• 제목/요약/키워드: Stereo Camera Calibration

검색결과 105건 처리시간 0.024초

정밀한 영상 계측을 위한 스테레오 카메라의 오차 보정시스템 (Depth error calibration of stereo cameras for accurate instrumentation in objects)

  • 김종만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2313-2316
    • /
    • 2004
  • Accurate calibration effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount and showed the variable experiments for accurate effects.

  • PDF

체커보드의 유형에 따른 스테레오 카메라 캘리브레이션의 정확도 비교 (Comparison of the Accuracy of Stereo Camera Calibration According to the Types of Checkerboards)

  • 김의명;권상일
    • 한국측량학회지
    • /
    • 제38권6호
    • /
    • pp.511-519
    • /
    • 2020
  • 카메라 캘리브레이션을 위해 일반적으로 체커보드를 이용하여 주점, 초점거리, 렌즈 왜곡을 결정한다. 체커보드는 평면 형태와 3차원 형태가 있으며 체커보드의 크기, 타겟의 배치와 타겟점의 개수에 따라 카메라 캘리브레이션 매개변수에 영향을 미친다. 본 연구에서는 스테레오 카메라 캘리브레이션을 위해 체커보드의 유형에 따른 정확도를 검사점을 이용하여 비교하였으며 이를 통해 가장 성능이 우수한 체커보드를 제안하는 것을 목적으로 하였다. 평면 형태의 크기가 큰 체커보드는 검사점과의 비교를 통해서 비교적 높은 정확도를 나타내었다. 그러나 체커보드의 크기로 인하여 이동과 회전이 불편하였고 스테레오 카메라에서 타겟점이 모두 나타날 수 있도록 촬영하는 것이 어려운 단점이 있었다. 평면 형태의 작은 크기로 제작된 체커보드는 이동 및 회전이 편리하지만 가장 낮은 3차원 정확도를 나타내었다. 높이 값이 있는 타겟을 부착한 체커보드는 타겟점의 3차원 좌표를 카메라 캘리브레이션을 위해서 관측장비를 이용하여 결정해야 하는 번거로움이 있었지만 크기가 작아 이동과 회전이 편리하였고 가장 높은 3차원 정확도를 나타내었다.

배전 선로의 열화 진단을 위한 복합 카메라 보정기법 (A Composite Camera Calibration Technique for Thermal Deterioration Diagnosis of Power Distribution Line)

  • 정하형;박진하;유준
    • 제어로봇시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a composite camera calibration method to determine thermal degradation of power distribution equipment by combining an infrared (IR) camera and a color camera. A calibration jig was first constructed to match the properties of the two cameras. Our calibration and visualization techniques allow for the display of two images, one from the color camera and the other from the IR camera with different field of views (FOVs), on the screen at the same time. To confirm its validity, several case studies have been developed to analyze thermal deterioration limits of indoor and outdoor power distribution facilities.

화상처리기법을 이용한 판재의 변형률 측정(II) (Measurement of Strain of Sheet Metal by Image Processing (II))

  • 정재윤;황창원;허만성;김낙수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 추계학술대회논문집
    • /
    • pp.147-152
    • /
    • 1997
  • This paper presents a method for measuring and analyzing strains in sheet metal forming by stereo vision system. A better understanding and evaluation of the formability can be achieved by analyzing stain distribution in deformed sheet metals. By means of image processing technique, it is possible to get strain distribution efficiently. For measuring strain automatically and accurately, algorithms for camera calibration, grid detection, stereo matching and strain analysis has been developed and verified by experiments with GUI(Graphic User Interface).

  • PDF

동영상 정보의 계측정보 전송을 위한 비선형 스테레오 카메라의 오차 보정 (Depth error calibration of maladjusted stereo cameras for translation of instrumented image information in dynamic objects)

  • 김종만;김영민;황종선;임병현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.109-114
    • /
    • 2003
  • Depth error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with various experimental results.

