• 제목/요약/키워드: Step time

검색결과 5,413건 처리시간 0.034초

등산폴 사용이 보행과 근활동에 미치는 영향 (The Effects of Hiking Poles-using on Gait and Muscle Activity)

  • 서정석;김용운;윤태진
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.209-215
    • /
    • 2007
  • The purpose of this study was to investigate gait factor and muscle activity depending on hiking poles-using. Eight healthy men volunteered for this experiment. Each of them performed down-hill walking with hiking poles-using and without poles at speed of 3.5km/h for 45 minutes on a treadmill. The treadmill was set 25% down-hill inclination. Kinematic data collected in 60Hz were recorded and analyzed by using 2D motion capture system to measure step time and step length so on. And the lower extremity muscle activities were simultaneously recorded in 1500Hz and assessed by using EMG. The statistical analysis was the paired t-test with repeated measures to compare between hiking poles-using and without poles. The level of statistical significance for all tests was .05. The results of this study were following : Step time was showed statistically different according to pole conditions. That is, the case of poles-using was longer than without poles in step time. Also, step length was showed statistically different between two conditions. Step length about trials with poles was longer than trials without poles. In the muscle activity, the case of all muscles was not showed statistical significance about pole conditions. However, in most muscles IEMG, there were some decreasing-trend relatively when hiking polesusing.

다출력 유도가열 공정을 이용한 다공질 6061 알루미늄 합금의 기공 제어 공정 (A Process for the Control of Cell Size of 6061 Al foams by Multi-step Induction Heating Method)

  • 윤성원;강충길
    • 소성∙가공
    • /
    • 제12권5호
    • /
    • pp.449-456
    • /
    • 2003
  • Multi-step induction heating process was applied to the powder compact melting technique as a new heating process to achieve pinpoint accuracy, faster cycle time, repeatability, non-contact and energy-efficient heat in a minimal amount of time. The objective of this study is the establishment of the input data diagram of multi step induction heating process for automation of the fabrication process of 6061 Al foams with desired density. At first, proper induction coil was designed to obtain a uniform temperature distribution over the entire cross sectional area of specimen. By using this coil, foaming experiments were performed to investigate the multi-step induction heating conditions such as capacity, temperature and time conditions of each heating and holding step. On the basis of the obtained multi-step induction heating conditions, relationship between final heating temperature and fraction of porosity was investigated.

High fidelity transient solver in STREAM based on multigroup coarse-mesh finite difference method

  • Anisur Rahman;Hyun Chul Lee;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3301-3312
    • /
    • 2023
  • This study incorporates a high-fidelity transient analysis solver based on multigroup CMFD in the MOC code STREAM. Transport modeling with heterogeneous geometries of the reactor core increases computational cost in terms of memory and time, whereas the multigroup CMFD reduces the computational cost. The reactor condition does not change at every time step, which is a vital point for the utilization of CMFD. CMFD correction factors are updated from the transport solution whenever the reactor core condition changes, and the simulation continues until the end. The transport solution is adjusted once CMFD achieves the solution. The flux-weighted method is used for rod decusping to update the partially inserted control rod cell material, which maintains the solution's stability. A smaller time-step size is needed to obtain an accurate solution, which increases the computational cost. The adaptive step-size control algorithm is robust for controlling the time step size. This algorithm is based on local errors and has the potential capability to accept or reject the solution. Several numerical problems are selected to analyze the performance and numerical accuracy of parallel computing, rod decusping, and adaptive time step control. Lastly, a typical pressurized LWR was chosen to study the rod-ejection accident.

Dependence structure analysis of KOSPI and NYSE based on time-varying copula models

  • Lee, Sangyeol;Kim, Byungsoo
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권6호
    • /
    • pp.1477-1488
    • /
    • 2013
  • In this study, we analyze the dependence structure of KOSPI and NYSE indices based on a two-step estimation procedure. In the rst step, we adopt ARMA-GARCH models with Gaussian mixture innovations for marginal processes. In the second step, time-varying copula parameters are estimated. By using these, we measure the dependence between the two returns with Kendall's tau and Spearman's rho. The two dependence measures for various copulas are illustrated.

와전류를 포함하는 시간차분 해석의 계산오차에 대한 연구 (Study on the Error Estimation of Time-step Analysis for a Problem with Eddy Current)

  • 최명현;김병택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.854-855
    • /
    • 2008
  • This paper deals with the computation error produced in the time step analysis for a electric machine with eddy current. To investigate the error in quantity, the analytic equations representing the steady state results of time-step analysis are deduced. Using the equations, the characteristics of errors are calculated for a general electric circuit, with variation of the circuit parameters and step size.

