• Title/Summary/Keyword: Stereoscopic microscope

Search Result 66, Processing Time 0.03 seconds

Development of Stereoscopic Display System for Stereo Microscope

  • Kwon, Ki-Chul;Kim, Jung-Hoi;Kim, Nam;Choi, Jae-Kwang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.425-427
    • /
    • 2004
  • Many of the problems by using the microscope are related to the fact that the eyes of the surgeon must be continually fixed to the microscope eyepieces. In this paper, we describe a development of the stereoscopic monitoring system of the stereo microscope for reduced eyestrain or operator fatigue about the long time observations of the microscope. The system consists of the stereoscopic camera part, the stereoscopic image processor device and the polarized light stereoscopic monitor. The left and right images obtained form the two CCD cameras are the same as the eyepiece images. By use of the image processor, the polarized light stereoscopic monitor displayed a real-time stereo microscope images.

  • PDF

Use of Stereoscopic Microscope for Practice of Microsurgical Skill (미세수술 술기 연습을 위한 실체 현미경의 사용)

  • Song, Jeong-Hoon;Jeong, Eui-Cheol;Kwon, Sung-Tack
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.75-78
    • /
    • 2009
  • Purpose: Microsurgery is an essential technique in plastic and reconstructive surgery. However, microsurgical suturing and handling of the instrument are difficult for beginners, and who requires a steep learning curve. Therefore, methods for improving the technical skill are needed. The authors describe the value of a small stereoscopic microscope as a training tool. Materials and Methods: A small stereoscopic microscope was used to help improve the microsurgical skill. Monofilament 10-0 Nylon and a surgical rubber globe were used as a suture material and education material, respectively Result: Stereoscopic view of the operation field was obtained and basic microsurgical suture was possible. Conclusion: The stereoscopic microscope is an effective training tool for beginners of microsurgery with benefits in cost and usefulness in small place.

  • PDF

Dissection for rat hippocampus using high-definition stereoscopic microscope system (HD급 입체현미경시스템을 이용한 해마세포 적출)

  • Im, Yeong-Tae;Kim, Nam;Lee, Chan-Su;Lee, Gwon-Yeon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.367-368
    • /
    • 2007
  • Dissection of rat hippocampus using high-definition stereoscopic microscope system is demonstrated. Many surgical operation or animal anatomies are anatomized with stereoscopic microscope. With stereoscopic microscope system, the environments of operation is important factor to dissector. Lights, resolution of acquired stereo images, reflected on the liquid, colors and eye fatigue are fatal factors to dissector. We reduced reflections with two incident angle of lights at 45 degree and used a complementary color at the basement and reform the stereoscopic microsystem. Dissector has felt more comfortable after compensation and operation time is more continuous.

  • PDF

Multiple Vision Based Micromanipulation System for 3D-Shaped Micro Parts Assembly

  • Lee, Seok-Joo;Park, Gwi-Tae;Kim, Kyunghwan;Kim, Deok-Ho;Park, Jong-Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.103.5-103
    • /
    • 2001
  • This paper presents a visual feedback system that controls a micromanipulator using multiple microscopic vision information. The micromanipulation stations basically have optical microscope. However the single field-of-view of optical microscope essentially limits the workspace of the micromanipulator and low dept-of-field makes it difficult to handle 3D-shaped micro objects. The system consists of a stereoscopic microscope, three CCD cameras, the micromanipulator and personal computer. The use of stereoscopic microscope which has long working distance and high depth-of-field with selective field-of-view improves the recognizability of 3D-shaped micro objects and provides a method for overcoming several essential limitations in micromanipulation. Thus, visual feedback information is very important in handling micro objects for overcoming those limitations and provides a mean for the ...

