• Title/Summary/Keyword: Stereomicroscope

Search Result 215, Processing Time 0.022 seconds

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

Effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia (시편 제작 방법이 지르코니아 코어와 비니어링 세라믹의 미세 인장결합강도에 미치는 영향)

  • Kim, Ki-Yeon;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.114-119
    • /
    • 2011
  • The aim of this study was to investigate effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia core. Materials and methods: Cylindrical Lava zirconia block (3M ESPE, Seefeld, Germany) was cut into discs using a diamond disc. After sintering, the core specimens were placed in an adjustable mold and veneered with Lava ceram (3M ESPE, Seefeld, Germany). The disc shaped specimen of group 1 was cut into microbars ($1{\times}1{\times}7\;mm^3$) using a low speed diamond disc under water cooling (n = 15). The specimen of group 2 was cut into microbars ($1.2{\times}1.2{\times}7\;mm^3$) in the same way. Whereafter the microbars were trimmed ($1{\times}1{\times}7\;mm^3$) using a thick diamond disc under water cooling (n = 15). The microtensile bond strength was tested in a microtensile tester (Instron 8848, $Instron^{(R)}$ Co., Norwood, USA). Fractured microtensile specimens were analyzed under a stereomicroscope (MZ6, Leica Microsystems GmbH, Wetzlar, Germany) at magnification ${\times}30$. Results: The microtensile bond strength of group 1 ($28.8{\pm}7.0\;MPa$) was significantly higher than group 2 ($11.0{\pm}33\;MPa$) (P=.00). Conclusion: It appears advisable to avoid the trimming action, especially high strength ceramic specimens.

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

INFLUENCE OF THREE DIFFERENT PREPARATION DESIGNS ON THE MARGINAL AND INTERNAL GAPS OF CEREC3 CAD/CAM INLAYS (세 가지 다른 인레이 와동 형태가 CEREC3 CAD/CAM의 변연 및 내면 간극에 미치는 영향)

  • Seo, Deog-Gyu;Yi, Young-Ah;Lee, Yoon;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • The aim of this study was to evaluate the marginal and internal gaps in CEREC3 CAD/CAM inlays of three different preparation designs. CEREC3 Inlays of three different preparation designs (n=10) were fabricated according to Group I-conventional functional cusp capping/shoulder preparation, Group II-horizontal reduction of cusps and Group III-complete reduction of cusps/shoulder preparation. After cementation of inlays. the bucco-lingual cross section was performed through the center of tooth. Cross section images of 20 magnifications were obtained through the stereomicroscope. The gaps were measured using the Leica application suite software at each reference point. Statistical analysis was performed using one-way ANOVA and Tukey's test (${\alpha}<0.05$). The marginal gaps ranged from 80.0 to $97.8{\mu}m$ for Group I, 42.0 to $194.8{\mu}m$ for Group II, 51.0 to $80.2{\mu}m$ for Group III. The internal gaps ranged from 90.5 to $304.1{\mu}m$ for Group I, 80.0 to $274.8{\mu}m$ for Group II, 79.7 to $296.7{\mu}m$ for Group III. The gaps of each group were the smallest on the margin and the largest on the horizontal wall. For the CEREC3 CAD/CAM inlays, the simplified designs (groups II and III) did not demonstrate superior results compared to the traditional cusp capping design (group I).

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.

Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials (Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.200-209
    • /
    • 2017
  • The aim of this study was to evaluate the shear bond strength (SBS) of three typical restorative materials - glass ionomer cement (GIC), resin-modified glass ionomer (RMGIC) and composite resin (CR) - to different pulp capping materials, i.e., Theracal $LC^{TM}$ (TLC), $Biodentine^{TM}$ (BD), and $ProRoot^{TM}$ white MTA (WMTA). 90 acrylic blocks with a center hole were prepared. The holes were completely filled with three pulp capping materials (TLC, BD, and WMTA), with 30 specimens per capping material. The samples were then randomly divided into 3 subgroups of 10 specimens each and were overlaid with GIC, RMGIC, or CR. A total 9 specimen groups were prepared. The SBS was assessed using a universal testing machine. Kruskal-Wallis test and Mann-Whitney's test were performed to compare the SBS among the subgroups (p < 0.05). After the SBS test, the fractured surfaces were examined under a stereomicroscope at a magnification of $25{\times}$. The highest and lowest SBS values were recorded for TLC-CR and TLC-GIC, respectively. With regard to the SBS to the three pulp capping materials, CR was found to be superior to RMGIC and GIC. BD showed a higher SBS compared to TLC and WMTA when used with GIC.

