• Title/Summary/Keyword: Stereotactic radiation therapy

Search Result 142, Processing Time 0.023 seconds

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

Evaluation of usefulness for Stereotactic Partial Breast Irradiation(S-PBI) by using Surface Fiducial Marker (표면위치표지자를 적용한 정위적 부분유방방사선치료의 유용성 평가)

  • Kim, JongYeol;Jung, DongMin;Kim, SeYoung;Yoo, HyunJong;Choi, JungHoan;Park, HyoKuk;Baek, JongGeol;Lee, SangKyu;Cho, JeongHee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.99-108
    • /
    • 2021
  • Purpose: The goal of this study is to evaluate usefulness of noninvasive method instead of previous inserting Fiducial Marker Method when performing Stereotactic Partial Breast Irradiation in CyberKnife. Material and methods: For consistency of Imaging Center, we evaluated both oblique images at angle 45 and 315 acquired from 2D Simulator and CyberKnife quantitatively through dice similarity coefficient. Also, location reproducibility of Surface Fiducial Marker was analyzed from 2D Simulator, treatment plans and CyberKinfe images by using 8 Fiducial Markers made of gold attached to ATOM Phantom based on our institution's protocols. Results: The results of the estimated consistency were 0.87 and 0.9 at the oblique angle 45 and 315, respectively. For location consistency of Surface Fiducial Markers, values of horizontal vertical direction of left breast were Superior/Inferior 0.3 mm, Left/Right -0.3 mm, Anterior/Posterior 0.4 mm, and the values of rotational direction were Roll 0.3 °, Pitch 0.2 °, Yaw 0.4 °. The values of horizontal vertical direction of right breast were Superior/Inferior -0.1 mm, Left/Right -0.1 mm, Anterior/Posterior -0.1 mm, and the values of rotational direction were Roll 0.2°, Pitch 0.1°, Yaw 0.1°. Conclusions: We expect that the protocols used by Surface Fiducial Markers when performing Stereotactic Partial Breast Irradiation in CyberKnife will provide protection from pain and cut expenses for treatment and reduce treatment errors and make treatment more accurate by suggesting treatment protocols based on high consistency of Imaging Center and reproducibility of Fiducial Markers.

Contemporary treatment with radiosurgery for spine metastasis and spinal cord compression in 2015

  • Ryu, Samuel;Yoon, Hannah;Stessin, Alexander;Gutman, Fred;Rosiello, Arthur;Davis, Raphael
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • With the progress of image-guided localization, body immobilization system, and computerized delivery of intensity-modulated radiation delivery, it became possible to perform spine radiosurgery. The next question is how to translate the high technology treatment to the clinical application. Clinical trials have been performed to demonstrate the feasibility of spine radiosurgery and efficacy of the treatment in the setting of spine metastasis, leading to the randomized trials by a cooperative group. Radiosurgery has also demonstrated its efficacy to decompress the spinal cord compression in selected group of patients. The experience indicates that spine radiosurgery has a potential to change the clinical practice in the management of spine metastasis and spinal cord compression.

Development of Electronic Portal Imaging Device and Treatment Position Verification for Fractionated Stereotatic Radiotherapy

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Chilgoo Byun;Hong, Seung-Hong;Rhee, Soo-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.446-449
    • /
    • 2002
  • The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.

  • PDF

Use of Flattening Filter Free Photon Beams for Off-axis Targets in Conformal Arc Stereotactic Body Radiation Therapy

