• Title/Summary/Keyword: Stepping motor Micro-Processor

Search Result 7, Processing Time 0.022 seconds

DEVELOPMENT OF X-Y PLANE DRIVING CONTROL SYSTEM BY STEPPING MOTOR (스텝 모터에 의한 X-Y 평면 구동 제어 시스템 개발)

  • Lee, S.Y.;Kim, B.H.;Park, S.D.;Kim, H.C.;Kim, W.C.;Hong, I.S.;Woo, C.H.;Oh, B.W.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2166-2168
    • /
    • 1998
  • A PWM inverter using power FET is developed to switch the excitation current of 5 phase hybrid stepping motor for the use of driving X, Y table. A micro processor based controller is also developed to control the excitation current switching of X, Y axis stepping motor as well as synchronizing operation of Z-axis servo motor. The developed driving control system is applied to the industrial embroidery sewing machine.

  • PDF

The Development of Clutch Control for Manual Transmission Vehicle based on Stepping Motor (스탭핑 모터에 의한 수동변속기 차량의 클러치 제어 개발에 관한 연구)

  • Park, Young-Kug;Park, Joon-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3849-3855
    • /
    • 2012
  • This paper describes a control algorithm and test results of an automated manual transmission clutch actuated by a stepping motor. The control algorithm extracts driver's demand from CAN signals and decides the exact timing to engage or disengage the clutch based on the demand. A pulse signal is generated to drive the clutch and the travel of the clutch can be calculated by accumulating the pulse signal. An auto code generation method was introduced in implementing the control logic to the micro-processor of the prototype controller and a series of basic tests were carried out to validate its performance.

Research on Development of a Wide Range Velocity Control Method of Small Size DC Motor for Portable Drug Delivery System

  • Lee, Dong-Joon;Lim, Yang-Ho;Kim, Jang-Hwan;Shin, Chan-Soo;Kim, Hee-Chan;Choi, Soo-Bong;Lee, Hong-Gyu
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.22-24
    • /
    • 1996
  • Small size DC motor control method for portable drug delivery system has been developed to be used for the actuator of insulins pump. The control method gives the controllabilities both in high speed(40-50 revolution per second(rps)) DC motor drive and also in low speed(0.5-1rps). In low speed mode DC motor is controlled to act like stepping motor and in high speed to optimize power consumption. To control both mode modified bang bang control is suggested. Using this method small size DC motor(spec.) speed is controlled from 0.2 rps to 50 rps. Experimental setup is developed using micro-processor(PIC16C73, Micro Chips co., USA), motor turns checking circuitry, small size DC motor for pager(SM1012, Samhong co., Korea) and gear box. Results from experiment meet need for vailable load condition which is require for portable drug delivery system.

  • PDF

Development of Directional Digital Hearing Aid Performance Testing System (지향성 디지털 보청기의 성능 검사 장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.411-414
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-like the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

Development of Directional Digital Hearing Aid Performance Testing System (지향성 보청기 성능 검사 장치 개발)

  • Jang, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.81-88
    • /
    • 2006
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-like the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to respond to receiving sound. The experimental results were compared with those of a boundary element method program for verification. The diameter of the directivity testing device was 2 m and the micro-mouse was precisely controlled by PICBASIC micro processor.

Development of Directional Digital Hearing Aid Performance Testing System (지향성 보청기 성능 검사 장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.469-474
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-1ike the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The experimental results were compared with a boundary element method program for verification. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

Development of the Automatic Page Passing Device (자동페이지 넘김장치의 개발)

  • 이형찬;서진석
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 2002
  • In this study, we deal with the system design and development of the automatic page passing machine. In order to turn pages without injury of a book or a musical note, we used an inhalation motor. Also, when we turn over pages. the successive actions of fixation and inhalation are embodied by motors which are operated by a microprocessor. In traditional products. some limited pages must be fixed into the Turning Bar in advance. On the contrary, proposed equipment is able to turn over the pages of a book without laying the groundwork. Experimental results using produced facilities are presented to demonstrate the efficacy of the proposed equipment.

  • PDF