• Title/Summary/Keyword: Step height

Search Result 473, Processing Time 0.036 seconds

Automatic Process Design System for Cold Forging of Fasteners with Various Head Geometries (다양한 머리 형상을 갖는 체결구의 냉간 단조 자동 공정 설계 시스템)

  • 김홍석;임용택
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1994.10a
    • /
    • pp.141-148
    • /
    • 1994
  • In order to improve the productivity of cold forging at low production cost, an integrated system's approach is necessary in handling the material preparation and the optimum process design, considering the forming machines, tooling, and operation including quality control. As the first step toward this approach, an expert system for multi-stage cold forging process design for fasteners with various head geometries is developed using Prolog language on IBM 486 PC. For effective representation of the complex part geometries, the system uses the multiple element input, and the forward inference scheme in determination of the initial billet size and intermediate forging steps. In order to determine intermediate steps, the basic empirical rules for extrusion, heading, and trimming were applied. The required forming loads and global strain distributions at each forging step were calculated and displayed on the PC monitor. The designed process sequence drawing can be obtained by AutoCAD. The developed system will be useful in reducing trial and error of design engineers in determining the diameter and height of the initial cylindrical billet from the final product geometry and the intermediate necessary sequences.

  • PDF

Preparation and Its Properties of YBCO Superconductor Induced by Seeds

  • Shan, Y.Q.;Soh, D.W.;Fan, Z.G.;Men, M.F.;Wang, W.H.;Zhao, Z.X.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.371-373
    • /
    • 1998
  • The SmBa$_2$Cu$_3$O$\sub$x/ single crystals were used as seeds to induced YBCO growth in MTG process. As the result, the large bulk oriented YBCO superconductors were prepared with dimension of plane 21mm and 32mm in diameter and 10mm in height. The typical Jc value of the sample is 6.5${\times}$10$^4$A/$\textrm{cm}^2$ and its flux float force is 4.6N/$\textrm{cm}^2$. The oxygen absorption in large bulk textured YBCO samples in pure oxygen was studied at several constant temperatures. It can be divided into two steps: a chemical reaction step and a diffusion step.

  • PDF

Preparation and Its Properties of YBCO Superconductor Induced by Seeds

  • Shan, Y.Q.;Soh, D.W.;Fan, Z.G.;Men, M.F.;Wang, W.H.;Zhao, Z.X.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.491-493
    • /
    • 1998
  • The SmBa$_2$Cu$_3$O$\sub$x/ single crystals were used as seeds to induced YBCO growth in MTG process. As the result, the large bulk oriented YBCO superconductors were prepared with dimension of plane 21mm and 32mm in diameter and 10mm in height. The typical Jc value of the sample is 6.5${\times}$10$^4$A/$\textrm{cm}^2$ and its flux float force is 4.6N/$\textrm{cm}^2$. The oxygen absorption in large bulk textured YBCO samples in pure oxygen was studied at several constant temperatures. It can be divided into two steps: a chemical reaction step and a diffusion step.

  • PDF

A Study on the Installation Planing of Sanitary Ware (남성용 소변기 설치계획에 관한 연구)

  • 이용의
    • Korean Institute of Interior Design Journal
    • /
    • no.18
    • /
    • pp.3-8
    • /
    • 1999
  • In accordance with the growing up to a fine-built national physique on national economic rapid growth, It should be made a partial amendment on the Installation planing of sanitary ware. If users who regard have no problem as using facilities in a unisex toilet, It'll be not only falling down the separation of toilet booth with substantial sanitary problems step by step as follow. 1. The urinal should be pay due regard to such a shape which intercepts stream before the point of dispersion and variations in splash effects according to angles between stream and contact urinal surface with deferent of age and health of users 2. Urinal should be fit for the perineum height of male and so It could be install differently according to the Anatomical Percentile of users.

  • PDF

Visualization Of Aerial Color Imagery Through Shadow Effect Correction

  • Sohn, Hong-Gyoo;Yun, Kong-Hyun;Yang, In-Tae;Lee, Kangwon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.02a
    • /
    • pp.64-72
    • /
    • 2004
  • Correction of shadow effects is critical step for image interpretation and feature extraction from aerial imagery. In this paper, an efficient algorithm to correct shadow effects from aerial color imagery is presented. The following steps have been performed to remove the shadow effect. First, the shadow regions are precisely located using the solar position and the height of ground objects derived from LIDAR (Light Detection and Ranging) data. Subsequently, segmentation of context regions is implemented for accurate correction with existing digital map. Next step, to calculate correction factor the comparison between the context region and the same non-shadowed context region is made. Finally, corrected image is generated by correcting the shadow effect. The result presented here helps to accurately extract and interpret geo-spatial information from aerial color imagery

  • PDF

The Effects of Obstacle Height on the Stepping Over Gait in Parkinson's Patients (장애물 높이가 파킨슨 환자들의 장애물 보행에 미치는 영향)

  • Kim, Mi-Young;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.11-17
    • /
    • 2008
  • Falls associated with tripping over an obstacle can be dangerous, yet little is known about the strategies used for stepping over obstacles by Parkinson's patients. The purpose of this study was to investigate stepping over gait characteristics according to obstacle height in Parkinson's patients. The gait of 7 Parkinson's patients was examined during a 5.0 m approach to, and while stepping over, obstacles of 0, 2.5, 5.2, and 15.2 cm. Only five Parkinson's patients were able to clear all obstacles successfully; as such, only their data were analyzed. A one-way ANOVA for repeated measures was employed for selected kinematic variables to analyze the differences of the height of four obstacles. The results showed significant differences between obstacle height and: approaching speed (AS), foot clearance from the obstacle(FC), and step width (SW). The results showed no significant differences between obstacle height and: crossing speed (CS), toe distance (TD), and heel distance (HD). This strategy tends to reduce the risk of toe contact with the obstacle. Parkinson's patients were stepping over the obstacle slowly, stably and inefficiently.

Two-Wavelength Phase-Shifting Projection $Moir\acute{e}$ Topography for Measurement of Three-Dimensional Profiles with High Step Discontinuities (고단차 불연속 형상의 3차원 측정을 위한 이중파장 위상천이 영사식 무아레)

  • Kim, Seung-Woo;Oh, Jung-Taek;Jung, Moon-Sik;Choi, Yi-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1129-1138
    • /
    • 1999
  • [$Moir\acute{e}$] technique is now being extensively investigated as a fast non-contact means of three-dimensional profile measurement especially for reverse engineering. One problem with $moir\acute{e}$ technique is so called $2\pi$-ambiguity problem that limits the maximum step height difference between two neighboring sampling points to be less than half the equivalent wavelength of $moir\acute{e}$ fringes. In this investigation, a new two-wavelength scheme of projection $moir\acute{e}$ topography is proposed and tested to cope with the $2\pi$-ambiguity problem. Experimental results are discussed to assess the new method in measuring large objects with high step discontinuities.

High-Density Quantum Nanostructure for Single Mode Distributed Feedback Semiconductor Lasers by One-Step Growth (단일 공정에 의한 고효율 단일모드 반도체 레이저 구조 제작을 위한 고밀도 양자 나노구조 형성)

  • Son, Chang-Sik;Baek, Jong-Hyeob;Kim, Seong-Il;Park, Young-Ju;Kim, Yong-Tae;Choi, Hoon-Sang;Choi, In-Hoon
    • Korean Journal of Materials Research
    • /
    • v.13 no.8
    • /
    • pp.485-490
    • /
    • 2003
  • We have developed a new way of the constant growth technique to maintain a grating height of originally-etched V-groove of submicron gratings up to 1.5 $\mu\textrm{m}$ thickness by a low pressure metalorganic chemical vapor deposition. The constant growth technique is well performed on two kinds of submicron gratings that made by holography and electron (e)-beam lithography GaAs buffer layer grown on thermally deformed submicron gratings has an important role in recovering the deformed grating profile from sinusoidal to V-shaped by reducing mass transport effects. The thermal deformation effect on submicron gratings made by e-beam lithography is less than that on submicron gratings made by holography. The constant growth technique is an important step to realize complex optoelectronic devices such as one-step grown distributed feedback lasers and two-dimensional photonic crystals.

ZnO thin films used in the piezoelectric layer of FBAR devices were deposited by 2-step methods using ALD equipment (FBAR 소자의 압전층으로 사용되는 ZnO 박막의 증착시 ALD틀 이용한 2-step 법 적용에 관한 연구)

  • Lee, Soon-Bum;Park, Sung-Hyun;Lee, Neung-Heon;Shin, Young-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1651-1652
    • /
    • 2006
  • In this study, the 2-step methode by ALD equipment was used to improve the characteristics of ZnO thin films used in a piezoelectric layer when the FBAR devices of a SMR type are fabricated. The Height of formed buffer layer was $400{\AA}$ and ZnO thin film of $13600{\AA}$ was deposited by RF sputter on the buffer layer. When ZnO thin films are deposited, deposition conditions such as pressure, injection time of source and purge time were changed variously. The characteristics of piezoelectric layer such as a crystal orientation and micro-structure of deposited ZnO thin films were studied by SEM, AFM and XRD.

  • PDF

The Effect of applying Subsidiary step developed for CPR on the main stretcher during movement (이동 중 주들것에서 심폐소생술을 위해 개발된 보조발판(C-step)의 적용 효과)

  • Shim, Gyu-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5950-5957
    • /
    • 2012
  • CPR with minimized hands-off time is one of integral factors for the improvement of the survival rate of patients. The purpose of this study was to examine the relationship of the installation of C-steps on the main stretcher to CPR accuracy and errors. The subjects in this study were 70 paramedics in 10 firehouses in the province of C(35 for control group, 35 for experimental group), and their CPR accuracy on the main stretchers was checked. As a result, it's found that the main stretchers equipped with the C-steps served to boost the accuracy of chest compression by creating suitable environments for that in terms of height and posture(t=65.104, p=.000), to improve the accuracy of artificial respiration by providing a proper amount of ventilation(t=5.207, p=.000), and to bolster the self-confidence of the paramedics about CPR(t=-10.612, p=.000). In conclusion, the mounting of C-steps on the main stretcher is expected to be of use for the improvement of the survival rate of cardiac-arrest patients by ensuring the precise performance of high-quality CPR.