  • Smith, Ashley;Kim, Siyong;Serago, Christopher;Hintenlang, Kathleen;Ko, Stephen;Vallow, Laura;Peterson, Jennifer;Hintenlang, David;Heckman, Michael;Buskirk, Steven
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.288-297
    • /
    • 2014
  • Dynamic conformal arc therapy (DCAT) and flattening-filter-free (FFF) beams are commonly adopted for efficient conformal dose delivery in stereotactic body radiation therapy (SBRT). Off-axis geometry (OAG) may be necessary to obtain full gantry rotation without collision, which has been shown to be beneficial for peripheral targets using flattened beams. In this study dose distributions in OAG using FFF were evaluated and the effect of mechanical rotation induced uncertainty was investigated. For the lateral target, OAG evaluation, sphere targets (2, 4, and 6 cm diameter) were placed at three locations (central axis, 3 cm off-axis, and 6 cm off-axis) in a representative patient CT set. For each target, DCAT plans under the same objective were obtained for 6X, 6FFF, 10X, and 10FFF. The parameters used to evaluate the quality of the plans were homogeneity index (HI), conformality indices (CI), and beam on time (BOT). Next, the mechanical rotation induced uncertainty was evaluated using five SBRT patient plans that were randomly selected from a group of patients with laterally located tumors. For each of the five cases, a plan was generated using OAG and CAG with the same prescription and coverage. Each was replanned to account for one degree collimator/couch rotation errors during delivery. Prescription isodose coverage, CI, and lung dose were evaluated. HI and CI values for the lateral target, OAG evaluation were similar for flattened and unflattened beams; however, 6FFF provided slightly better values than 10FFF in OAG. For all plans the HI and CI were acceptable with the maximum difference between flattened and unflattend beams being 0.1. FFF beams showed better conformality than flattened beams for low doses and small targets. Variation due to rotational error for isodose coverage, CI, and lung dose was generally smaller for CAG compared to OAG, with some of these comparisons reaching statistical significance. However, the variations in dose distributions for either treatment technique were small and may not be clinically significant. FFF beams showed acceptable dose distributions in OAG. Although 10FFF provides more dramatic BOT reduction, it generally provides less favorable dosimetric indices compared to 6FFF in OAG. Mechanical uncertainty in collimator and couch rotation had an increased effect for OAG compared to CAG; however, the variations in dose distributions for either treatment technique were minimal.

Stereotactic Radiotherapy by 6MV Linear Accelerator (6MV 선형가속기를 이용한 정위다방향 단일 고선량 조사)

  • Oho, Yoon-Kyeong;Kim, Mi-Hee;Gil, Hak-Jun;Yoon, Sei-Chul;Lee, Jae-Moon;Choi, Kyu-Ho;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Moon-Chan;Kang, Joon-Ki;Song, Jin-Un
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.269-276
    • /
    • 1988
  • Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngiom (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be peformed safely with a radiation dose of 12-30 Gy. So this nonivasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT.

  • PDF

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

Evaluation of Retro recon for SRS planning correction according to the error of recognize to coordinate (SRS의 좌표 인식 오류 시 Retro recon을 이용한 수정 방법에 관한 평가)

  • Moon, hyeon seok;Jeong, deok yang;Do, gyeong min;Lee, yeong cheol;Kim, sun myung;Kim, young bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate the Retro recon in SRS planning using BranLAB when stereotactic location error occurs by metal artifact. Materials and Methods : By CT simulator, image were acquired from head phantom(CIRS, PTW, USA). To observe stereotactic location recognizing and beam hardening, CT image were approved by SRS planning system(BrainLAB, Feldkirchen, Germany). In addition, we compared acquisition image(1.25mm slice thickness) and Retro recon image(using for 2.5 mm, 5mm slice thickness). To evaluate these three images quality, the test were performed by AAPM phantom study. In patient, it was verified stereotactic location error. Results : All the location recognizing error did not occur in scanned image of phantom. AAPM phantom scan images all showed the same trend. Contrast resolution and Spatial resolution are under 6.4 mm, 1.0 mm. In case of noise and uniformity, under 11, 5 of HU were measured. In patient, the stereotactic location error was not occurred at reconstructive image. Conclusion : For BrainLAB planning, using Retro recon were corrected stereotactic error at beam hardening. Retro recon may be the preferred modality for radiation treatment planning and approving image quality.

  • PDF