• 제목/요약/키워드: Step cooling

검색결과 196건 처리시간 0.023초

하나로의 안전성 관련 가동 중 검사 (In-Service Inspection for Safety Rotated Piping in HANARO)

  • 박용철
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.14-18
    • /
    • 2001
  • The primary cooling piping of HANARO is classified as safety class 3, seismic class 1 and quality class Q. This piping as safety related feature has been designed, manufactured and tested in accordance with ASME SEC. Ⅲ, DIV 1, Class 3. In October of 2000, the first step of the in-service inspection for this piping was carried out in accordance with ASME SEC. XI. This describes the results of the Inspection including the preparation of inservice inspection plan and inspection method. It is verified through the results that the safety related piping is maintained the mechanical and structural Integrities.

  • PDF

연속주조 몰드의 구조해석 (Structural Analysis of Continuous Casting Mold)

  • 원종진;이종선;홍석주
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.104-110
    • /
    • 2001
  • The objective of this study is structural analysis of continuous casting mold. A two-dimensional finite element model was developed to compute the temperature distribution, thermal stress and thermal strain behavior for continuous casting mold. Structural analysis was made using thermal analysis result, utilizing transient analysis of ANSYS. This structural analysis results, many variables such as casting speed, cooling condition film coefficient, convection and load condition are considered.

  • PDF

Dimethyl Ether(DME) 합성을 위한 파일럿 규모의 고정층 반응기의 모델링과 모사를 통한 향류 냉각방식과 포화액체 풀비등 방식의 비교 (Comparison of Counter-Current Cooling and Pool Boiling System Through Modeling and Simulation of a Pilot-Scale Fixed bed Reactor for Dimethyl Ether(DME) Synthesis)

  • 송대성;고재욱;윤인섭
    • Korean Chemical Engineering Research
    • /
    • 제47권4호
    • /
    • pp.446-452
    • /
    • 2009
  • 최근 청정대체에너지로 각광을 받고 있는 dimethyl ether(DME)를 천연가스를 이용하여 직접 생산하는 1단계법의 고정층 촉매 반응기를 모사하였다. 1단계법의 고정층 반응기의 경우, 발열 반응인 메탄올 합성반응과 메탄올 탈수 반응이 동시에 일어나기 때문에 촉매의 비활성화를 일으킬 수 있는 hot spot의 발생을 막는 것이 가장 중요하다. 따라서 향후 상용공정에 적용 가능한 향류 냉각방식(count-current cooling system)과 포화액체 풀비등 방식(pool boiling system)을 적용하여 반응기 거동을 모사하고 이를 비교하였다. CO 전환율과 DME 생산성 면에서 향류 냉각방식이 더 효과적이었다. 하지만 포화비등액체 풀비등 방식이 더 작은 온도 범위에서 운전되어 hot spot(국소 고온점)의 가능성을 낮추고 더 안정적인 반응기 운전범위를 확보할 수 있었다.

모빌리티 전용 저장장치의 고온 고장 방지를 위한 온도 관리 시스템 설계 (A Design of Temperature Management System for Preventing High Temperature Failures on Mobility Dedicated Storage)

  • 이현섭
    • 사물인터넷융복합논문지
    • /
    • 제10권2호
    • /
    • pp.125-130
    • /
    • 2024
  • 모빌리티 기술의 급격한 성장으로 산업 분야의 수요는 차량 내에 다양한 장비와 센서의 데이터를 안정적으로 처리할 수 있는 저장장치를 요구하고 있다. NAND 플래시 메모리는 외부에 강한 충격뿐만 아니라 저전력, 빠른 데이터 처리 속도의 장점이 있기 때문에 모빌리티 환경의 저장장치로 활용되고 있다. 그러나 플래시 메모리는 고온에 장기 노출될 경우 데이터 손상이 발생할 수 있는 특징이 있다. 따라서 태양 복사열 등 날씨나 외부 열원에 의한 고온 노출이 빈번한 모빌리티 환경에서는 온도를 관리하기 위한 전용 시스템이 필요하다. 본 논문은 모빌리티 환경에서 저장장치 온도 관리하기 위한 전용 온도 관리 시스템을 설계한다. 설계한 온도 관리 시스템은 전통적인 공기 냉각 방식과 수 냉각방식의 기술을 하이브리드로 적용하였다. 냉각 방식은 저장장치의 온도에 따라 적응형으로 동작하도록 설계하였으며, 온도 단계가 낮을 경우 동작하지 않도록 설계하여 에너지 효율을 높였다. 마지막으로 실험을 통해 각 냉각방식과 방열재질의 차이 따른 온도 차이를 분석하였고, 온도 관리 정책이 성능을 유지하는데 효과가 있음을 증명하였다.

투명대 존재/부재 햄스터 난자의 동결보존;1-단계 평형과 2-단계 융해의 효과 (Cryopreservation of Zona-intact/-free Hamster Oocytes;Effect of 1-Step Equilibration and 2-Step Thawing)

  • 정구민;방명걸;김석현;신창재;김정구;문신용;이진용;장윤석
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제19권2호
    • /
    • pp.143-152
    • /
    • 1992
  • The present experiments were focussed to modify a short slow-cooling protocol used for freezing of early stage embryo(Testart et al., 1986) and also to apply the modified method for the cryopreservation of hamster oocytes with Zona or without. The protocol was modified by changing the 4-step equilibration into 1-step and the 1-step thawing into 2-step. The oocytes were added in 1.5M PROH and 0.1M Sucrose, seeded at $-7^{\circ}C$, slow cooled($0.3^{\circ}C$/min) to $-30^{\circ}C$ before plunging to $-196^{\circ}C$. The oocytes were thawed at $23-25^{\circ}C$ air(20sec/150sec) and/or 33-35 water(10sec). The survival of the frozen-thawed oocytes was determined by morphologic criteria and their fertilizing ability was also estimated by Sperm Penetration Assay(SPA) system(Chang et al, 1990) using fertile men semen sample. One-step equilibration showed slightly higher survival rate(83.9% vs. 71.0%) and fertilization rate(83.9% vs. 71.0%) compared with four-step(p>0.05). And two-step thawing(air & water exposing) of oocytes frozen after 1-step equilibration showed significantly higher survival rate(96.3%) than one-step thawing at air(85.2%) or water(65.0%) only(p<0.05). Therefore, by the modified method(l-step equilibration & 2-step thawing), Zona-intact(ZI) and Zona-free(ZF) oocytes were frozen and thawed. ZI-oocytes showed significantly higher survival rate(95.4%, 308/323 vs. 67.6%, 240/355) than ZF-oocytes(P<0.01). But the survival of ZF-oocytes was as high as ZI-oocytes in fourteen of twenty-four replicates. ZI-oocytes was also significantly higher fertilization rate($92.4{\pm}8.9%$ vs. $63.7{\pm}18.5%$) and higher mean number of penetrated sperm($6.2{\pm}4.2$ vs. $3.9{\\pm}3.3$) than ZF-oocytes, but not higher than control(fresh oocytes;$99.3{\pm}2.4%$, $8.4{\pm}4.2$)(P<0.001). Conclusively, this modified method will contribute to freeze effectively the hamster oocytes for simplifing of the logical consideration of performing SPA and also to freeze the human and other animal oocytes.

  • PDF

$Ti-50.1at\%$ Ni합금의 변태거동에 미치는 시효처리의 영향(I) (The Effect of Ageing on the Transformation Behavior of $Ti-50.1at\%$ Ni Alloy(I))

  • 우흥식;박성범;강봉수;김성진
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2004
  • This study investigated the effects of aging on the transformation behavior of $Ti-50.1at\%$ Ni alloy by means of differential scanning calorimetry. It was found that aging in the temperature range of $350^{\circ}C\~550^{\circ}C$ induced complex transformation behavior, involving the R-phase and multiple-stage martensitic transformation. Usually aged Ni-rich NiTi alloys undergo martensitic transformation on cooling from high temperatures in two step : B2 to R and then R to Bl9'(normal behavior). But under certain ageing conditions, the transformation can also occur in three or more step(unusual multiple step behavior). In the present study we use differential seaming calorimetry(DSC) for a systematic investigation of the evolution of transformation behavior with ageing temperature and time.

