• Title/Summary/Keyword: Stereotactic Body Radiotherapy

Search Result 52, Processing Time 0.03 seconds

Is higher dose always the right answer in stereotactic body radiation therapy for small hepatocellular carcinoma?

  • Lee, Kyung Hwa;Yu, Jeong Il;Park, Hee Chul;Park, Su Yeon;Shin, Jung Suk;Shin, Eun Hyuk;Cho, Sungkoo;Jung, Sang Hoon;Han, Young Yih;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose: This study was conducted to compare clinical outcomes and treatment-related toxicities after stereotactic body radiation therapy (SBRT) with two different dose regimens for small hepatocellular carcinomas (HCC) ${\leq}3cm$ in size. Materials and Methods: We retrospectively reviewed 44 patients with liver-confined HCC treated between 2009 and 2014 with SBRT. Total doses of 45 Gy (n = 10) or 60 Gy (n = 34) in 3 fractions were prescribed to the 95% isodose line covering 95% of the planning target volume. Rates of local control (LC), intrahepatic failure-free survival (IHFFS), distant metastasis-free survival (DMFS), and overall survival (OS) were calculated using the Kaplan-Meier method. Results: Median follow-up was 29 months (range, 8 to 64 months). Rates at 1 and 3 years were 97.7% and 95.0% for LC, 97.7% and 80.7% for OS, 76% and 40.5% for IHFFS, and 87.3% and 79.5% for DMFS. Five patients (11.4%) experienced degradation of albumin-bilirubin grade, 2 (4.5%) degradation of Child-Pugh score, and 4 (9.1%) grade 3 or greater laboratory abnormalities within 3 months after SBRT. No significant difference was seen in any oncological outcomes or treatment-related toxicities between the two dose regimens. Conclusions: SBRT was highly effective for local control without severe toxicities in patients with HCC smaller than 3 cm. The regimen of a total dose of 45 Gy in 3 fractions was comparable to 60 Gy in efficacy and safety of SBRT for small HCC.

Clinical significance of radiation-induced liver disease after stereotactic body radiation therapy for hepatocellular carcinoma

  • Jun, Baek Gyu;Kim, Young Don;Cheon, Gab Jin;Kim, Eun Seog;Jwa, Eunjin;Kim, Sang Gyune;Kim, Young Seok;Kim, Boo Sung;Jeong, Soung Won;Jang, Jae Young;Lee, Sae Hwan;Kim, Hong Soo
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1093-1102
    • /
    • 2018
  • Background/Aims: The aim of this study was to investigate parameters that predict radiation-induced liver disease (RILD) following stereotactic body radiotherapy (SBRT) in patients with hepatocellular carcinoma (HCC) and to identify the clinical significance of RILD. Methods: We retrospectively reviewed the medical records of 117 HCC patients who were treated by SBRT from March 2011 to February 2015. RILD was defined as elevated liver transaminases more than five times the upper normal limit or a worsening of Child-Pugh (CP) score by 2 within 3 months after SBRT. All patients were assessed at 1 month and every 3 months after SBRT. Results: Median follow-up was 22.5 months (range, 3 to 56) after SBRT. RILD was developed in 29 of the 117 patients (24.7%). On univariate analysis, significant predictive factors of RILD were pretreatment CP score (p < 0.001) and normal liver volume (p = 0.002). Multivariate analysis showed that CP score was a significant predictor of RILD (p < 0.001). The incidence of RILD increased above a CP score of 6 remarkably. The rate of recovery from RILD decreased significantly above a CP score of 8. Survival analysis showed that CP score was an independent prognostic factor of overall survival (p = 0.001). Conclusions: CP score is a significant factor to predict RILD in patients with chronic liver disease. RILD can be tolerated by patients with a CP score ${\leq}7$. However, careful monitoring of liver function is needed for patients with a CP score 7 after SBRT.