Shear Bond Strength and Microleakage of a New Self-etch Sealant Containing S-PRG filler (S-PRG 필러를 포함하는 치면열구전색제의 전단결합강도 및 미세누출)

  • An, Jinseon;Lee, Juhyun;Seo, Hyunwoo;Park, Howon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.347-353
    • /
    • 2016
  • The purpose of this study was to evaluate shear bond strength and microleakage of a new self-etch fissure sealant containing S-PRG filler (BeautiSealant). Fourty-five premolars were randomly divided into three groups: SEPBS group (Self-etching primer + BeautiSealant), AEBS group (Phosphoric acid etching + BeautiSealant), AECP group (Phosphoric acid etching + $Clinpro^{TM}$ sealant). For the shear bond strength test, microcylinders of fissure sealant were bonded to prepared buccal surfaces of teeth and shear bond strengths were measured by a universal testing machine. For the microleakage test, sealants were applicated on each occlusal fissure of teeth. All teeth surface were coated with finger nail varnish, with the exception of a 1.0 mm window around the sealant margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. SEPBS group demonstrated lower bond strength in comparison with that of AEBS and AECP groups (p < 0.05). However, no significant differences were observed between AEBS and AECP groups. There was no statistically significant difference in degree of microleakage among three groups.

High Prevalence of Haplorchis taichui, Phaneropsolus molenkampi, and Other Helminth Infections among People in Khammouane Province, Lao PDR

  • Chai, Jong-Yil;Han, Eun-Taek;Shin, Eun-Hee;Sohn, Woon-Mok;Yong, Tai-Soon;Eom, Keeseon S.;Min, Duk-Young;Um, Jin-Young;Park, Min-Sung;Hoang, Eui-Hyug;Phommasack, Bounlay;Insisiengmay, Bounnaloth;Lee, Soon-Hyung;Rim, Han-Jong
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.3
    • /
    • pp.243-247
    • /
    • 2009
  • The prevalence of liver and intestinal helminth infections, including Opisthorchis, Haplorchis, Phaneropsolus, hookworms, Enterobius, and Taenia, was surveyed in Khammouane province, Lao PDR. Fecal specimens were collected from 1,242 people (590 men and 652 women) in 3 Mekong riverside villages and were examined by the Kate-Katz thick smear technique. The overall helminth egg positive rate was 81.1%. The positive rate for small trematode eggs, including Opisthorchis viverrini, heterophyids, and lecithodendriids, was 81.1% and the positive rate for hookworms was 6.7%. To obtain adult worms, 35 people who were positive for small trematode eggs were treated with 20-30 mg/kg praziquantel and 10-15 mg/kg pyrantel pamoate, and then purged. Diarrheic stools were collected from 33 of these people and searched for helminth parasites using a stereomicroscope. Mixed infections with various helminths (Haplorchis taichui, Haplorchis yokogawai, Prosthodendrium molenkampi, Phaneropsolus bonnei, echinostomes, hookworms, Trichostrongylus spp., Trichuris trichiura, Enterobius vermicularis, and/or Taenia saginata) were found. The total number of helminth specimens collected was 20,907 (approximately 634 per person). The most common species was H. taichui, followed by P. molenkampi, 0. viverrini, P. bonnei, E. vermicularis, hookworms, and Trichostrongylus spp. These results show that diverse species of intestinal nematodes, trematodes, and cestodes are infecting humans in Khammouane province, Lao PDR.