  • PDF

스테레오 영상을 이용한 자기보정 및 3차원 형상 구현 (3D Reconstruction and Self-calibration based on Binocular Stereo Vision)

  • 후영영;정경석
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.3856-3863
    • /
    • 2012
  • 스테레오 영상으로부터 3차원 형상을 구현함에 있어 사용자의 개입을 최소로 필요로 하는 기법을 개발하였다. 형상구현은 특정 기하학 그룹을 평가하는 3단계로 이루어진다. 1단계는 영상에 존재하는 epipolar 기하 평가로 각 영상에서의 특정점들을 일치시킨다. 2단계는 소실점 방법을 이용하여 투영공간에서 특정평면을 찾는 affine 기하 평가이다. 3단계에서는 카메라의 자기보정을 포함하며 3차원 모델이 얻어질 수 있는 계량 기하 변수를 구한다. 이 방법의 장점은 형상구현을 위해 스테레오 영상을 보정할 필요가 없는 것으로, 그 구현가능성을 실증하였다.

정밀 켈리브레이션 정합을 위한 화상측징계 (The Image Measuring System for accurate calibration-matching in objects)

  • 김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.357-358
    • /
    • 2006
  • Accurate calibration matching for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of Intra parameter is calibrated with known points, such error can be compensated in some amount and showed the variable experiments for accurate effects.

  • PDF

젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발(II) - 스테레오 영상을 이용한 체위 분석 - (Development of Computer Vision System for Individual Recognition and Feature Information of Cow (II) - Analysis of body parameters using stereo image -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.65-76
    • /
    • 2003
  • The analysis of cow body parameters is important to provide some useful information fur cow management and cow evaluation. Present methods give many stresses to cows because they are invasive and constrain cow postures during measurement of body parameters. This study was conducted to develop the stereo vision system fur non-invasive analysis of cow body features. Body feature parameters of 16 heads at two farms(A, B) were measured using scales and nineteen stereo images of them with walking postures were captured under outdoor illumination. In this study, the camera calibration and inverse perspective transformation technique was established fer the stereo vision system. Two calibration results were presented for farm A and fm B, respectively because setup distances from camera to cow were 510 cm at farm A and 630cm at farm B. Calibration error values fer the stereo vision system were within 2 cm for farm A and less than 4.9 cm for farm B. Eleven feature points of cow body were extracted on stereo images interactively and five assistant points were determined by computer program. 3D world coordinates for these 15 points were calculated by computer program and also used for calculation of cow body parameters such as withers height. pelvic arch height. body length. slope body length. chest depth and chest width. Measured errors for body parameters were less than 10% for most cows. For a few cow. measured errors for slope body length and chest width were more than 10% due to searching errors fer their feature points at inside-body positions. Equation for chest girth estimated by chest depth and chest width was presented. Maximum of estimated error fur chest girth was within 10% of real values and mean value of estimated error was 8.2cm. The analysis of cow body parameters using stereo vision system were successful although body shape on the binocular stereo image was distorted due to cow movements.

단일카메라 전방향 스테레오 비전 시스템을 이용한 거리측정 (Depth Measurement using an Omnidirectional Stereo Vision System with a Single Camera)

  • 이수영;김순철
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.955-959
    • /
    • 2013
  • It is possible to obtain an omnidirectional stereo image via a single camera by using a catadioptric approach with a convex mirror and concave lens. In order to measure three-dimensional distance using the imaging system, the optical parameters of the system are required. In this paper, a calibration procedure to extract the parameters of the imaging system is described. Based on the parameters, experiments are carried out to verify the performance of the three-dimensional distance measurement of a single camera omnidirectional stereo imaging system.

Trinocular Vision System을 이용한 물체 자세정보 인식 향상방안 (A Study on the Improvement of Pose Information of Objects by Using Trinocular Vision System)

  • 김종형;장경재;권혁동
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.223-229
    • /
    • 2017
  • Recently, robotic bin-picking tasks have drawn considerable attention, because flexibility is required in robotic assembly tasks. Generally, stereo camera systems have been used widely for robotic bin-picking, but these have two limitations: First, computational burden for solving correspondence problem on stereo images increases calculation time. Second, errors in image processing and camera calibration reduce accuracy. Moreover, the errors in robot kinematic parameters directly affect robot gripping. In this paper, we propose a method of correcting the bin-picking error by using trinocular vision system which consists of two stereo cameras andone hand-eye camera. First, the two stereo cameras, with wide viewing angle, measure object's pose roughly. Then, the 3rd hand-eye camera approaches the object, and corrects the previous measurement of the stereo camera system. Experimental results show usefulness of the proposed method.