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Dosimetric Effects of Air Pocket during Magnetic Resonance-Guided Adaptive Radiation Therapy for Pancreatic Cancer

  • Jin, Hyeongmin;Kim, Dong-Yun;Park, Jong Min;Kang, Hyun-Cheol;Chie, Eui Kyu;An, Hyun Joon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART), an emerging technique, is used to address the change in anatomical structures, such as treatment target region, during the treatment period. However, the electron density map used for dose calculation differs from that for daily treatment, owing to the variation in organ location and, notably, air pockets. In this study, we evaluate the dosimetric effect of electron density override on air pockets during online ART for pancreatic cancer cases. Methods: Five pancreatic cancer patients, who were treated with MRgART at the Seoul National University Hospital, were enrolled in the study. Intensity modulated radiation therapy plans were generated for each patient with 60Co beams on a ViewrayTM system, with a 45 Gy prescription dose for stereotactic body radiation therapy. During the treatment, the electron density map was modified based on the daily MR image. We recalculated the dose distribution on the plan, and the dosimetric parameters were obtained from the dose volume histograms of the planning target volume (PTV) and organs at risk. Results: The average dose difference in the PTV was 0.86Gy, and the observed difference at the maximum dose was up to 2.07 Gy. The variation in air pockets during treatment resulted in an under- or overdose in the PTV. Conclusions: We recommend the re-contouring of the air pockets to deliver an accurate radiation dose to the target in MRgART, even though it is a time-consuming method.

Outcomes of stereotactic body radiotherapy for unresectable primary or recurrent cholangiocarcinoma

  • Jung, Da Hoon;Kim, Mi-Sook;Cho, Chul Koo;Yoo, Hyung Jun;Jang, Won Il;Seo, Young Seok;Paik, Eun Kyung;Kim, Kum Bae;Han, Chul Ju;Kim, Sang Bum
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: To report the results of stereotactic body radiotherapy (SBRT) for unresectable primary or recurrent cholangiocarcinoma. Materials and Methods: From January 2005 through August 2013, 58 patients with unresectable primary (n = 28) or recurrent (n = 30) cholangiocarcinoma treated by SBRT were retrospectively analyzed. The median prescribed dose was 45 Gy in 3 fractions (range, 15 to 60 Gy in 1-5 fractions). Patients were treated by SBRT only (n = 53) or EBRT + SBRT boost (n = 5). The median tumor volume was 40 mL (range, 5 to 1,287 mL). Results: The median follow-up duration was 10 months (range, 1 to 97 months). The 1-year, 2-year overall survival rates, and median survival were 45%, 20%, and 10 months, respectively. The median survival for primary group and recurrent group were 5 and 13 months, respectively. Local control rate at 1-year and 2-year were 85% and 72%, respectively. Disease progression-free survival rates at 1-year and 2-year were 26% and 23%, respectively. In univariate analysis, ECOG performance score (0-1 vs. 2-3), treatment volume (<50 vs. ${\geq}50mL$), and pre-SBRT CEA level (<5 vs. ${\geq}5ng/mL$) were significant in overall survival rate. In multivariate analysis, ECOG score (p = 0.037) and tumor volume (p = 0.030) were statistically significant. In the recurrent tumor group, patients with >12 months interval from surgery to recurrence showed statistically significant higher overall survival rate than those with ${\leq}12$ months (p = 0.026). Six patients (10%) experienced ${\geq}$grade 3 complications. Conclusion: SBRT can be considered as an effective local modality for unresectable primary or recurrent cholangiocarcinoma.

Evaluation of Treatment Outcomes of Early-Stage Endometrial Cancer Radiotherapy: A Single Center Experience

