• Title/Summary/Keyword: Step-up and step-down

Search Result 201, Processing Time 0.025 seconds

Electrical properties of Step -Down Multilayer Piezoelectric transformer sintered at $900^{\circ}C$ Low Temperature ($900^{\circ}C$ 저온에서 소결된 깅압용 적층 압전 변압기의 전기적 특성)

  • Lee, Kba-Soo;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.16-16
    • /
    • 2010
  • The multilayer piezoelectric transformer was manufactured using $Pb(Zn_{1/2}W_{1/2})O_3-Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr_{0.48}Ti_{0.52})O_3$ (abbreviated as PZW-PMN-PZT) ceramics and their electrical properties were investigated. The $k_{eff}$ of the input and the output calculated from the resonant and anti-resonant frequencies were 0.403 and 0.233, respectively. The voltage step-up ratio showed the maximum value in the vicinity of 81kHz. The multilayer piezoelectric transformer showed the temperature rise of about $36^{\circ}C$ at the output power of 12w.

  • PDF

Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space (추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험)

  • 한화택;서세영;김명호;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

Development of Wed-Based Courseware in Oral Health Education for Elementary School Children (초등학교 구강보건교육을 위한 코스웨어 개발)

  • 최빈아;장창곡
    • Korean Journal of Health Education and Promotion
    • /
    • v.20 no.2
    • /
    • pp.1-18
    • /
    • 2003
  • The purpose of this study was to develop game style courseware in oral health instruction for elementary school children. The manufacturing equipment and languages which were used to develop the courseware were: Photoshop version 7.0, Illustrator version 10.0, HTML, Dream Weaver MX, Editplus, CSS and Java - script. The data base was built up by using PHP and mySQL over Internet Explorer version 4.0. The contents of courseware for oral health education were based on the list of oral health affaires of the Department of Health and Welfare, 2002. The story of the game ‘Saving Hayani locked down in a castle of a cavity man’ was developed for the learners to learn oral health by inducing learning motivation. A character named ‘Chan i’ was introduced to the learners to be more friendly with the program while they were learning. As the game was made of three step education levels, the learner most pass the prepared test given at each step to advance to a higher level. A database connected to web was constructed to store the scores the learners earned at each step. In conclusion, the courseware will help the elementary school children learn oral health care efficiently through the internet regardless of time and space.

Walkability on Ramps by Gait Analysis (보행자세해석에 의한 경사로의 보행성)

  • 유남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.2
    • /
    • pp.157-166
    • /
    • 1995
  • To investigate walkability of ramps, walking patterns of 18 healthy adults,12 aged 20 to 26 and 6 aged 68 to 76,were studied at free,rhythm constrained walking up or down ramp using goniometer and footswitch Ramp inclinations were set 4,8,12,16,20 degrees. The results were as follows. 1)The step length of subjects were decreased significantly in12$^{\circ}C$′or 16′free downramp walking. With regard to step length, some subject groups walked abnormally in 16" or 20" ramp walking 2) The step width of subjects were increased significantly in 12" or 16" ramp walking. 3) The cadence duration of some subject groups were increased in 12" upramp walking. 4) The double stance duration and double stance ratio of some subject groups were increased significantly in 8",12", or 16"upramp walking. 5) The maximum knee flexion angle of stance phase were increased in 12" ramp walking. 6)Most temporal parameters and spatial parameters of gait were increased or decreassd greatly between 4" ramp and 8" ramp or between 8′ramp and 12′ramp. But statistics significancy were not recognized 7) The results suggest that ramp inclination less than 8′(14%) -12′(21%) is desirable for the normal gait the ramp inclination must not exceed 16" -20" in unavoidable circumstances.

  • PDF

Modified Digital Pulse Width Modulator for Power Converters with a Reduced Modulation Delay

  • Qahouq, Jaber Abu;Arikatla, Varaprasad;Arunachalam, Thanukamalam
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • This paper presents a digital pulse width modulator (DPWM) with a reduced digital modulation delay (a transport delay of the modulator) during the transient response of power converters. During the transient response operation of a power converter, as a result of dynamic variations such as load step-up or step-down, the closed loop controller will continuously adjust the duty cycle in order to regulate the output voltage. The larger the modulation delays, the larger the undesired output voltage deviation from the reference point. The three conventional DPWM techniques exhibit significant leading-edge and/or trailing-edge modulation delays. The DPWM technique proposed in this paper, which results in modulation delay reductions, is discussed, experimentally tested and compared with conventional modulation techniques.

