• Title/Summary/Keyword: Stereotactic techniques

Search Result 30, Processing Time 0.051 seconds

Comparison of the Dose Distributions with Beam Arrangements in the Stereotactic Body Radiotherapy (SBRT) for Primary Lung Cancer (원발성 폐암에서 정위적 체부 방사선치료의 빔 배열에 따른 선량분포의 비교)

  • Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.110-115
    • /
    • 2014
  • To compare 2 beam arrangements, circumferential equally angles (EA) beams or partially angles (PA) beams for stereotactic body radiation therapy (SBRT) of primary lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target, ipsilateral lung, contralateral lung, and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 12 patients, four treatment plans were generated per data sets ($IMRT_{EA}$, $IMRT_{PA}$, $VMAT_{EA}$, $VMAT_{PA}$). The prescribed dose (PD) was 60 Gy in 4 fractions to 95% of the planning target volume (PTV) for a 6-MV photon beam. When compared with the IMRT and VMAT treatment plan for 2 beams, conformity index, homogeneity index, high dose spillage, D2 cm (Dmax at a distance ${\geq}2cm$ beyond the PTV), R50 (ratio of volume circumscribed by the 50% isodose line and the PTV), resulted in similar. But Dmax of the Organ at risk (OAR), spinal cord, trachea, resulted in differ between four treatment plans. Especially $HDS_{location}$ showed big difference in 21.63% vs. 26.46%.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

MRI-Guided Breast Intervention: Biopsy and Needle Localization (자기공명영상 유도하 유방의 중재적시술: 조직생검술 및 침위치결정술)

  • Ga Eun Park;Jeongmin Lee;Bong Joo Kang;Sung Hun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.345-360
    • /
    • 2023
  • In Korea, the number of institutions providing breast MRI, as well as the number of breast MRIs, has recently increased. However, MRI-guided procedures, including biopsy and needle localization, are rarely performed compared to ultrasound-guided or stereotactic biopsy. As breast MRI has high sensitivity but limited specificity, lesions detected only on MRI require pathologic confirmation through MRI-guided biopsy or surgical excision with MRI-guided needle localization. Thus, we aimed to review MRI-guided procedures, including their indications, techniques, procedural considerations, and limitations.

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea (국내 선형가속기의 포괄적인 품질관리체계에 대한 제언)

  • Choi, Sang Hyoun;Park, Dong-wook;Kim, Kum Bae;Kim, Dong Wook;Lee, Jaiki;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.294-303
    • /
    • 2015
  • American Association of Physicists in Medicine (AAPM) Published Task Group 40 report which includes recommendations for comprehensive quality assurance (QA) for medical linear accelerator in 1994 and TG-142 report for recommendation for QA which includes procedures such as intensity-modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) in 2010. Recently, Nuclear Safety and Security Commission (NSSC) published NSSC notification no. 2015-005 which is "Technological standards for radiation safety of medical field". This notification regulate to establish guidelines for quality assurance which includes organization and job, devices, methods/frequency/tolerances and action levels for QA, and to implement quality assurance in each medical institution. For this reason, all of these facilities using medical machine for patient treatment should establish items, frequencies and tolerances for proper QA for medical treatment machine that use the techniques such as non-IMRT, IMRT and SRS/SBRT, and perform quality assurance. For domestic, however, there are lack of guidelines and reports of Korean Society of Medical Physicists (KSMP) for reference to establish systematic QA report in medical institutes. This report, therefore, suggested comprehensive quality assurance system such as the scheme of quality assurance system, which is considered for domestic conditions, based the notification of NSSC and AAPM TG-142 reports. We think that the quality assurance system suggested for medical linear accelerator also help establishing QA system for another high-precision radiation treatment machines.

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Dose Distributions for Ll NAC Radiosurgery with Dynamically Shaping Fields (선형가속기를 이용한 방사선 수술시 Dynamical Field Shaping에 의한 선량분포)

  • Suh Tae Suk;Yoon Sei Chul;Kim Moon Chan;Jang Hong Seok;PArk Yong Whee;Shinn Kyung Sub;Park Charn Il;Ha Sung Whan;Kang Wee Saing
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.431-437
    • /
    • 1993
  • An important problem in radiosurgery is the utilization of the proper beam parameters, to which dose shape is sensitive. Streotactic radiosurgery techniques for a linear accelerator typically, use circular radiation fields with multiple arcs to produce an spherical radiation distribution. Target volumes are irregular in shape for a certain case, and spherical distributions can irradiate normal tissues to high dose as well as the target region. The current improvement to dose distribution utilizes treating multiple isocenters or weighting various arcs to change treatment volume shape. in this paper another promising study relies upon dynamically shaping the treatment beam to fit the beam's eye view of the target. This conformal irradiation technique was evaluated by means of visual three dimensional dose distribution, dose volume histograms to the target volume and surrounding normal brain. It is shown that using even less arcs than multiple isocenter irradiation technique, the conformal therapy yields comparable dose gradients and superior homogeneity of dose within the target volume.

  • PDF