  • Demiral, S.;Beyzadeoglu, M.;Sager, O.;Dincoglan, F.;Uysal, B.;Gamsiz, H.;Akin, M.;Turker, T.;Dirican, B.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9599-9602
    • /
    • 2014
  • Background: Postoperative adjuvant radiotherapy (RT) in the management of early stage endometrial cancer (EC) is still controversial. Here we report our institutional experience with patients who received postoperative RT for stage I-II EC over a period of 35 years and assess potential predictors of local recurrence (LR), distant metastasis (DM), and overall survival (OS). Materials and Methods: A total of 188 patients undergoing postoperative RT for stage IA-II EC between 1977 and 2012 were evaluated. Some 96 received median 46 Gy whole pelvic radiotherapy (WPRT) (range: 40-60 Gy), 37 were given WPRT with vaginal cuff therapy (VCT), and 55 received only VCT either with brachytherapy (BT) or stereotactic body radiotherapy (SBRT). Chemotherapy was given to 5 patients with uterine papillary serous carcinoma (UPSC). Logistic regression analysis was used to assess the effect of clinicopathological factors on LR, DM, and OS. Results: Median follow-up time was 11 years (range: 1-35 years). At the time of analysis, 34 patients were not alive. Of the 15 patients with LR, 7 (46.7%) recurred in the vaginal stump, 5 (33.3%) in the pelvic region, and 3 (20%) in the paraaortic nodal region, while 12 had distant metastasis. UPSC histology (p=0.027), sole VCT (p=0.041), high histologic grade (p=0.034), and age ${\geq}71$ (p=0.04) were poor prognostic factors on univariate analysis. Conclusions: In our patients receiving radiotherapy for early-stage EC, grade III disease and age ${\geq}71$ were associated with shorter OS whereas UPSC histology was an independent predictor for both LR and DM.

Calculation of Dose Distribution for SBRT Patient Using Geant4 Simulation Code (Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산)

  • Kang, Jeongku;Lee, Jeongok;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.36-41
    • /
    • 2015
  • The Monte Carlo based dose calculation program for stereotactic body radiotherapy was developed in this study. The Geant4 toolkit widely used in the radiotherapy was used for this study. The photon energy spectrum of the medical linac studied in the previous research was applied for the patient dose calculations. The geometry of the radiation fields defined by multi-leaf collimators were taken into account in the PrimaryGeneratorAction class of the Geant4 code. The total of 8 fields were demonstrated in the patient dose calculations, where rotation matrix as a function of gantry angle was used for the determination of the source positions. The DicomHandler class converted the binary file format of the DICOM data containing the matrix number, pixel size, endian type, HU number, bit size, padding value and high bits order to the ASCII file format. The patient phantom was constructed using the converted ASCII file. The EGSnrc code was used to compare the calculation efficiency of the material data.

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients (RPM SystemTM을 이용한 호흡 관찰의 유용성 평가)

  • Park, hyun jun;Bae, sun myeong;Baek, Geum Mun;Kang, tae young;Seo, Dong Rin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose : The purpose of this study is to evaluate the variability of tumor motion and respiration pattern in lung cancer patients undergoing Stereotactic Body RadioTherapy(SBRT) by using On-Board imager (OBI) system and Real-time Position Management (RPM) System. Materials and Methods : This study population consisted of 60 lung cancer patient treated with stereotactic body radiotherapy (48 Gy / 4 fractions). Of these, 30 were treated with gating (group 1) and 30 without gating(group2): typically the patients whose tumors showed three-dimensional respiratory motion > 10 mm were selected for gating. 4-dimensional Computed Tomography (4DCT). Cone Beam CT (CBCT) and Fluoroscopy images were used to measure the tumor motion. RPM system was used to evaluate the variability of respiration pattern on SBRT for group1. Results : The mean difference of tumor motion among 4DCT, CBCT and Fluoroscopy images in the cranio-caudal direction was 2.3 mm in group 1, 2. The maximum difference was 12.5 mm in the group 1 and 8.5 mm in group 2. The number of treatment fractions that patient's respiration pattern was within Upper-Lower threshold on SBRT in group 2 was 31 fractions. A patient who exhibited the most unstable pattern exceeded 108 times in a fraction Conclusion : Although many patients in group 1 and 2 kept the reproducibility of tumor motion within 5 mm during their treatment, some patients exhibited variability of tumor motion in the CBCT and Fluoroscopy images. It was possible to improve the accuracy of dose delivery in SBRT without gating for lung cancer patient by using RPM system.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF