• Title/Summary/Keyword: Step width

Search Result 444, Processing Time 0.028 seconds

Characteristics of step-pool structure in the mountain streams around Mt. Jiri (지리산 주변 산지하천의 step-pool 구조 특성)

  • Kim, Ki Heunga;Jung, Hea Reyn
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.313-322
    • /
    • 2018
  • The height of the steps was almost the same as the grain size of bed materials and increased with channel slope. The step widths and step wavelengths are almost the same size, and the step wavelength was decreased when the channel slope was increased. It was analyzed that there was a clear correlation between channel width and step width, and the step width increases with channel width. In addition, the step wavelength was scaled by channel width, and the step height is governed by the grain size of the rock forming the step, so that the profile structure of the step-pool was changed according to the channel slope. the scale of the pool was found to be highly correlated with the channel width, grain size, and slope gradient. Therefore, the characteristics of step-pool structure in mountain streams were influenced by various factors, but it can be explained as the grain size, channel width and channel slope.

Step-Size Control for Width Adaptation in Radial Basis Function Networks for Nonlinear Channel Equalization

  • Kim, Nam-Yong
    • Journal of Communications and Networks
    • /
    • v.12 no.6
    • /
    • pp.600-604
    • /
    • 2010
  • A method of width adaptation in the radial basis function network (RBFN) using stochastic gradient (SG) algorithm is introduced. Using Taylor's expansion of error signal and differentiating the error with respect to the step-size, the optimal time-varying step-size of the width in RBFN is derived. The proposed approach to adjusting widths in RBFN achieves superior learning speed and the steady-state mean square error (MSE) performance in nonlinear channel environment. The proposed method has shown enhanced steady-state MSE performance by more than 3 dB in both nonlinear channel environments. The results confirm that controlling over step-size of the width in RBFN by the proposed algorithm can be an effective approach to enhancement of convergence speed and the steady-state value of MSE.

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

Hybrid Pulse Width Modulation Strategy for Wide Speed Range in IPMSM with Low Cost Drives

  • Ahn, Han-woong;Go, Sung-chul;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.670-674
    • /
    • 2016
  • The control performance of hybrid PWM inverter using a phase current measurement is presented in this paper. The hybrid PWM technique consists of space vector pulse width modulation (SVPWM) and six-step voltage control operation. The SVPWM is performed to reduce the harmonic components in the low speed region, and the six-step modulation is applied to increase the maximum speed of the IPMSM in the high speed region. Therefore, it is possible to obtain a great performance in both the low speed range and high speed range. However, the six-step modulation cannot be completely implemented, since the inverter that includes the lag-shunt sensing method has an immeasurable current region. In this paper, a quasi-six-step modulation using a modified voltage vector is proposed. The validity and usefulness of the proposed PWM technique is verified by MATLAB/Simulink and experimental results.

The Effect of Height Increase Elevator Shoes Insole on Gait and Foot Pressure (키높이 깔창이 성인남성의 보행 및 발의 압력분포에 미치는 영향)

  • Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.2
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of 0cm, 2.5cm, 5cm height increase elevator shoes insole on gait and foot pressure Methods: Fifteen young adult were recruited this study. Gait and foot was measured by Gait AnalyzerTM(Tech Storm Inc. korea). Statistical analysis was used one-way ANOVA to know difference between 0cm, 2.5cm insole and 5cm insole Results: There was no significantly difference on foot length, foot width, foot angle, step time during gait. But step length and step width was significantly difference during gait. There was no significantly difference on gait ratio during stance phase. There was significantly difference on forefoot pressure and rearfoot pressure ratio. Conclusion: These results indicate that height increase elevator shoes insole may be caused step length, step width decreaseed during gait. It caused forefoot pressure increased and rearfoot pressure decreased on foot.

A Study on the Fitness of Children's Shoes -Centered on the Correlation of Shoes Size and Walking- (아동화의 적합성에 관한 연구 -신발크기와 보행과의 관계를 중심으로-)

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.3
    • /
    • pp.23-34
    • /
    • 1991
  • With 10 subjects of 6-year-old children residing in Pusan, I analyzed the relation of walking types(step angle, step width, step and stride) and wear comfort according to the style and size fo shoes in order to reveal the fitness of children's shoes centered on the relationship of shoes size and walking. Three styles of children's shoes(laced and unlaced formal shoes, magic-taped sports shoes) ranging in five different size were used. The following are conclusions. 1. As to step angle, there was no conceivable change in the left side, while the right side had a significance in accordance with the shoes size at p<0.001. As the size grew, right step angle of all shoes increased, with unlaced shoes having more influence than others. Step angle were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 2. As to step width, there was no conceivable change in the style of shoes, while shoes size had a significance at p<0.001. As the size grew, step width also increased. Step width were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 3. Step and stride, however, took no significance at all, since they were not influenced by the size or style of the shoes. 4. Wear comfort had a significance at the level of p<0.001. Since it was influenced by the size or style of the shoes. The best wear comfort was felt when all the sampled shoes had laces and magic tapes as well as the size with the difference of 5-10mm between foot size and shoes size.

