• Title/Summary/Keyword: Stereo Camera Calibration

Search Result 105, Processing Time 0.036 seconds

Depth error calibration of stereo cameras for accurate instrumentation in objects (정밀한 영상 계측을 위한 스테레오 카메라의 오차 보정시스템)

  • Kim, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2313-2316
    • /
    • 2004
  • Accurate calibration effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount and showed the variable experiments for accurate effects.

  • PDF

Comparison of the Accuracy of Stereo Camera Calibration According to the Types of Checkerboards (체커보드의 유형에 따른 스테레오 카메라 캘리브레이션의 정확도 비교)

  • Kim, Eui Myoung;Kwon, Sang Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.511-519
    • /
    • 2020
  • For camera calibration, a checkerboard is generally used to determine the principal point, focal length, and lens distortions. The checkerboard has a planar and three-dimensional shape, and camera calibration parameters are affected by the size of the checkerboard, the placement of the target, and the number of target points. In this study, the accuracies of the types of checkerboards were compared using checkpoints for stereo camera calibration, and the purpose of this study was to propose the best performance checkerboard. The checkerboard with large flat shape showed comparatively high accuracy through comparison with the check points. However, due to the size of the checkerboard, it was inconvenient to move and rotate, and there was a disadvantage in that it was difficult to shoot so that the target points could all appear in the stereo camera. The checkerboard, which was manufactured in a small size in a flat shape, was easy to move and rotate but had the lowest three-dimensional accuracy. The checkerboard with targets with height values had the hassle of having to determine the three-dimensional coordinates of the target points by using observation equipment for camera calibration, but it was small in size, convenient to move and rotate, and showed the highest three-dimensional accuracy.

A Composite Camera Calibration Technique for Thermal Deterioration Diagnosis of Power Distribution Line (배전 선로의 열화 진단을 위한 복합 카메라 보정기법)

  • Jung, Ha-Hyoung;Park, Jin-ha;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a composite camera calibration method to determine thermal degradation of power distribution equipment by combining an infrared (IR) camera and a color camera. A calibration jig was first constructed to match the properties of the two cameras. Our calibration and visualization techniques allow for the display of two images, one from the color camera and the other from the IR camera with different field of views (FOVs), on the screen at the same time. To confirm its validity, several case studies have been developed to analyze thermal deterioration limits of indoor and outdoor power distribution facilities.

Measurement of Strain of Sheet Metal by Image Processing (II) (화상처리기법을 이용한 판재의 변형률 측정(II))

  • 정재윤;황창원;허만성;김낙수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.147-152
    • /
    • 1997
  • This paper presents a method for measuring and analyzing strains in sheet metal forming by stereo vision system. A better understanding and evaluation of the formability can be achieved by analyzing stain distribution in deformed sheet metals. By means of image processing technique, it is possible to get strain distribution efficiently. For measuring strain automatically and accurately, algorithms for camera calibration, grid detection, stereo matching and strain analysis has been developed and verified by experiments with GUI(Graphic User Interface).

  • PDF

Depth error calibration of maladjusted stereo cameras for translation of instrumented image information in dynamic objects (동영상 정보의 계측정보 전송을 위한 비선형 스테레오 카메라의 오차 보정)

  • Kim, Jong-Man;Kim, Yeong-Min;Hwang, Jong-Sun;Lim, Byung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.109-114
    • /
    • 2003
  • Depth error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with various experimental results.

  • PDF

3D Reconstruction and Self-calibration based on Binocular Stereo Vision (스테레오 영상을 이용한 자기보정 및 3차원 형상 구현)

  • Hou, Rongrong;Jeong, Kyung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3856-3863
    • /
    • 2012
  • A 3D reconstruction technique from stereo images that requires minimal intervention from the user has been developed. The reconstruction problem consists of three steps of estimating specific geometry groups. The first step is estimating the epipolar geometry that exists between the stereo image pairs which includes feature matching in both images. The second is estimating the affine geometry, a process to find a special plane in the projective space by means of vanishing points. The third step, which includes camera self-calibration, is obtaining a metric geometry from which a 3D model of the scene could be obtained. The major advantage of this method is that the stereo images do not need to be calibrated for reconstruction. The results of camera calibration and reconstruction have shown the possibility of obtaining a 3D model directly from features in the images.

