• Title/Summary/Keyword: Stop line detection

Search Result 27, Processing Time 0.026 seconds

The Decision of the Optimal Shape of Inductive Loop for Real-Time Traffic Signal Control (실시간 교통신호제어를 위한 루프 검지기의 최적형태결정에 관한 연구)

  • 오영태;이철기
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.3
    • /
    • pp.67-86
    • /
    • 1995
  • It requires the detector system which can collect highly reliable traffic data in order to perform the real-time traffic signal control. This study is to decide the optimal shape of inductive loop for the real-time traffic signal control .This loop is located at the stopline in the signalized intersection for DS(Degree of Saturation) control. In order to find out the optimal shape of loop, 6types of experiments were performed . The results of the basic experiments of loops are as follows ; -the optimal number of turns for loop is 3 turns. -the impedance values of the loop detectors are similar to that of NEMA standards -the 1.8${\times}$4.5M loop is excellent for sensitivity in actual detection range of car length comparing to other shape of inductive loops. At the experimental of establishments of the optimal loop shape, it found that 1.8 4.5M loop has the highest values of $\DeltaL$ comparing to other types of loops, It means that the range of Lead-in cable length of this loop. And this loop is highly reliable in occpupancy time. Conclusivley, the 1.8${\times}$4.5M inductive loop is the optimal solution as a stop line loop detector for real -time traffic signal control.

  • PDF

A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication, (2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구)

  • Kim, Jae-Pil;Hyun, Yong-Sub;Chang, Kyong-Song
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

A Study on Point Traffic Sensors' Placement for Detecting the Dilemma Zone Problem (딜레마 구간 검지를 위한 지점교통센서 배치에 관한 연구)

  • Jang, Jeong-Ah;Choi, Kee-Choo;Lee, Sang-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.26-37
    • /
    • 2009
  • This paper suggests a sensor's placement method for detecting the dilemma zone problem when real-time driver's safety service is provided at signalized intersections by multiple pointed traffic sensors using USN environments. For detecting the dangerous situations from vehicles accelerating through yellow intervals, red-light running and stopping abruptly like as dilemma zone problem, VISSIM(microscopic, behavior-based multi-purpose traffic simulation program) is used to perform a real-time multiple detection situation by changing the input data like as various inflow-volume, design speed change, driver perception and response time. As a result, the optimal interval of traffic sensors is 20~27m, and the initialized sensor location from stop-line is different according to road design speed. Moreover, the pattern of detection about dilemma zone is also different according to inflow-volumes. This paper shows that the method is useful to evaluate the sensor's placement problem based on micro-simulation and the results can be used as the basic research for USN services.

  • PDF

The Rapid Detection of Antioxidants from Safflower Seeds (Carthamus tinctorius L.) Using Hyphenated-HPLC Techniques (Hyphenated-HPLC 기술을 활용한 홍화씨의 항산화 성분 분석)

  • Kim, Su-Jin;Kim, Sang-Min;Kang, Suk-Woo;Um, Byung-Hun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.414-419
    • /
    • 2010
  • Hyphenated-HPLC techniques combine the separation power of HPLC with the structural and bioactivity information provided by NMR, ESI/MS, and an on-line antioxidant screening system. The major advantages over the traditional off-line techniques are rapidity and efficiency. In this study, we used hyphenated HPLC techniques including online HPLC-ABTS, LC-NMR, and LC-MS todirectly identify the major antioxidants of safflower (Carthamus tinctorius L.) seeds. The results demonstrated that the major antioxidant compounds from on-line HPLC-ABTS analysis were identified as 8'-hydroxyarcgenin-4'-O-$\beta$-D-glucoside, N-(p-coumaroyl) serotonin, and N-feruloylserotonin. Among them, N-feruloylserotonin accounted for almost 50% of the ABTS radical scavenging activity of the total extract. The results demonstrate that HPLC hyphenated techniques can be used to rapidly screen and structurally identify antioxidants from crude plant extracts.

Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps (소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.

Design of a GCS System Supporting Vision Control of Quadrotor Drones (쿼드로터드론의 영상기반 자율비행연구를 위한 지상제어시스템 설계)

  • Ahn, Heejune;Hoang, C. Anh;Do, T. Tuan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1247-1255
    • /
    • 2016
  • The safety and autonomous flight function of micro UAV or drones is crucial to its commercial application. The requirement of own building stable drones is still a non-trivial obstacle for researchers that want to focus on the intelligence function, such vision and navigation algorithm. The paper present a GCS using commercial drone and hardware platforms, and open source software. The system follows modular architecture and now composed of the communication, UI, image processing. Especially, lane-keeping algorithm. are designed and verified through testing at a sports stadium. The designed lane-keeping algorithm estimates drone position and heading in the lane using Hough transform for line detection, RANSAC-vanishing point algorithm for selecting the desired lines, and tracking algorithm for stability of lines. The flight of drone is controlled by 'forward', 'stop', 'clock-rotate', and 'counter-clock rotate' commands. The present implemented system can fly straight and mild curve lane at 2-3 m/s.