The 10 Year Implementation Plan for a Global Earth Observation System of Systems (GEOSS), which was endorsed at the Third Earth Observation Summit in Brussels in February, 2005, emphasizes the importance of data management facilities for diverse and large-volume Earth Observation data from inhomogeneous information sources. A three year research plan for addressing this key target of GEOSS has just approved as the first step by the Japanese government. The goals of this research are, (1) to develop a data management core system consisting of data integration and information fusion functions and interoperability and information service functions; (2) to establish data and information flows between data providers and users; (3) to promote application studies of data integration and information fusion, especially in the fields of weather forecasting, flood forecasting, agricultural management, and climate variability and changes. The research group involves leading scientists on information science and technology, who have been developing giant data archive servers, storage area networks, metadata models, ontology for the earth observations. They are closely cooperating with scientists on earth sciences, water resources management, and agriculture, and establishing an effective collaborative research framework.
A fast precise integration method (FPIM) is proposed for solving structural dynamics problems. It is based on the original precise integration method (PIM) that utilizes the sparse nature of the system matrices and especially the physical features found in structural dynamics problems. A physical interpretation of the matrix exponential is given, which leads to an efficient algorithm for both its evaluation and subsequently the solution of large-scale structural dynamics problems. The proposed algorithm is accurate, efficient and requires less computer storage than previous techniques.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.29
no.10
/
pp.89-96
/
2015
Explicit numerical integration methods for power system transient stability simulation require very small time steps to avoid numerical instability. The EXST1 exciter model is a primary source of fast dynamics in power system transients. In case of the EXST1, the required small integration time step for entire system simulation increases the computational demands in terms of running time and storage. This paper presents a practical exciter model reduction approach which allows the increase of the required step size and thus the method can decrease the computational demands. The fast dynamics in the original EXST1 are eliminated in the reduced exciter model. The use of a larger time step improves the computational efficiency. This paper describes the way to eliminate the fast dynamics from the original exciter model based on linear system theory. In order to validate the performance of the proposed method, case studies with the GSO-37 bus system are provided. Comparisons between the original and reduced models are made in simulation accuracy and critical clearing time.
KSCE Journal of Civil and Environmental Engineering Research
/
v.13
no.4
/
pp.51-64
/
1993
Base-isolated liquid storage tanks under seismic loading were tested by the Pseudo-dynamic test method. Substructuring technique in which a mixed integration method was adopted and the liquid tanks were simply modeled as a discrete system. This study gave experimental verification on the advantage of mounting the liquid tanks on base isolators in order to reduce the hydrodynamic forces on the tank wall.
Abel, Avitesh Chandra;Kim, Beom Mu;Jeon, Seong Min;Rajeev, Kumar Piyare;Shiu, Kumar;;;Lee, Sang Il;Oh, Il Hwan;Lee, Sung Ro
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2013.10a
/
pp.435-437
/
2013
This paper proposes a system composed of wireless sensor network and cloud to monitor storage environment of pharmaceutical products. Integration of sensor networks to cloud is an emerging architecture offering the benefits of internet for monitoring to be done easily and remotely from anywhere and anytime and at the same time freeing the sensor network from processing, analysis, computational and storage of sensor data.
The Transactions of the Korean Institute of Electrical Engineers B
/
v.54
no.8
/
pp.387-394
/
2005
This paper deals with the grid-interactive small battery energy storage system, which aims at the integration o( power quality improvement and demand side management. The main purpose of the proposed system is to achieve the peak power cutting and to compensate the current harmonics and reactive power at the point of installation on power distribution for residential homes. paper deals with the grid-interactive small battery energy storage system, In this paper, the basic principle and control algorithm is analyzed, theoretically and the design methodology of the system is discussed. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1 KVA load capacity is presented.
Kang, Shin-Ill;Kim, Seok-Min;Kim, Hong-Min;Lee, Jee-Seung;Lim, Ji-Seok;Busch, Christopher
Transactions of the Society of Information Storage Systems
/
v.2
no.1
/
pp.1-6
/
2006
An optical ROM card system which using an optical probe array generated by Talbot effect was proposed as new robust storage solution. To improve the optical density and to decrease the power consumption of the system, it is very important to make the spot sizes of optical probes smaller as well as to increase the optical efficiency from the light source to optical probes. In this study, a microlens illuminated aperture array for generating high efficiency optical probe away with small beam spot was designed and fabricated using monolithic lithography integration method. The maximum intensity of optical probes of microlens illuminated aperture array increased about 12 times of that of aperture array, and the full width half maximum of the optical probe at Talbot plane generated by microlens illuminated aperture array was $0.77{\mu}m$.
The grid-connected energy storage systems, which could increase the reliability, efficiency, and cleanliness of the grid is presently restricted by the high cost of batteries. This problems could be solved by batteries retired from automotive services. These batteries can provide a low-cost system for energy storage and other applications such as residential applications and renewable energy integration. This paper gives an overview of technical requirements for the re-use of the electric vehicle batteries in energy storage systems.Firstly, the motivation of research is introduced. Secondly, the technologies needed for the re-use of the battery are introduced such asidentification of the battery characteristics, grading of the aged batteries, identification of the state-of-charge and state-of-health of the battery and suitable power electronic converter topologies. In addition the control strategy to maximize the battery lifespan and bypass the faulty batteries is presented and one-stop solution to implement the above mentioned technologies are also given.
Currently, hybridization of energy generator and storage devices is considered to be one of the most important energy-related technologies due to the possibility of replacing batteries or extending the lifetime of a batteries in accordance with increasing battery demand. This review aims to describe current progress on the mechanical energy generator and hybridization of energy generator and energy storage devices for self-powered electronics. First, the research trends related to energy generation devices using piezoelectric and triboelectric effect that convert physical energy into electric energy is introduced. In addition, integration of energy generators and energy storage devices is introduced. In particular, self-charging energy cells provide an innovative approach to the direct conversion of mechanical energy into electrochemical energy to decrease energy conversion loss.
With technological advances for storage volume size of a semiconductor memory, USB storage is made as products to support a high capacity storage. Hereby, consumers discard pint-sized USB storages which they already had, or do not use them efficiently. To integrate and unify these pint-sized USB storages as one big USB storage, we proposed Sigma Hub. It can be grouping multiple USB storages, which have each different volume size of memory storage, as logical unity Storage through USB Hub. The proposed Sigma Hub includes Sigma Controller as a core management module to unify the multiple USB storages in transaction level layer. Sigma controller can efficiently control transaction packet in Sigma Hub through a USB Storage-Integration algorithms which ensure an integrity for data read and write processes. Consequently, Sigma Hub enables the use of USB storage that is logical unity.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.