• Title/Summary/Keyword: Stepping Point

Search Result 57, Processing Time 0.028 seconds

Differential effect of electroacupuncture analgesia depending on the point selection in a rat model of CFA-induced arthritis (CFA로 유도한 관절염에서 선혈(選穴)에 따른 전침(電鍼)의 진통효과 차이)

  • Yang, Bum-Sik;Koo, Sung-Tae;Kim, Kyoung-Sik;Sohn, In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.95-108
    • /
    • 2005
  • Objective : In the present study, the effect of electroacupuncture (EA) applied to several acupoints and non-acupoint in CFA-induced knee arthritis was examined. Methods : A common source of persistent pain in humans is arthritis. Arthritis was induced by injection of CFA $125\;{\mu}l$ into knee joint cavity under enflurane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful knee. EA was applied to either of $LR_2,\;LI_4$, or non-acupoint on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next 4 h. Results : EA applied to $LR_2$ point produced a significant improvement of stepping force of the affected foot lasting for at least 2 h. However, neigher $LI_4$ point nor non-point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effect on CFA-induced knee arthritic pain model could not be mimicked by EA applied to a point, $LI_4$ or non-acupoint. In addition, both NO production and iNOS protein expression increased by arthritis were suppressed by EA applied to $LR_2$ point. Conclusion : These data suggest that EA produces a potent analgesic effect in the rat model of CFA-induced knee arthritis. This analgesic effect is produced by applying EA to an acupoint at opposite side from the painful area in a stimulus point-specific way.

  • PDF

Effect of Electroacupuncture Applied to the Won Point and Rak Point in the Rat Model of Ankle Sprain Pain (원락(原絡) 배혈(配穴) 전침 자극이 백서의 족과 염좌(捻挫) 통증에 미치는 영향(影響))

  • Kim, Sun-Young;Koo, Sung-Tae;Kim, Kyoung-Sik;Sohn, In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.7-21
    • /
    • 2005
  • Objectives : In the present study, the effect of electroacupuncture (EA) applied to SI6 and won-rak point on the ankle sprain model was examined. A common source of persistent pain in humans is the lateral ankle sprain. Methods : To model this condition, the rat's right ankle was bent repeatedly, overextending lateral ligaments, for 4 min under enflurane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful ankle. EA was applied to the several acupuncture point on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force and Paw volume were Periodically conducted during the next 4 h and 18 h respectively. Results : EA applied to $SI_6$ with won-rak point produced more powerful improvement of stepping force of the sprained foot than to $SI_6$ alone lasting for at least 4 h. However, neigher $KI_4$ point nor $BL_{64}$ point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effort on the ankle sprain pain model could not be mimicked by EA applied to $KI_4$ or $BL_{64}$. In addition, EA applied to $SI_6$ with won-rak combination point showed inhibitory effect on the paw edema induced by ankle sprain. Also, COX-2 protein expression increased by ankle sprain were suppressed by the EA stimulation. Conclusion : These data suggest that EA with won-rak combination point produces a more potent analgesic effect on the ankle sprain pain model in the rat and that EA with won-rak combination point induced anti-inflammatory effect through the suppression of COX-2 protein expression.

  • PDF

Development of the disturbance observer for micro-stepping X-Y stage (마이크로 스텝핑 평판 스테이지의 외란 예측기의 개발)

  • Kim Jung-Han
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.23-31
    • /
    • 2005
  • The purpose of this study is to design a disturbance observer for a micro-stepping stage to eliminate the disturbances from cables, friction, mass unbalance of the moving part, etc. The disturbance observer is designed for air-floating X-Y precision micro-stepping X-Y stage which widely used in stepper machine or semiconductor manufacturing systems. The micro-stepping X-Y stage has a weak point of the variation of characteristics with position locations, which caused by various disturbances. In this study, it will be described that a simple and high throughput disturbance observer algorithm improves the dynamic error and settling time of the micro-stepping stage.