  • PDF

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Kang, SungHee;Cho, Jin Dong;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.39-44
    • /
    • 2017
  • This study aims to analyze dose distribution and treatment time of endobronchial brachytherapy (EBBT) by changing the position step size of the dwell position. A solid water phantom and an intraluminal catheter were used in the treatment plan. The treatment plans were generated for 3, 5, 7, and 10 cm treatment lengths, respectively. For each treatment length, the source position step sizes were set as 2.5, 5, and 10 mm. Three reference points were set 1 cm away from the central axis of the catheter, along the axis, for uniform dose distribution. Volumetric dose distribution was calculated to evaluate the dosimetric effect. The total radiation delivery time and total dwell time were estimated for treatment efficiency, which were increased with position step sizes. At half-life time, the differences between the position step sizes in the total radiation delivery time were 18.1, 15.4, 18.0, and 24.0 s for 3, 5, 7, and 10 cm treatment lengths, respectively. The dose distributions were more homogenous by increasing the position step sizes. The dose difference of the reference point was less than 10%. In brachytherapy, this difference can be negligible. For EBBT, the treatment time is the key factor while considering the patient status. To reduce the total treatment time, EBBT can be performed with 2.5 mm position step size.

아급성 기저핵 뇌졸중 후 편마비 환자의 보행양상의 변화 : 후향적 연구 (Changes in the Gait Pattern of Hemiparetic Patients with Subacute Basal Ganglia Stroke: a Retrospective Study)

  • 홍해진;김철현;성강경;이상관
    • 대한한방내과학회지
    • /
    • 제37권6호
    • /
    • pp.990-997
    • /
    • 2016
  • Objectives: This study observed changes in gait pattern according to the motor grade of the paretic lower limb in patients with basal ganglia stroke who are in the subacute phase. Methods: We used the Manual Muscle Test (MMT) to evaluate the motor grade of the paretic lower limb of 21 patients with subacute basal ganglia stroke and then divided them into two groups based on the MMT results. Stroke patients with a motor grade above Gr. III were put in group I (15 people) and those with a grade less than Gr. III in group II (6 people). We also estimated spatiotemporal factors using treadmill gait analysis equipment. The values were gait velocity, step length, step time, double support phase, and cadence. The first measure was conducted during the early period of admission and the second was between four and five weeks after admission. Results: In Group I, the gait velocity and step length of both legs significantly increased. In Group II, the step length and step time of the paretic side and the gait velocity tended to decrease, but not significantly. The step length of the paretic side in Group II was significantly longer than that in Group I at the first measure. The step time of the paretic side in Group I was significantly shorter than that in Group II and gait velocity and cadence in Group I were significantly higher than in Group II at the second measure. Conclusions: The gait parameters of all stroke patients improved in terms of time. In addition, the changes in gait pattern were different depending on the motor grade of the paretic lower limb.

이차원과도열전도에 대한 음함수형 유한차분법의 정도에 미치는 공간증분 및 시간간격의 영향 (Effects of Space Increment and Time Step to the Accuracy of the Implicit Finite Difference Method in a Two-Dimensional Transient Heat Conduction Problem)

  • 조권옥;이용성;오후규
    • 한국수산과학회지
    • /
    • 제18권1호
    • /
    • pp.15-22
    • /
    • 1985
  • The study on computation time, accuracy, and convergency characteristic of the implicit finite difference method is presented with the variation of the space increment and time step in a two-dimensional transient heat conduction problem with a dirichlet boundary condition. Numerical analysis were conducted by the model having the conditions of the solution domain from 0 to 3m, thermal diffusivity of 1.26 $m^2/h$, initial condition of 272 K, and boundary condition of 255.4 K. The results obtained are summarized as follows : 1) The degree of influence with respect to the accuracy of the time step and space increment in the alternating-direction implicit method and Crank-Nicholson implicit method were relatively small, but in case of the fully implicit method showed opposite tendency. 2) To prescribe near the zero for the space increment and tine step in a two dimensional transient problem were good in a accuracy aspect but unreasonable in a computational time aspect. 3) The reasonable condition of the space increment and the time step considering accuracy and computation time could be generalized with the Fourier modulus increment, F, ana dimensionless space increment, X, irrespective of the solution domain.

  • PDF

지진파 전파 모의를 위한 불균등 격자 및 시간간격 유한차분법 (Discontinuous Grids and Time-Step Finite-Difference Method for Simulation of Seismic Wave Propagation)

  • 강태섭;박창업
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.50-58
    • /
    • 2003
  • We have developed a locally variable time-step scheme matching with discontinuous grids in the flute-difference method for the efficient simulation of seismic wave propagation. The first-order velocity-stress formulations are used to obtain the spatial derivatives using finite-difference operators on a staggered grid. A three-times coarser grid in the high-velocity region compared with the grid in the low-velocity region is used to avoid spatial oversampling. Temporal steps corresponding to the spatial sampling ratio between both regions are determined based on proper stability criteria. The wavefield in the margin of the region with smaller time-step are linearly interpolated in time using the values calculated in the region with larger one. The accuracy of the proposed scheme is tested through comparisons with analytic solutions and conventional finite-difference scheme with constant grid spacing and time step. The use of the locally variable time-step scheme with discontinuous grids results in remarkable saving of the computation time and memory requirement with dependency of the efficiency on the simulation model. This implies that ground motion for a realistic velocity structures including near-surface sediments can be modeled to high frequency (several Hz) without requiring severe computer memory

  • PDF