Residential Complex (공동주택 세대외부창고의 활성화 방안을 위한 사례 연구)

  • Song, Jihyun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.58-67
    • /
    • 2018
  • This study aims to analyze the cases of storage space outside housing unit and propose the activation plan. The issue of storage in residential complex has continued to be reported. This is more salient due to the recent preference trend for small houses, the constant increase of living goods and the limitation of the available space inside housing unit. Although more apartment houses are trying to have individual storage in the exterior space to address these issues, there is still a paucity of the related studies and more studies are required. In this study, we conducted on-site investigation and user interview of each case to propose active usage of the storage space outside housing unit. Result of this study shows that the most crucial factor to improve is 'accessibility' in order to activate the storage space. Storage room should be located close to each household or the individual parking space. The second factor is the size and the structure of the storage room. The sufficient space for keeping and taking large objects out are required. The front of the storage room should have a clogged structure to insure privacy. The third is the provision of suitable support programs such as the system that occupants can check remotely what items are in their storage rooms, garage sale, laundry service, auto cleaning system and rental program. Those programs are required for efficient management and activation of space. Another requirement is to improve environmental factors which include maintenance of optimal temperature and humidity, automatic ventilation system, control of individual lights, and security enhancement. Based on the results of the survey, we provide basic data which can be used for practical space planning to activate exterior storage space of the housing unit. Further surveys are required to develop this study by obtaining more data for generalization.

Design of Optimized SWAP System for Next-Generation Storage Devices (차세대 저장 장치에 최적화된 SWAP 시스템 설계)

  • Han, Hyuck
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.4
    • /
    • pp.9-16
    • /
    • 2015
  • On modern operating systems such as Linux, virtual memory is a general way to provide a large address space to applications by using main memory and storage devices. Recently, storage devices have been improved in terms of latency and bandwidth, and it is expected that applications with large memory show high-performance if next-generation storage devices are considered. However, due to the overhead of virtual memory subsystem, the paging system can not exploit the performance of next-generation storage devices. In this study, we propose several optimization techniques to extend memory with next-generation storage devices. The techniques are to allocate block addresses of storage devices for write-back operations as well as to configure the system parameters, and we implement the techniques on Linux 3.14.3. Our evaluation through using multiple benchmarks shows that our system has 3 times (/24%) better performance on average than the baseline system in the micro(/macro)-benchmark.

Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System (잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구)

  • Ryu, S.N.;Han, G.Y.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF

The Study on Improvement in Subcooling of TMA Clathrate for PCM in Ice Storage System (빙축열시스템 PCM용 TMA-포접화합물의 과냉도 개선에 대한 연구)

  • Kim, J.H.;Chung, N.K.;Kim, C.O.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1663-1666
    • /
    • 2003
  • TMA clathrate that is used by PCM of ice storage system in this research creates hydrate crystallization at higher temperature than pure water, and application is expected as PCM because having comparative big dormant temperature without phase separation phenomenon. In case this research uses TMA clathrate by PCM, choose admixture by purpose to control or remove subcooling of TMA clathrate and evaluated experimentally. Subcooling is improved and can expect contraction of freezing machine running time and increase of coefficient of performance as that add admixture to TMA clathrate conclusively. Also, may supply thermal storage system that apply low temperature potential heat thermal storage material that subcooling is improved more extensively laying stress on medium size building and small size building, can expect allowance through localization of ice storage system.

  • PDF