Application for Environment-friendly Retaining Wall Method Composed with Permanent Ground Anchor and Vertical Precast Panel in Cutting Slope Area (영구앵커와 연직 프리캐스트패널을 사용한 절토사면 친환경옹벽공법의 적용사례)

  • Nam, Hong-Ki;Jung, Hong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.87-96
    • /
    • 2010
  • PAP method is a combined measures which consist a anchored retaining wall method with permanent ground anchors and vertical precast concrete panels, step by step on the slope surface. And soil is back filled between slope and vertical precast panels. Therefore, this method is more effective than any other ground anchor reinforcing methods of slope stability, for example cross type concrete block ground anchor or buttress concrete block ground anchor method. Because of increasing effective anchor force and green tree planting.

  • PDF

Dynamic Buckling Characteristics of Arch Structures Considering Geometric Nonlinearity (기하학적 비선형을 고려한 정현형 아치 구조물의 동적 좌굴 특성)

  • 윤태영;김승덕
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.492-497
    • /
    • 2003
  • The dynamic instability for snapping phenomena has been studied by many researches. There is few paper which deal with the dynamic buckling under the load with periodic characteristics, and the behavior under periodic excitation is expected the different behavior against STEP excitation. We investigate the fundamental mechanisms of the dynamic instability when the sinusoidal shaped arch structures subjected to sinusoidal distributed excitation with pin-ends. In this study, the dynamic direct snapping of shallow arches is investigated under not only STEP load excitation but also sinusoidal harmonic excitations, applied in the up-and-down direction. The dynamic nonlinear responses are obtained by the numerical integration of the geometrically nonlinear equations of motion, and examined by the Fourier spectral analysis in order to get the frequency-dependent characteristics of the dynamic instability for various load levels.

  • PDF

A Study on Residential Hybrid Distribution System for Reducing Power Conversion Loss (전력 변환 손실 저감을 위한 하이브리드 주거배전시스템)

  • Byen, Byeng-Joo;Seo, Hyun-Uk;Choi, Jung-Muk;Lee, Young-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.413-421
    • /
    • 2013
  • This paper proposes residential hybrid distribution system that can supply AC power and DC power to AC load and DC load at the same time. This hybrid distribution system consists of three parts: bidirectional inverter, step-up converter and step-down converter. Also that is used to supply voltage to home application is classified of AC load and DC load as load characteristics. The performance of proposed hybrid distribution system is validated through the hardware implementation and the experimental results.

Series Compensated AC Voltage Regulator using AC chopper with Auxiliary Transformer (교류쵸퍼와 보조변압기를 사용한 직렬보상형 교류전압제어장치)

  • 류홍제;김종수;임근희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.463-467
    • /
    • 2003
  • This paper describes an AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. A detail study of step down AC voltage regulator is described and two kinds of novel step-up/down voltage regulator for AVR application are proposed. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as AC voltage regulator for special purpose very efficiently.

Adapted Sequential Pattern Mining Algorithms for Business Service Identification (비즈니스 서비스 식별을 위한 변형 순차패턴 마이닝 알고리즘)

  • Lee, Jung-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.4
    • /
    • pp.87-99
    • /
    • 2009
  • The top-down method for SOA delivery is recommended as a best way to take advantage of SOA. The core step of SOA delivery is the step of service modeling including service analysis and design based on ontology. Most enterprises know that the top-down approach is the best but they are hesitant to employ it because it requires them to invest a great deal of time and money without it showing any immediate results, particularly because they use well-defined component based systems. In this paper, we propose a service identification method to use a well-defined components maximally as a bottom-up approach. We assume that user's inputs generates events on a GUI and the approximate business process can be obtained from concatenating the event paths. We first find the core GUIs which have many outgoing event calls and form event paths by concatenating the event calls between the GUIs. Next, we adapt sequential pattern mining algorithms to find the maximal frequent event paths. As an experiment, we obtained business services with various granularity by applying a cohesion metric to extracted frequent event paths.