• Title/Summary/Keyword: Storage Length Coefficients

Search Result 5, Processing Time 0.021 seconds

A Study on Calculating Relevant Length of Left Turn Storages Using UAV Spatial Images Considering Arrival Distribution Characteristics at Signalized Intersections in Urban Commercial Areas

  • Yang, Jaeho;Kim, Eungcheol;Na, Young-Woo;Choi, Byoung-Gil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.3
    • /
    • pp.153-164
    • /
    • 2018
  • Calculating the relevant length of left turn storages in urban intersections is very crucial in road designs. A left turn lane consists of deceleration lanes and left turn storages. In this study, we developed methods for calculating relevant lengths of left turn storages that vary at each intersection using UAV (Unmanned Aerial Vehicle) spatial images. Problems of conventional design techniques are applying the same number of left turn vehicles (N) using Poisson distribution without considering land use types, using a vehicle length that may not be measurable when applying the length of waiting vehicles (S), and using same storage length coefficient (${\alpha}$), 1.5, for every intersections. In order to solve these problems, we estimated the number of left turn vehicles (N) using an empirical distribution, suggested to use headways of vehicles for (S) to calculate the length of waiting vehicles (S) with a help of using UAV spatial images, and defined ranges of storage length coefficient (${\alpha}$) from 1.0 to 1.5 for flexible design. For more convenient design, it is suitable to classify two cases when possible to know and impossible to know about ratio of large trucks among vehicles when planning an intersection. We developed formula for each case to calculate left turn storage lengths of a minimum and a maximum. By applying developed methods and values, more efficient signalized intersection operation can be accomplished.

Reversible DNA Watermarking Technique Using Histogram Shifting for Bio-Security (바이오 정보보호 위한 히스토그램 쉬프팅 기반 가역성 DNA 워터마킹 기법)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Lee, Eung-Joo;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.244-253
    • /
    • 2017
  • Reversible DNA watermarking is capable of continuous DNA storage and forgery prevention, and has the advantage of being able to analyze biological mutation processes by external watermarking by iterative process of concealment and restoration. In this paper, we propose a reversible DNA watermarking method based on histogram multiple shifting of noncoding DNA sequence that can prevent false start codon, maintain original sequence length, maintain high watermark capacity without biologic mutation. The proposed method transforms the non-coding region DNA sequence to the n-th code coefficients and embeds the multiple bits of the n-th code coefficients by the non-recursive histogram multiple shifting method. The multi-bit embedding process prevents the false start codon generation through comparison search between adjacent concealed nucleotide sequences. From the experimental results, it was confirmed that the proposed method has higher watermark capacity of 0.004-0.382 bpn than the conventional method and has higher watermark capacity than the additional data. Also, it was confirmed that false start codon was not generated unlike the conventional method.

Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger (수평형 지열 히트펌프 시스템의 냉난방 성능 분석)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

Development of Runoff Hydrograph Model for the Derivation of Optimal Design Flood of Agricultural Hydraulic Structures(1) (농업수리구조물의 적정설계홍수량 유도를 위한 유출수문곡선모형의 개발(I))

  • 이순혁;박명근;맹승진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.3_4
    • /
    • pp.34-47
    • /
    • 1995
  • It is experienced fact as a regular annual event that the structure to he designed on unreasonable flood for the agricultural structures including reservoirs have been brought not only loss of lives, but also enormous property damage. For the solution of this problem at issue, this study was conducted to develop an optimal runoff hydrograph model by comparison of the peak flows and time to peak between observed and simulated flows derived by linear time-invariant and linear time-variant models under the condition of having a short duration of heavy rainfall with uniform rainfall intensity at nine small watersheds which are within the range of 55.9 to 140.7 square kilometers in area in Han, Geum, Nagdong and Yeongsan Rivers. The results obtained through this study can be summarized as follows. 1. Storage constants and Gamma function arguments were calculated within the range of 1.2 to 6.42 and of 1.28 to 8.05 respectively by the moment method as the parameters for the analysis of runoff hydrograph based on linear time-invariant model. 2. Parameters for both linear time-invariant and linear time-variant models were calibrated with nine gaged watershed data, using a trial and error method. The resulting parameters including Gamma function argument, N and storage constant, K for linear time-invariant model were related statistically to watershed characteristic variables such as area, slope, length of main stream and the centroid length of the basin. 3. Average relative errors of the simulated peak discharge of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 0.75 and 5.42 percent respectively to the peak of observed runoff hydrographs. Correlation coefficients for the statistical analysis in the same condition were shown to be 0.999 and 0.978 with a high significance respectively. Therefore, it can be concluded that the accuracy of a linear time-variant model is approaching more closely to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 4. Average relative errors of the time to peak of calibrated runoff hydrographs by using linear time-variant and linear time-invariant models were shown to be 16.44 and 19.89 percent respectively to the time to peak of observed runoff hydrographs. Correlation coefficients in the same condition were also shown to be 0.999 and 0.886 with a high significance respectively. 5. It can be seen that the shape of simulated hydrograph based on a linear time- variant model is getting closer to the observed runoff hydrograph than that of a linear time-invariant model in the applied watersheds. 6. Two different models were verified with different rainfall-runoff events from data for the calibration by relative error and correlation analysis. Consequently, it can be generally concluded that verification results for the peak discharge and time to peak of simulated runoff hydrographs were in good agreement with those of calibrated runoff hydrographs.

  • PDF

Differences of Germination Rate, Degree of Solute Leakage and Water Uptake Rate of Soybean Seeds in Two Storage Periods (저장기간에 따른 콩종실의 발아율이, 용출정도 및 수분흡수율의 차이)

  • 손범영;박금룡;김석동;김수희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.95-102
    • /
    • 1996
  • This investigation was conducted to investigate if germination rate, degree of solute leakage and water uptake rate of seeds are a meaningful information for the selection criteria among soybean genotypes and to find out their characteristics in the variable temperature and moisture conditions encounted during long-term warehouse storage. Germination rate in soybean sprouting box and petri dish differed largely among genotypes stored for twenty months but there was little difference when stored for eight months. Length of hypocotyl was shorter at twenty months of storage than at eight months. Degree of solute leakage of Paldalkong and Pulmuwon was twice higher than that of SS88038 lines at twenty months of storage. In 30 minutes after imbibition, water uptake rate in all genotypes stored for twenty months was faster than these stored for eight months, and water uptake rate in Paldalkong and Pulmuwon stored for eight months was 1.5 and 2 times faster than in SS88038 lines. In correlation coefficients, the germination ability and emergence exhibited significantly negative correlation with degree of solute leakage at twenty months of storage. Water uptake rate in soybean seeds stored for eight months had highly significant positive correlation with degree of solute leakage in 30 minutes and one hour after imbibition while for twenty months of storage, it had highly significant positive correlation with that in 30 minutes, one hour and three hours after imbibition. In eight months of storage, the number of open micropyle had positive correlation with water uptake rate at 30 minutes after imbibiton. But in seeds stored twenty months, it wasn't correlated with water uptake.

  • PDF