• Title/Summary/Keyword: Stereotactic Radiosurgery

Search Result 201, Processing Time 0.038 seconds

Reliability of Stereotactic Coordinates of 1.5-Tesla and 3-Tesla MRI in Radiosurgery and Functional Neurosurgery

  • Kim, Hae Yu;Lee, Sun-Il;Jin, Seong Jin;Jin, Sung-Chul;Kim, Jung Soo;Jeon, Kyoung Dong
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.136-141
    • /
    • 2014
  • Objective : The aims of this study are to identify interpersonal differences in defining coordinates and to figure out the degree of distortion of the MRI and compare the accuracy between CT, 1.5-tesla (T) and 3.0T MRI. Methods : We compared coordinates in the CT images defined by 2 neurosurgeons. We also calculated the errors of 1.5T MRI and those of 3.0T. We compared the errors of the 1.5T with those of the 3.0T. In addition, we compared the errors in each sequence and in each axis. Results : The mean difference in the CT images between the two neurosurgeons was $0.48{\pm}0.22mm$. The mean errors of the 1.5T were $1.55{\pm}0.48mm$ (T1), $0.75{\pm}0.38$ (T2), and $1.07{\pm}0.57$ (FLAIR) and those of the 3.0T were $2.35{\pm}0.53$ (T1), $2.18{\pm}0.76$ (T2), and $2.16{\pm}0.77$ (FLAIR). The smallest mean errors out of all the axes were in the x axis : 0.28-0.34 (1.5T) and 0.31-0.52 (3.0T). The smallest errors out of all the MRI sequences were in the T2 : 0.29-0.58 (1.5T) and 0.31-1.85 (3.0T). Conclusion : There was no interpersonal difference in running the Gamma $Plan^{(R)}$ to define coordinates. The errors of the 3.0T were greater than those of the 1.5T, and these errors were not of an acceptable level. The x coordinate error was the smallest and the z coordinate error was the greatest regardless of the MRI sequence. The T2 sequence was the most accurate sequence.

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer (원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과)

  • Kim, Woo-Chul;Kim, Hun-Jung;Park, Jeong-Hoon;Huh, Hyun-Do;Choi, Sang-Huoun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.28-35
    • /
    • 2011
  • Purpose: Recently, the use of radiosurgery as a local therapy in patients with early stage non-small cell lung cancer has become favored over surgical resection. To evaluate the efficacy of radiosurgery, we analyzed the results of stereotactic body radiosurgery in patients with primary or recurrent non-small cell lung cancer. Materials and Methods: We reviewed medical records retrospectively of total 24 patients (28 lesions) with non-small cell lung cancer (NSCLC) who received stereotactic body radiosurgery (SBRT) at Inha University Hospital. Among the 24 patients, 19 had primary NSCLC and five exhibited recurrent disease, with three at previously treated areas. Four patients with primary NSCLC received SBRT after conventional radiation therapy as a boost treatment. The initial stages were IA in 7, IB in 3, IIA in 2, IIB in 2, IIIA in 3, IIIB in 1, and IV in 6. The T stages at SBRT were T1 lesion in 13, T2 lesion in 12, and T3 lesion in 3. 6MV X-ray treatment was used for SBRT, and the prescribed dose was 15~60 Gy (median: 50 Gy) for PTV1 in 3~5 fractions. Median follow up time was 469 days. Results: The median GTV was 22.9 mL (range, 0.7 to 108.7 mL) and median PTV1 was 65.4 mL (range, 5.3 to 184.8 mL). The response rate at 3 months was complete response (CR) in 14 lesions, partial response (PR) in 11 lesions, and stable disease (SD) in 3 lesions, whereas the response rate at the time of the last follow up was CR in 13 lesions, PR in 9 lesions, SD in 2 lesions, and progressive disease (PD) in 4 lesions. Of the 10 patients in stage 1, one patient died due to pneumonia, and local failure was identified in one patient. Of the 10 patients in stages III-IV, three patients died, local and loco-regional failure was identified in one patient, and regional failure in 2 patients. Total local control rate was 85.8% (4/28). Local recurrence was recorded in three out of the eight lesions that received below biologically equivalent dose 100 $Gy_{10}$. Among 20 lesions that received above 100 $Gy_{10}$, only one lesion failed locally. There was a higher recurrence rate in patients with centrally located tumors and T2 or above staged tumors. Conclusion: SBRT using a CyberKnife was proven to be an effective treatment modality for early stage patients with NSCLC based on high local control rate without severe complications. SBRT above total 100 $Gy_{10}$ for peripheral T1 stage patients with NSCLC is recommended.

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC) (이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가)

  • Kim, Ae Ran;Seo, Jae-Hyuk;Shin, Hun-Joo;Park, Hyeong Wook;Lee, Ki Woong;Lee, Jae Choon;Kim, Shin-Wook;Kim, Ji Na;Park, Hyeli;Lee, Heui-Kwan;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.223-228
    • /
    • 2015
  • Double-focused micro-Multileaf Collimator (${\mu}MLC$) is able to create radiation fields having sharper dose gradients at the field edges than common MLC. Therefore, ${\mu}MLC$ has been used for the stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT). We evaluated the dosimetric characteristics of a doublefocused Dynamic-${\mu}MLC$ (DMLC) attached to the Elekta Synergy linear accelerator. For this study, the dosimetric parameters including, Percent Depth Dose (PDD), Leaf leakage and penumbra, have been measured by using of the radiochromic films (GafChromic EBT2), EDGE diode detector and three-dimensional water phantom. All datas were measured on 6 MV x-ray. As a result, The DMLC shows transmission below to 1% and because of double-focused construction of the DMLC, the penumbras of fields with DMLC are independent from the field sizes. In this paper, the resulting dosimetric evaluations proved the applicability of the DMLC attached to the Elekta Synergy linear accelerator.

Brain Metastases from Solid Tumors: an Institutional Study from South India

  • Ghosh, Saptarshi;Rao, Pamidimukkala Brahmananda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5401-5406
    • /
    • 2015
  • Background: Brain metastases are the most common intra-cranial neoplasms. The incidence is on a rise due to advanced imaging techniques. Aims: The objective of the study was to analyse the clinical and demographic profile of patients with brain metastases from primary solid tumors. Materials and Methods: This is a retrospective single institutional study covering 130 consecutive patients with brain metastases from January 2007 to August 2014. Results: Some 64.6% of the patients were females. The majority were in the sixth decade of life. The site of the primary tumor was the lungs in 50.8% of the cases. The overall median time from the diagnosis of the primary malignancy to detection of brain metastases was 21.4 months. Survival was found to be significantly improved in patients with solitary brain lesions when compared to patients with multiple brain metastases, and in patients undergoing surgical excision with or without cranial irradiation when compared to whole brain irradiation alone. The majority of the cases belonged to the recursive partitioning analysis class II group. Whole brain radiation therapy was delivered to 79% of the patients. Conclusions: Most of the patients with brain metastases in the study belonged to recursive partitioning analysis classes II or III, and hence had poor prognosis. Most of the patients in the Indian context either do not satisfy the indications for surgical excision or are incapable of bearing the high cost associated with stereotactic radiosurgery. Treatment should be tailored on an individual basis to all these patients.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF