• Title/Summary/Keyword: Sterilization Efficiency

Search Result 71, Processing Time 0.027 seconds

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.

Water Properties of Electrolytic Machine by Stainless Diaphragm and Effects of Electrolytic Ice Water Storage For Keeping Freshness of Squid, Todarodes pacificus (스테인레스 극판을 이용한 전해수장치의 수질특성과 오징어 선도유지를 위한 전해수 빙장 효과)

  • Lee, Nahme-Gull
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.293-301
    • /
    • 2006
  • This study was undertaken to prolonging the freshness in Squid(Todarodes pacificus) on the effects of ice storage methods(tap water ice, electrolytic water ice) using stainless diaphragm electrolytic instrument and also test an efficiency of instrument. Basically, stainless diaphragm electrolytic instrument studied for changes of pH on difference water flow and ampere. The lower water flower and higher ampere made low pH on acid part of electrolytic instrument. Squid samples were stored in tap water ice, acid part of electrolytic water and base part of electrolytic water and used in studying the changes of VBN and skin color through storage. Acid water had strong sterilization effects and VBN was lower levels of acid water than the others. Base water had not sterilization effects. Tap water ice storage was more sterilizing effects than base water ice storage but less effects than acid water ice storage. Lightness of Squid skin showed getting decrease at storage of ice water of all storage methods but acid water ice storage showed more retarding than the other two storage. From these results, it could be suggested that acid electric water ice storage is effective in extendance the shelf-life of squid at chilled storage.

Modeling the Chemical Kinetics of Atmospheric Plasma

  • Kim, Ho-Yeong;Lee, Hyeon-U;Kim, Gyu-Cheon;Lee, Jae-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.270-270
    • /
    • 2012
  • Low temperature atmospheric pressure plasmas (APPs) have been known to be effective for living cell inactivation in the water [1]. Many earlier research found that pH level of the solution was changed from neutral to acidic after plasma treatment. The importance of the effect of acidity of the solution for cell treatments has already been reported by many experiments. In addition, several studies have demonstrated that the addition of a small amount of oxygen to pure helium results in higher sterilization efficiency of APPs [2]. However, it is not clear yet which species are key factors for the cell treatment. To find key factors, we used GMoo simulation. We elucidate the processes through which pH level in the solution is changed from neutral to acidic after plasma exposure and key components with pH and air variation with using GMoo simulation. First, pH level in a liquid solution is changed by He+ and He(21S) radicals. Second, O3 density decreases as pH level in the solution decreases and air concentration decreases. It can be a method of removing O3 that cause chest pain and damage lung tissue when the density is very high. H2O2, HO2 and NO radicals are found to be key factors for cell inactivation in the solution with pH and air variation.

  • PDF

Plasma Medicine: How can Nonthermal Atmospheric Plasma be Applied to Medicine? (플라즈마 메디신: 저온 상압 플라즈마는 어떻게 의학분야에 적용될 수 있는가?)

  • Park, Sang Rye;Hong, Jin Woo;Lee, Hae June;Kim, Gyoo Cheon
    • Journal of Life Science
    • /
    • v.23 no.6
    • /
    • pp.838-846
    • /
    • 2013
  • As a forth state of material, plasma is ionized gas, which generates characteristically various reactive species. After late of $20^{th}$ century, plasma has been widely used in industry. After nonthermal atmospheric plasma was developed, it has been applied to biomedical fields. Nonthermal atmospheric plasma does not give thermal damages to human tissues, and it shows the high efficiency in cancer treatment, sterilization, tooth bleaching, coagulation, and wound healing. Because the application of plasma to biomedicine has been expanded through interdisciplinary studies, its value of high medical technology is increasing now. Since nonthermal atmospheric plasma was first applied to the mammalian cells and microorganisms, many valuable studies has been performed for about last 10 years, so that now the new research area called 'plasma medicine' has been formed. This article introduces the recent data resulted from plasma medicine and helps to understand the plasma medicine.

Electricity Production from Fe[III]-reducing Bacterium Geobacter sulfurreducens in Microbial Fuel Cell (미생물 연료전지에서 Fe[III] 환원 미생물 Geobacter sulfurreducens를 이용한 전기 생산)

  • Lee, Yu-Jin;Oh, You-Kwan;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.6
    • /
    • pp.498-504
    • /
    • 2008
  • Metal-reducing bacterium, Geobacter sulfurreducens is available for mediator-less microbial fuel cell (MFC) because it has biological nanowires(pili) which transfer electrons to outside the cell. In this study, in the anode chamber of the MFC system using G. sulfurreducens, the concentrations of NaCl, sodium phosphate and sodium bicarbonate as electrolytes were mainly optimized for the generation of electricity from acetate. 0.4%(w/v) NaClO and 0.5M $H_2SO_4$ could be utilized for the sterilization of acrylic plates and proton exchange membrane (major construction materials of the MFC reactor), respectively. When NaCl concentration in anode phosphate buffer increased from 5 to 50 mM, power density increased from 6 to $20\;mW/m^2$. However, with increasing sodium phosphate buffer concentration from 5 to 50 mM, power density significantly decreased from 18 to $1\;mW/m^2$. Twenty-four mM sodium bicarbonate did not affect electricity generation as well as pH under 50 mM phosphate buffer condition. Optimized anode chamber of MFC using G. sulfurreducens generated relatively high power density ($20\;mW/m^2$) with the maximum coulombic efficiency (41.3%).

