The effects of stirrups and the extents of regions used SFRC in exterior beam-column joints

  • Gencoglu, Mustafa
    • Structural Engineering and Mechanics
    • /
    • 제27권2호
    • /
    • pp.223-241
    • /
    • 2007
  • Seven full-scale exterior beam-column joints were produced and tested under reversible cyclic loads to determine. Two of these seven specimens were produced using ordinary reinforced concrete (RC). Steel Fiber Reinforced Concrete (SFRC) was placed in three different regions of the beams of the rest five specimens to determine the extent of the region where SFRC is the most effective. The extent of the region of SFRC was kept constant at the columns of all five specimens. Three of these five specimens which had one stirrup in the joint, were tested to evaluate the effect of the stirrup on the behavior of the beam-column joint together with SFRC. In production of the specimens with SFRC, all special requirements of the Turkish Earthquake Code related to the spacing of hoops were disregarded. Previous researches reported in the literature indicate that the fiber type, the volume content, and the aspect ratio of steel fibers affect the behavior of beam-column joints produced with SFRC. The results of the present investigation show that the behavior of exterior beam-column joints depends on the extent of the region where SFRC is used and the usage of stirrup in the joint, in addition to the parameters listed in the literature.

Cyclic flexural behavior of RC members reinforced with Forta-Ferro and Polyvinyl Alcohol fibers

  • Hamed Rajabzadeh Gatabi;Habib Akbarzadeh Bengar;Murude Celikag
    • Structural Engineering and Mechanics
    • /
    • 제87권4호
    • /
    • pp.333-346
    • /
    • 2023
  • This paper presents findings from an experimental study that was focused on evaluating the use of Forta-Ferro (FF) and Polyvinyl Alcohol (PVA) fibers on the response of moderate and special ductility beams under load cycles. For this reason, eight full-scale specimens, identical in geometry, were subjected to gradual cyclic loading. The specimens included two plain concrete beams with medium and special ductility, three beams with medium ductility and stirrup spacing of one-quarter the effective depth (d/4) and three beams with special ductility, and stirrup spacing of one-half the effective depth (d/2), strengthened with FF and PVA fibers separately. The use of fibers was aimed at reducing the amount of shear reinforcement in flexural members. Here, the variation of parameters including the maximum strength, ultimate strength, stiffness, ductility, damage index, energy dissipation, and equivalent damping was studied. Utilizing FF and PVA fibers improved the performance in beams with moderate ductility when compared to those beams with special ductility. Therefore, in special ductility beams, fibers can be used instead of crossties and in moderate ductility beams, fibers can be added to reduce the ratio of shear reinforcement. Furthermore, increasing the stirrup spacing in the moderate ductility beams from d/4 to d/2 and adding 0.6% FF or 1.5% PVA fibers resulted in behavior similar to those of the moderate ductility beam.

강섬유와 묶음철근 보강을 통한 고성능 연결보의 이력거동 평가 (Hysteretic Behavior Evaluation of a RC Coupling Beam using a Steel Fiber and Diagonal Reinforcement)

  • 오해철;이기학;한상환;신명수;조영욱
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.291-298
    • /
    • 2015
  • 본 논문은 시공성과 내진성능을 증대하기 위해 고성능 강섬유를 혼합한 묶음대각철근 연결보를 제시한다. 연결보의 실험은 4개의 실험체로 구성하고 고성능 강섬유를 혼합한 실험체에 반복하중을 가하여 이력거동을 비교 평가하였다. 실험의 주요 변수는 강섬유의 혼합에 따라 대각철근의 묶음 여부와 스터럽의 철근량이다. 기준이 되는 실험체는 묶음대각철근에 ACI318에서 요구하는 스터럽의 철근량을 100% 적용하였다. 이와 함께, 동일한 묶음대각철근을 적용한 상태에서 스터럽의 철근량을 75%와 50%로 조절하여 두 실험체를 추가적으로 만들고 일반대각철근을 고려, 총 4개의 실험체가 제작되었다. 이번 실험에서 연결보의 콘크리트 타설시 고성능 강섬유를 함유율 1%로 혼합하였다. 모든 실험체는 1/2스케일로 형상비 3.5(l/h=1050/300)으로 이루어졌다. 본 실험결과에서 강섬유를 1% 혼입한 고성능 시멘트를 적용한 연결보는 스터럽 철근양을 75%, 50% 줄인 것과 기준실험체로 적용된 스터럽 철근양 100%의 강도 및 강성, 에너지소산능력에서 큰 차이를 보이지 않았다.

전단보강된 고강도경량콘크리트 보의 휨거동에 관한 연구 (A Study on the Flexural Behavior of Reinforced High Strength Lightweight Concrete Beams With Web Reinforcement)

  • 오창륜;김재식;곽윤근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.513-518
    • /
    • 1998
  • In general, flexural strength and ductility of reinforced concrete beam with stirrup depend on the compressive strength of concrete and longitudinal steel ratio. In this study, nine reinforced high strength lightweight concrete beams and three reinforced normalweight concrete beams with stirrup were tested to investigate their behavior and to determine their ultimate moment capacity. The variable were strength of concrete (400, 500kg/$\textrm{cm}^2$) and the ratio of tensile steel content to the ratio of the balanced steel content(0.22<$\rho$/$$\rho$_b$<0.56). Test results are presented in terms of load-deflection behavior, ductility index, and cracking patterns.