The Image Measuring System for accurate calibration-matching in objects (정밀 켈리브레이션 정합을 위한 화상측징계)

  • Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.357-358
    • /
    • 2006
  • Accurate calibration matching for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of Intra parameter is calibrated with known points, such error can be compensated in some amount and showed the variable experiments for accurate effects.

  • PDF

Development of Computer Vision System for Individual Recognition and Feature Information of Cow (II) - Analysis of body parameters using stereo image - (젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발(II) - 스테레오 영상을 이용한 체위 분석 -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-76
    • /
    • 2003
  • The analysis of cow body parameters is important to provide some useful information fur cow management and cow evaluation. Present methods give many stresses to cows because they are invasive and constrain cow postures during measurement of body parameters. This study was conducted to develop the stereo vision system fur non-invasive analysis of cow body features. Body feature parameters of 16 heads at two farms(A, B) were measured using scales and nineteen stereo images of them with walking postures were captured under outdoor illumination. In this study, the camera calibration and inverse perspective transformation technique was established fer the stereo vision system. Two calibration results were presented for farm A and fm B, respectively because setup distances from camera to cow were 510 cm at farm A and 630cm at farm B. Calibration error values fer the stereo vision system were within 2 cm for farm A and less than 4.9 cm for farm B. Eleven feature points of cow body were extracted on stereo images interactively and five assistant points were determined by computer program. 3D world coordinates for these 15 points were calculated by computer program and also used for calculation of cow body parameters such as withers height. pelvic arch height. body length. slope body length. chest depth and chest width. Measured errors for body parameters were less than 10% for most cows. For a few cow. measured errors for slope body length and chest width were more than 10% due to searching errors fer their feature points at inside-body positions. Equation for chest girth estimated by chest depth and chest width was presented. Maximum of estimated error fur chest girth was within 10% of real values and mean value of estimated error was 8.2cm. The analysis of cow body parameters using stereo vision system were successful although body shape on the binocular stereo image was distorted due to cow movements.

Depth Measurement using an Omnidirectional Stereo Vision System with a Single Camera (단일카메라 전방향 스테레오 비전 시스템을 이용한 거리측정)

  • Yi, Soo-Yeong;Kim, Soon-Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.955-959
    • /
    • 2013
  • It is possible to obtain an omnidirectional stereo image via a single camera by using a catadioptric approach with a convex mirror and concave lens. In order to measure three-dimensional distance using the imaging system, the optical parameters of the system are required. In this paper, a calibration procedure to extract the parameters of the imaging system is described. Based on the parameters, experiments are carried out to verify the performance of the three-dimensional distance measurement of a single camera omnidirectional stereo imaging system.

A Study on the Improvement of Pose Information of Objects by Using Trinocular Vision System (Trinocular Vision System을 이용한 물체 자세정보 인식 향상방안)

  • Kim, Jong Hyeong;Jang, Kyoungjae;Kwon, Hyuk-dong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.223-229
    • /
    • 2017
  • Recently, robotic bin-picking tasks have drawn considerable attention, because flexibility is required in robotic assembly tasks. Generally, stereo camera systems have been used widely for robotic bin-picking, but these have two limitations: First, computational burden for solving correspondence problem on stereo images increases calculation time. Second, errors in image processing and camera calibration reduce accuracy. Moreover, the errors in robot kinematic parameters directly affect robot gripping. In this paper, we propose a method of correcting the bin-picking error by using trinocular vision system which consists of two stereo cameras andone hand-eye camera. First, the two stereo cameras, with wide viewing angle, measure object's pose roughly. Then, the 3rd hand-eye camera approaches the object, and corrects the previous measurement of the stereo camera system. Experimental results show usefulness of the proposed method.