Effect of $Ca^{++}$ Ionophore and $Ca^{++}$-Channel Blocker on the Mouse Oocyte Maturation (생쥐 난자성숙에 미치는 $Ca^{++}$ Ionophore와 $Ca^{++}$ Channel Blocker의 영향)

  • Bae, In-Ha;Kim, Hyun-Sook;Kim, Moon-Kyoo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.2
    • /
    • pp.105-116
    • /
    • 1992
  • The present study was examined to clarify the role of calcium ion as a factor for the maturation of mouse oocytes. Follicles and cumulus-enclosed oocytes were isolated with two sharp needles under a stereomicroscope from female mouse (ICR) ovaries which were treated PMSG 5 IU 45-46 hours previously. Isolated follicles and cumulus-enclosed oocytes were cultured for 14-16 hours in an organ culture system at $37^{\circ}C$, 5% $CO_2$ in air and 100% humudified in incubator. MHBS was the basic medium used from which A23187, verapamil, $NiCl_{2.}$ $6H_2O$ and $LaCl_{3.}$ $7H_2O$ were added depending on the experimental groups. In follicle- or cumulus-enclosed oocytes wre cultured in these differently treated media. Following results were obtained from the present study. 1. The calcium ionophore A23187 directly or indirectly seems to stimulate GVBD of follicle-enclosed mouse oocytes. Increasing concentration of ionophore A23187 1ed to an increase in oocytes degeneration from the cumulus-enclosed mouse oocytes. 2. The organic $Ca^{++}$ channel blocker, verapamil does not induce GVBD of follicle-enclosed mouse oocytes. Specially, higher dose of 1 mM verapamil induced GVBD of follicle-enclosed mouse oocytes. However, cytoplasm of GVBD oocytes in 1 mM verapamil treated groups appeared shrunk. In the cumulus-enclosed oocytes, polar body formation was reduced in verapamil treated groups and degeneration increased. Verapamil inhibit oocyte maturation (polar body formation). 3. The $Ca^{++}$ inhibitor, Nickel ($NiCl_{2.}$ $6H_2O$) inhibits maturation of the follicle-enclosed oocytes. In the cumulus-enclosed oocytes the progression to MII (PB formation) was reduced and degeneration of mouse oocytes increased as the concentration of $Ni^{++}$ increase. The results indicates that nickel act as an inhibitor of calcium. 4. The $Ca^{++}$ inhibitors, Lanthanum ($LaCl_{3.}$ $7H_2O$) has shown different effect from that of nickel. In follicle-enclosed oocytes, 0.01mM lanthanum induced maturation of mouse oocytes. Polar body formation was reduced in the cumulus-enclosed oocytes all lanthanum treated group.

  • PDF

Microleakage Assessment of a Pozzolan Cement-based Mineral Trioxide Aggregate Root Canal Sealer (포졸란 시멘트를 기반으로 하는 근관전색제의 치근단부 미세누출 평가)

  • Kim, Mijun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • This study aimed to assess microleakage of Endoseal MTA when it is used as a root canal sealer and a root canal filling material compared with conventional endodontic treatment materials Forty-two mature human permanent teeth with a single root canal were divided randomly into three experimental groups (n = 10) and two control groups (n = 6). Group A was obturated with AH $plus^{(R)}$ and gutta-percha (GP). Group E1 was obturated with Endoseal MTA and GP. Group E2 was obturated with Endoseal MTA only. The positive control group was obturated with GP only and the negative control group was obturated in the same way as the experimental groups. The samples were kept in saline solution for 24 hours and were immersed in 0.2% rhodamine B dye solution for 24 hours. Then the samples were split longitudinally and the micoleakage was assessed under a stereomicroscope. Complete microleakage was detected in all positive control group samples, whereas no microleakage was detected in the negative control group. There was no statistically significant difference between the experimental groups in the Kruskal-Wallis test. These results suggest that Endoseal MTA has potential use as a root canal sealer and a root canal filling material.