Effect of Forceps Jars with Holes on the Drying Time, Rate of Wet Pack, Cost of Rewashing Linen and Maintenance of Sterilization (타공작업이 이동겸자의 건조시간, Wet Pack율, 린넨 세탁비용 및 오염여부에 미치는 영향)

  • Kang, Mi-Ae
    • The Korean Journal of Health Service Management
    • /
    • v.11 no.4
    • /
    • pp.203-211
    • /
    • 2017
  • Objectives : This study aims to design a method for drying forceps jars. As part of the process, holes were made in the forceps jars. Drying time, rate of wet pack, and cost of rewashing linen were then determined. Moreover, the study looked into the bacteria incidence rate in the forceps jars. This study suggests a practical way for preventing infection in a hospital through a surgical device. Methods : This study investigated the effect of forceps jars with holes on reducing drying time, rate of wet pack, and cost of rewashing linen. It also looked into the bacteria incidence rate in the forceps jars through a parallel design. Data was collected and analyzed using SPSS version 21. Results : The drying time of a forceps jars was remarkably reduced from $18.44{\pm}0.2$ minutes(non-hole forceps jars) to $0.58{\pm}0.02$ minutes(4-hole forceps jars). The rate of wet pack of non-hole forceps jars was 51.4%. However, the rate of 4-hole forceps jars reached 4.6%. The cost of rewashing linen saw a decline from 38,073 won to 3,381 won. In addition, no bacteria and virus were detected from the 24-hours usage of forceps jars even though the jars had holes. Conclusions : The 4-hole forceps jars greatly increased work efficiency as a result of the reduced drying time, rate of wet-pack and cost of rewashing linen. The 4-hole forceps jars did not influence their sterilizing effect.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Ethanol Fermentation of Fusant between Heterologous Transformant of Saccharomyces cerevisiae and Candida tropicalis in Pilot Scale (Pilot Scale에서의 Fusant의 Ethanol 발효)

  • Seu, Jung-Hwn;Kim, Young-Ho;Lee, Soon-Mo;Bang, Byung-Ho
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.1
    • /
    • pp.14-18
    • /
    • 1989
  • As the final experiment to assess the possibility of industrial application of FSC14-75, ethanol productivity from liquefied sweet potato starch was examined in a pilot scale of 300 liters. FSC14-75 produced 6.6%(v/v) of ethanol from 13.3% of liquefied sweet potato starch in 8 days, and the residual sugar was 3.15%. The corresponding efficiency was 70% of the theoretical maximum. Since we could isolate unicellular cell and flocculent cell from the fermentation broth, we designated them FSC14-75(S) and FSC14-75(F), respectively. We investigated ethanol productivity of FSC14-75(F) compared with that of FSC14-75(S) from liquefied potato starch in a mini·tar tormentor scale of 2.5 liters. FSC14-75(F) was found more favorable than the counterpart in terms of ethanol productivity, and produced 8.1%(v/v) of ethanol from 15% of liquefied potato starch with an efficiency of 75%. In a pilot scale fermentation with 15% of liquefied sweet potato starch, ethanol productivity of FSC14-75(F) reached maximum level of 7.7%(v/v) after 8 days, and the residual sugar was 1.9%. However, the ethanol productivity was not enhanced by a supplementary addition of Thermamyl to the fermentation broth after sterilization.

  • PDF

Fabrication of TiO2 Impregnated Stainless Steel Fiber Photocatalyts and Evaluation of Photocatalytic Activity (TiO2 담지 스테인리스 강 섬유 광촉매 제조 및 광촉매 활성 평가)

  • Song, Sun-Jung;Kim, Kyoung Seok;Kim, Kyung Hwan;Li, Hui Jie;Cho, Dong Lyun;Kim, Jong Beom;Park, Hee Ju;Shon, Hokyong;Kim, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.19 no.6
    • /
    • pp.674-679
    • /
    • 2008
  • $TiO_2$ impregnated stainless steel fiber photocatalysts ($TiO_2/SSF$) were fabricated to overcome inherent problems of powdery $TiO_2$ photocatalysts in water treatment. Adhesion strength of the impregnated $TiO_2$ was examined using an ultrasonic-cleaner. Photocatalytic activity was evaluated through decomposition experiment of methylene blue and formic acid. Bactericidal efficiency was evaluated through sterilization experiment of E. Coli and Vibrio Vulnificus. Adhesion strength of the impregnated $TiO_2$ was so high that more than 95% was left over even after the treatment in an ultrasonic-cleaner for 30 min. Methylene blue and formic acid were decomposed as much as 60% and 38% of the initial concentration and more than 99.9% of E. Coli and Vibrio Vulnificus were killed after 1 hour exposure to the prepared photocatalyst under UV irradiation. In the case of decomposition of formic acid, decomposition ratio increased if oxidants were added. Especially the decomposition ratio increased as high as 80% when hydrogen peroxide was added as an oxidant.