액체로켓엔진의 연소가스와 액체질소 혼합에 의한 연소 가스 냉각 특성에 관한 연구 (Study on Cooling Characteristics of Mixed Gases with Hot Gas of Liquid Rocket Engine and Injected Liquid Nitrogen)

  • 전준수;유이상;김중일;김재호;고영성
    • 대한기계학회논문집B
    • /
    • 제36권10호
    • /
    • pp.1001-1009
    • /
    • 2012
  • 본 연구에서는 액체산소와 케로신을 추진제로 사용하는 액체로켓엔진의 연소 가스에 액체질소를 분사하여 연소 가스의 냉각 특성을 알아보고자 하였다. 일반적인 액체로켓엔진의 연소실 후단에 액체질소 분사기와 혼합용 연소실을 추가적으로 장착하였고, 혼합용 연소실 후단에 노즐을 연결하여 전체적인 시스템을 구성하였다. 연소실험은 안전을 고려하여 점화실험부터 순차적으로 수행하였으며, 최종적으로 20초 연소실험을 수행하였다. 그 결과 기존의 액체로켓엔진에 액체질소를 분사함으로써, 연소 가스의 온도를 저하시킬 수 있음을 확인하였다.

Development of stability maps for flashing-induced instability in a passive containment cooling system for iPOWER

  • Lim, Sang Gyu;No, Hee Cheon;Lee, Sang Won;Kim, Han Gon;Cheon, Jong;Lee, Jae Min;Ohk, Seung Min
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.37-50
    • /
    • 2020
  • A passive containment cooling system (PCCS) has been developed as advanced safety feature for innovative power reactor (iPOWER). Passive systems are inherently less stable than active systems and the PCCS encountered the flashing-induced instability previously identified. The objective of this study is to develop stability maps for flashing-induced instability using MARS (Multi-dimensional Analysis of Reactor Safety) code. Firstly, we conducted a series of sensitivity analysis to see the effects of time step size, nodalization, and alternative MARS user options on the onset of flashing-induced instability. The riser nodalization strongly affects the prediction of flashing in a long riser of the PCCS, while time step size and alternative user options do not. Based on the sensitivity analysis, a standard input and an analysis methodology were set up to develop the stability maps of PCCS. We found out that the calculated equilibrium quality at the exit of the riser as a stability boundary above 5 kW/㎡ was approximately 1.2%, which was in good agreement with Furuya's results. However, in case of a very low heat flux condition, the onset of instability occurred at the lower equilibrium quality. In addition, it was confirmed that inlet throttling reduces the unstable region.

Interfacial degradation of thermal barrier coatings in isothermal and cyclic oxidation test

  • Jeon, Seol;Lee, Heesoo;Choi, Youngkue;Shin, Hyun-Gyoo;Jeong, Young-Keun
    • 한국결정성장학회지
    • /
    • 제24권4호
    • /
    • pp.151-157
    • /
    • 2014
  • The degradation mechanisms of thermal barrier coatings (TBCs) were investigated in different thermal fatigue condition in terms of microstructural analyses. The isothermal and cyclic oxidation tests were conducted to atmospheric plasma sprayed-TBCs on NIMONIC 263 substrates. The delamination occurred by the oxide layer formation at the interface, the Ni/Cr-based oxide was formed after Al-based oxide layer grew up to ${\sim}10{\mu}m$ in the isothermal condition. In the cyclic oxidation with dwell time, the failure occurred earlier (500 hr) than in the isothermal oxidation (900 hr) at same temperature. The thickness of Al-based oxide layer of the delaminated specimen in the cyclic condition was ${\sim}4{\mu}m$ and the interfacial cracks were observed. The acoustic emission method revealed that the cracks generated during the cooling step. It was considered that the specimens were prevented from the formation of the Al-based oxide by cooling treatment, and the degradation mode in the cyclic test was dominantly interfacial cracking by the difference of thermal expansion coefficients of the coating layers.

30톤급 연소기의 연소시험을 위한 설비 개량 (Rocket Engine Test Facility Improvement for Hot firing test of a Combustor in the 30-tonf class)

  • 이광진;서성현;임병직;문일윤;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.313-317
    • /
    • 2005
  • The facility improvement for hot firing test of combustion chamber having thrust of 30-tonf class and chamber pressure of 60bara were performed at ReTF in KARI. The KSR-III main engine having combustion pressure of 13bara and thrust of 12.5tonf had been successfully tested in this facility. To increase the capability of the facility, the feeding and the trust measurement system have been modified. The modification of the feeding system plays also a role of ensuring the stability of propellant supply and two step ignition sequence of combustion chamber. The one-axis thrust measurement system of up to 60tons has been newly manufactured and installed in test stand and the water/kerosene supply lines with high pressure vessel of $4m^3$ and gas nitrogen vessel of $10m^3$ have been designed for regenerative cooling system. The results of cold flow test show that this facility has been successfully improved to satisfy the requirement for hot firing test of high performance combustor.

  • PDF