  • PDF

Effect of Step Width and TOA on Q-Angle and CTA in Walking (보행에 있어서 보격과 발목각도가 종경골각 및 대퇴사두근각에 미치는 영향)

  • Hwangbo Gak;Lee Jin-Hee;Chung Hyung-Kuk;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.33-47
    • /
    • 1996
  • This study was performed to examine the correlation between calcaneus to tibia angle and Q-angle, and the effects of step width and toe out angle on the calcaneus to tibia angle and Q-angle. The age of participated subjects was from 19 to 29 years(Mean=22.95, SD=2.23) who have no significant orthopedic and neurological dysfunction. The marking tapes for measurement of Q-angle and calcaneus to tibia angle were placed on seven location of each subject. Video data were collected while the subject walked on a walking grid. The result as follows : 1. There were significant differences in the step width, toe out angle, and Q-angle but not calcaneus to tibia angle between male and female. 2. There were significant differences in toe calcaneus to tibia angle and Q-angle n step width increased, respectively. 3. There were significant differences between tee out angle and calcaneus to tibia angle but not toe out angle and q-angle. 4. There was statistically significant correlation between calcaneus to tibia angle and Q-angle.

  • PDF

Optimal Design of Orifice typed Distribution Channel using Step Method Program (Step method 프로그램을 이용한 orifice 분배수로의 최적 설계에 관한 연구)

  • Park, No-Suk;Park, Sangcheol;Kim, Sung-soo;Lee, Seonjoo;Jeong, Nam-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.691-700
    • /
    • 2006
  • This study conducted to optimize the design and operation of orifice typed distribution channels which were generally constructed to link the rapid mixing process and flocculation/sedimentation basin. To accomplish the goal of this study, programming step method using FORTRAN 90, was applied it to simulate the performance of existing distribution channel in the selected S DWTP (Drinking Water Treatment Plant). The proposed step method program was validated in terms of the feasibility with comparison between the measurement and prediction value in each orifice. From the evaluation results of the current conditions with the design and operation, it was revealed that the existing gradient of the tapered channel is not appropriate. Also, we suggested that in the case of the inlet width being 3.5m, reducing the downstream width by about 0.5m would make more equitable distribution flow in the channel. Consequently, dealing with various conditions of the design and operation with distribution channel, we could conclude that for the parallel typed channel, as the width is wider and the diameter of orifice is smaller, the more equitable distribution occur. In addition, the inlet flowrate and the number of orifice can affect the flow velocity in the channel.

Effects of the Education about the Self-application of the Kinesio-Taping for the Adult Women with Chronic Low Back Pain on Pain, Satisfaction and Gait (키네시오 테이핑 자가적용 교육이 만성요통 성인 여성들의 통증, 만족도 및 보행에 미치는 영향)

  • Son, Sungmin;Kwag, Sungwon;Jeon, Byoungjin
    • 재활복지
    • /
    • v.22 no.4
    • /
    • pp.1-22
    • /
    • 2018
  • We aimed to analyze the effects of Kinesio-Taping on pain, satisfaction, and gait, and to provide basic data on the self-application of this method. The participants were 30 adult women with chronic low back pain. Kinesio-Taping was applied for 2 weeks, followed by 4 weeks of self-application education and self-application. The participants' pain levels were analyzed using the visual analog scale, satisfaction was analyzed using the Canadian Occupational Performance Measure, and gait was analyzed in terms of stride length, step length, step width, and gait time using the Walkway MG-1000 gait analyzer. The results of the pain showed the statistically significant decrease steadily (p<0.001) and the results of the satisfaction showed the statistically significant increase steadily (p<0.001) from the application of the Kinesio-Taping. Also, according to the In-Object verification between pre-test, taping application (after 2 weeks) and Self-application (after 4 weeks), the results of the satisfaction showed statistically significant difference (p<0.001). According to the gait analysis, the results of the stride length and step length showed the statistically significant increase steadily (p<0.001) and the results of the step width and gait time showed the statistically significant decrease steadily (p<0.001) from the application of the Kinesio-Taping. Also, according to the In-Object verification between pre-test, taping application (after 2 weeks) and Self-application (after 4 weeks), the results of the step width showed statistically significant difference (p<0.001). Thus, the self-application education about the Kinesio-Taping should be considered to reduce the pain and improve the performance level of the activities of daily life through the improvement of the self-management ability and to induce the active participation in the self-management activities and increase the satisfaction.

Modeling and Optimization of RMS Pulse Width for Transmission in Dispersive Nonlinear Fibers

  • Lee, Jong-Hyung
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.258-263
    • /
    • 2003
  • Simple algebraic expressions are derived to approximate the optimal input RMS pulse width and the resulting output RMS pulse width in single-mode fibers. The results are compared with the previously published methods and with numerical results by the split-step Fourier method. In addition, for a transform-limited Gaussian input pulse, it is shown that there is no optimum input pulse width to minimize the output spectrum width. Finally, with fiber nonlinearity, it is shown mathematically that there is not an optimum input pulse width to minimize the product,${\sigma}_t{\sigma}_{\omega}$, which is inversely proportional to the transmission capacity of WDM systems.