Effect of Acupuncture applied to Hand Yang Meridian on the Rat Model of Ankle Sprain Pain (수양경(手陽經) 경혈(經穴) 자침(刺鍼)이 백서(白鼠)의 족과 염좌(捻挫) 통증(痛症)에 미치는 영향(影響))

  • Kim, Il;An, Sung-Hun;Koo, Sung-Tae;Kim, Sun-Young;Kim, Kyung-Sik;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.69-82
    • /
    • 2004
  • Objectives : In the present study, the effect of electroacupuncture (EA) applied to hand yang meridian on the ankle sprain model was examined. Methods & Results : A common source of persistent pain in humans is the lateral ankle sprain. To model this condition, the rat's right ankle was bent repeatedly, overextending lateral ligaments, for 4 min under halothane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful ankle. EA was applied to the several acupuncture point on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next 4 h. EA applied to SI-6 point produced a significant improvement of stepping force of the sprained foot lasting for at least 2 h. However, neigher LI-4 point nor TE-3 point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effect on the ankle sprain pain model could not be mimicked by EA applied to a nearby point, LI-4 or TE-3. The analgesic effect of EA applied to SI-6 was more powerful when EA was applied by low-frequency and high-intensity stimulation. In addition, this effect need to be stimulated more than 15 min. Conclusions : These data suggest that EA produces a potent analgesic effect on the ankle sprain pain model in the rat. This analgesic effect is produced by applying EA to a Tae-Yang meridian at opposite side from the painful area in a stimulus point-specific way.

  • PDF

Electroacupuncture Analgesia on the Arthritic Pain in Two Different Models in Rats (백서의 두 종류 관절염 모델에서 통증에 대한 전침의 진통 효과)

  • Moon, Sang-don;Lim, Kyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.2
    • /
    • pp.138-151
    • /
    • 2003
  • Although the use of acupuncture for pain has increased in recent years, the mechanisms of acupuncture analgesia (AA) remains obscure. The lack of suitable experimental animal models for persistent pain, which show clear AA, has been the major stumbling block in the investigation of the physiological mechanisms of AA. In the present study, we test AA in two knee arthritis model induced by injection of CFA or carrageenan as a chronic pain model. After induction of arthritis, the rat subsequently showed a reduced stepping force of the affected limb for the next several days. Electroacupuncture (EA) was applied to an acupuncture point each on the contralateral forelimb for 30 minutes under enflurane anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next several hours. EA produced a significant improvement of stepping force of the foot lasting for at least 2 hours when applied to LR2 In CFA model, and applied to ST36 in carrageenan model, but both points did not produce any significant effects in each other model. These data suggest that EA produce analgesic effect in knee arthritic pain and the analgesic effect is specific to the acupuncture point.

  • PDF

Preconditioned Multistage time stepping for the Multigrid Navier-Stokes Solver (다중 격자 Navier-Stokes 해석을 위한 예조건화된 다단계 시간 전진 기법)

  • Kim Yoonsik;Kwon Jang Hyuk;Choi Yun Ho;Lee Seungsoo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.59-64
    • /
    • 2002
  • In this paper, the preconditioned multistage time stepping methods which are popular multigrid smoothers is implemented for the compressible Navier-Stokes calculation with full-coarsening multigrid method. The convergence characteristic of the point-Jacobi and Alternating direction line Jacobi(DDADI) preconditioners are studied. The performance of 2nd order upwind numerical fluxes such as 2nd order upwind TVD scheme and MUSCL-type linear reconstruction scheme are compared in the inviscid and viscous turbulent flow caculations.

  • PDF

Design of a Low-Vibration Micro-Stepping Controller for Pan-Tilt Camera (팬.틸트 카메라의 저 진동 마이크로스텝핑 제어기 설계)

  • Yoo, Jong-won;Kim, Jung-han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.9
    • /
    • pp.43-51
    • /
    • 2010
  • Speed, accuracy and smoothness are the important properties of pan-tilt camera. In the case of a high ratio zoom lens system, low vibration characteristic is a crucial point in driving pan-tilt mechanism. In this paper, a novel micro-stepping controller with a function of reducing vibration was designed using field programmable gate arrays (FPGA) technology for high zoom ratio pan-tilt camera. The proposed variable reference current (VRC) control scheme reduces vibration decently and optimizing coil current in order to prevent the step motor from occurring missing steps. By employing VRC control scheme, the vibration in low speed could be significantly minimized. The proposed controller can also make very high speed of 378kpps micro-step driving, and increase maximum acceleration in motion profiles.