  • PDF

휨거동을 만족하는 강섬유보강 철근콘크리트보의 최적화 (Optimization of Reinforced Steel Fibrous Concrete Beam for the Objective Flexural Behavior)

  • 이차돈;안지현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.541-546
    • /
    • 1998
  • The use of steel fibers in conventional reinforced concrete increases the strength and ductility under various loading conditions. In order to examine the possibility of the use of these combinations achieving required strength and ductility of a reinforced concrete beam, a refined optimization procedure based on nonlinear layered finite element method and nonlinear programming technique is developed in this study. Six design variables-beam width and depth, fiber volume fraction, amounts of tensile and compressive rebars, and stirrup, and stirrup spacing-are considered. The developed model can be used as a tool in determining the economical use of steel fibers in designing the reinforced steel fibrous concrete beam.

  • PDF

슬래브-기둥 접합부의 내진성능을 위한 래티스 전단보강 (Lattice Shear Reinforcement for Earthquake-Resistance of Slab-Column Connection.)

  • 김유니;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.26-29
    • /
    • 2006
  • A flat plate-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In present study, experimental tests were performed to study the capacity of slab-column connections strengthened with lattice, stud rail, shear band and stirrup under gravity and cyclic lateral load. Among them, the capacity of the specimens with lattice are superior to the others due to the truss action of the lattice bars and dowel action of the longitudinal bars as well as the shear resistance of the web re-bar. On the other hand, the strengths of the specimens with stud rail, shear band and stirrup are lower than the estimated strength by the ACI, therefore design formulas of the ACI are needed to revise.

  • PDF

Steel-CFRP composite and their shear response as vertical stirrup in beams

  • Uriayer, Faris A.;Alam, Mehtab
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1145-1160
    • /
    • 2015
  • An experimental study was conducted for the effectiveness of steel-CFRP composite (CFRP laminates sandwiched between two steel strips) as stirrups in concrete beam to carry shearing force and comparison was made with conventional steel bar stirrups. A total numbers of 8 concrete beams were tested under four point loads. Each beam measured 1,600 mm long, 160 mm width and 240 mm depth. The beams were composed of same grade of concrete, with same amount of flexural steel but different shear reinforcements. The main variables include, type of stirrups (shape of stirrups and number of CFRP layers used in each stirrup) and number of stirrups used in shear spans. After getting on an excellent closeness between the values of ultimate shear resistance and ultimate tensile load of steel-CFRP stirrups, it could be concluded that the steel-CFRP stirrups represent the effective solution of premature failure of FRP stirrups at the bends.

Experimental study on seismic performance of coupling beams not designed for ductility

  • Lam, S.S.E.;Wu, B.;Liu, Z.Q.;Wong, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제28권3호
    • /
    • pp.317-334
    • /
    • 2008
  • Seismic performance of coupling beams not designed for ductility is examined. Eight 1:4 scale coupling beam specimens, with seven reinforced concrete sections and one composite section, were tested under cycles of push-pull action. Characteristics of the specimens include moderate shear span ratio in the range of 2.5-3.5, high main reinforcement ratio at 3-4% and small to large stirrup spacing with 90- degree hooks. All the reinforced concrete specimens failed in a brittle manner. Displacement ductility of specimens with large stirrup spacing (${\geq}$140 mm) is in the range of 3 to 5. Seismic performance of the specimens is also examined using the ultimate drift angle and the amount of energy dissipated. Correlating the test data, an empirical relationship is proposed to estimate the ultimate drift angle of a class of coupling beams considered in the study not designed for ductility.

Seismic performance and damage evaluation of concrete-encased CFST composite columns subjected to different loading systems

  • Xiaojun Ke;Haibin Wei;Linjie Yang;Jin An
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.121-134
    • /
    • 2023
  • This paper tested 11 concrete-encased concrete-filled steel tube (CFST) composite columns and one reinforced concrete column under combined axial compression and lateral loads. The primary parameters, including the loading system, axial compression ratio, volume stirrup ratio, diameter-to-thickness ratio of the steel tube, and stirrup form, were varied. The influence of the parameters on the failure mode, strength, ductility, energy dissipation, strength degradation, and damage evolution of the composite columns were revealed. Moreover, a two-parameter nonlinear seismic damage model for composite columns was established, which can reflect the degree and development process of the seismic damage. In addition, the relationships among the inter-story drift ratio, damage index and seismic performance level of composite columns were established to provide a theoretical basis for seismic performance design and damage assessments.

Strain interaction of steel stirrup and EB-FRP web strip in shear-strengthened semi-deep concrete beams

  • Javad Mokari Rahmdel;Erfan Shafei
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.383-393
    • /
    • 2023
  • Conventional reinforced concrete design codes assume ideal strain evolution in semi-deep beams with externally bonded fiber-reinforced polymer (EB-FRP) web strips. However, there is a strain interaction between internal stirrups and web strips, leading to a notable difference between code-based and experimental shear strengths. Current study provides an experiment-verified detailed numerical framework to assess the potential strain interaction under quasi-static monotonic load. Based on the observations, steel stirrups are effective only for low EB-FRP amounts and the over-strengthening of semi-deep beams prevents the stirrups from yielding, reducing its shear strength contribution. A notable difference is detected between the code-based and the study-based EB-FRP strain values, which is a function of the normalized FRP stress parameter. Semi-analytical relations are proposed to estimate the effective strain and stress of the components considering the potential strain interaction. For the sake of simplification, a linearized correction factor is proposed for the EB-FRP web strip strain, assuming its restraining effect as constant for all steel stirrup amounts.