  • PDF

Stereoscopic micro-PIV measurements of jet flow (미세제트 유동의 Stereoscopic micro-PIV측정)

  • Yu, Cheong-Hwan;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2007
  • Micro-PIV(particle image velocimetry) has been widely used to measure the velocity of micro flow. Although this micro-PIV method can give accurate 2D instantaneous velocity information of mea-surement plane, it cannot resolve the out of plane component of velocity vectors. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is useful to understand the physics of micro flow phenomena. In this study, we constructed stereoscopic micro-PIV(SMPIV) system and applied this method to the impinging micro jet flow. The results show that this method can produce accu-rate 3D reconstruction of micro jet flow.

Development of Stereoscopic Micro-PTV Method (Stereoscopic micro-PTV기법의 개발)

  • Yu, Cheong-Hwan;Kim, Hyoung-Bum
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.109-113
    • /
    • 2007
  • Micro-PIV is a well-known method for measurement of two- dimensional, two-component velocity in the microfluidic devices. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is helpful to understand the physics of micro flow phenomena. In this study, we developed new micro 3D measurement method by applying 2-frame PTV in stereoscopic micro system. In this study, we did the validation study of SMPTV by using the simulated flow model to verify the accuracy and the feasibility of measurement and compared with SMPIV method. The results showed that SMPTV provides better spatial resolution and measurement accuracy than SMPIV method.

  • PDF

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

In-Situ Observation of New Extra-Vascular Threadlike Structure of Mouse Using a Fluorescence Stereoscopic Microscope

  • Sung, Baeck-Kyoung;Lee, Ja-Woong;Lee, Byung-Cheon;Johng, Hyun-Min;Baik, Ku-Youn;Nam, Tae-Jeong;Park, Dae-Hun;Soh, Kyeong-Sun;Soh, Kwang-Sup
    • Journal of Pharmacopuncture
    • /
    • v.7 no.3
    • /
    • pp.73-76
    • /
    • 2004
  • We report the new threadlike structures outside the blood vessels of mice. For this, we developed an in-situ searching method of the structure by vital staining with the dye of acridine orange and using a fluorescent stereomicroscope designed specifically for this purpose. We consider that the newly found threadlike structure might be rediscovery of the extra-vascular Bonghan duct which was reported in 1963 by Bonghan Kim.

The Analysis of Conductive fibers for Smart Wear (스마트웨어 적용을 위한 전도성 소재분석)

  • Park, Yeong-Min;Jin, Sang-U;Jo, Gwang-Nyeon;Kim, Hong-Je;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.10a
    • /
    • pp.31-32
    • /
    • 2008
  • In this study, we have investigated a conductive fiber properties for smart wear. The effect of factors such as fiber length, denier, sewing method, washing on conductivity achieved was investigated and determined using stereoscopic microscope, SEM and LCR meter.

  • PDF

Cuclotogaster heterographus and Anaticola anseris(Mallophagh; Ischnocera): Collection fram Ciconia boyciana, Description and Observation with Scanning Electron Microscopy (황새의 이(蝨) Cuclotogaster heterographus와 Anaticola anseris의 주사전자현미경적관찰(走査電子顯微鏡的觀察))

  • Kang, Yung-bai;Byun, Si-yul
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.2
    • /
    • pp.227-236
    • /
    • 1984
  • A migratory bird, the white stork, Ciconia boyciana was captured from a pond in the Cheju Island on the 18th of December in 1982. The morphological characteristics were described as seen in the binocular stereoscopic microscope and the further fine structures were observed by means of the scanning electron microscope (Model; ISI-DS-130). The bird was examined for the ectoparasites at the Cheju Provincial Veterinary Research Laboratory. Two kinds of specimens were collected from the head and body feathers. The specimens were sent to the Institute of Veterinary Research in Anyang for the classification and identification. The specimens preserved in 70% ethyl alcohol were examined and identified as the fowl head-louse, Cuclotogaster heterographus and the slender goose-louse, Anaticola anseris both classified into Family Philopteridae, Ischnocera, Order Mallophaga.

  • PDF