Effective points for acupuncture are different from induction methods in rat models of arthiritis (관절염 유발 방법에 따른 경혈의 진통효과 차이)

  • Koo, Sung-Tae;Kim, Yu-Sung;Lee, Ji-Eun;Hwang, Hye-Suk;Han, Kyung-Ju;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.3 s.18
    • /
    • pp.49-58
    • /
    • 2006
  • Although the usage of acupuncture for pain has increased in recent years, the mechanisms of acupuncture analgesia (AA) remain unclear. The lack of suitable experimental animal models for persistent pain, which show clear AA, has been the major stumbling block in the investigation of the physiological mechanisms of AA. In the present study, we test AA in two knee arthritis models induced by injection of CFA or carrageenan as persistent pain models. After induction of arthritis, the rat subsequently showed a reduced stepping force of the affected limb for the next several days. Electroacupuncture (EA) was applied to an acupuncture point each on the contralateral forelimb for 30 minutes under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next several hours. EA produced a significant improvement of stepping force of the foot lasting for at least 2 hours when applied to LR2 in CFA model, and applied to ST36 in carrageenan model, but both points did not produce any significant effects in each other model. Further experiments showed that intraperitoneal pretreatment of naltrexone, a non-selective opioid antagonist, did not reduced the EA-induced improvement of stepping force in both of two models. These data suggest that EA produce analgesic effect in knee arthritic pain and the analgesic effect is specific to the acupuncture point depending on painful conditions.

  • PDF

A LATERAL CONTROL ALGORITHM FOE ROLL-TO-ROLL WEB SYSTEM BASED ON BACK-STEPPING APPROACH

  • Choi, Kyung-Huyn;Thanh, Tran Trung;Ko, Jeong-Beom;Kim, Su-Jin;Doh, Yang-Hoi;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1091-1097
    • /
    • 2008
  • Roll-to-roll based manufacturing plays an important role in producing devices at high speed with lower production cost in printed electronics and publishing industry. Web lateral control is one of the most important factors in improving the quality of product and contributes a considerable point in making devices at micrometer-level accuracy. In recent years, most algorithms proposed for web lateral control base on the Shelton‘s model for designing the feedback control system using the PI controller. Experimental results showed that the existing models do not fully describe the characteristics of the lateral dynamics for some typical operating conditions and so result in poor control algorithms. In this paper, a new lateral control algorithm is proposed for web lateral control system based on back-stepping approach. The outcome of this study proves the reliability throughout simulation results in Matlab/Simulink and comparison with the algorithms based on the existing results.

  • PDF

Punching Position Control by Vision System (비전을 이용한 펀칭위치 제어 시스템)

  • 이성철;이영춘;심기중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.981-984
    • /
    • 2004
  • This paper is about the development of Automatic FPC punching instrument. FPC(flexible printed circuit) is used to detect the contact position of K/B and button like a cellular phone. Depending on the quality of the printed ink and position of reference punching point to the FPC, the resistance and current are varied to the malfunctioning values. The size of reference punching point is 2mm and the above. Because the punching operation is done manually, the accuracy of the punching degree is varied with operator's condition. Recently, The punching accuracy has deteriorated severely to the 2mm punching reference hall so that assembly of the K/B has hardly done. To improve this manual punching operation to the FPC, automatic FPC punching system is introduced. Precise mechanical parts like a 5-step stepping motor and ball screw mechanism are designed and tested and low cost PC camera is used for the sake of cost down instead of using high quality vision systems for the FA. Test algorithm shows good results to the designed automatic punching system.

  • PDF