• Title/Summary/Keyword: Step Input Response

Search Result 149, Processing Time 0.023 seconds

Partial Image Retrieval Using an Efficient Pruning Method (효율적인 Pruning 기법을 이용한 부분 영상 검색)

  • 오석진;오상욱;김정림;문영식;설상훈
    • Journal of Broadcast Engineering
    • /
    • v.7 no.2
    • /
    • pp.145-152
    • /
    • 2002
  • As the number of digital images available to users is exponentially growing due to the rapid development of digital technology, content-based image retrieval (CBIR) has been one of the most active research areas. A variety of image retrieval methods have been proposed, where, given an input query image, the images that are similar to the input are retrieved from an image database based on low-level features such as colors and textures. However, most of the existing retrieval methods did not consider the case when an input query image is a part of a whole image in the database due to the high complexity involved in partial matching. In this paper, we present an efficient method for partial image matching by using the histogram distribution relationships between query image and whole image. The proposed approach consists of two steps: the first step prunes the search space and the second step performs block-based retrieval using partial image matching to rank images in candidate set. The experimental results demonstrate the feasibility of the proposed algorithm after assuming that the response tune of the system is very high while retrieving only by using partial image matching without Pruning the search space.

Transient State Improvement of Three-Phase ZSI with the Input Feedforward and Fuzzy PI Controller (입력 피드포워드와 퍼지 PI제어기를 갖는 3상 ZSI의 과도상태 개선)

  • WU, Yan-Jun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.359-360
    • /
    • 2012
  • This paper proposes a scheme of auto-tuning fuzzy PI controller and input voltage feed forward to control the output voltage of a three-phase Z-source inverter (ZSI). The proposed scheme adjusts the ts (Kp and Ki) in real time in order to find the most suitable Kp and Ki for PI controller and to simplify the controller design. The proposed scheme is verified the validity by experiment and co-simulation in PSIM and MATLAB/SIMULINK both load step change and input DC voltage variation in Z-source inverter, and has compared with the conventional PID control scheme. The experiment results involve of three-phase output voltage, Z-network capacitor voltage and dc-link peak voltage value. By those analysis and comparison, the availability of the proposed method in output voltage transient response quality improving has been verified. Compared with conventional PID method, the proposed method showed a more effective and robust control performance for coping with the severe disturbance conditions.

  • PDF

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

Modeling, Dynamic Analysis and Control Design of Full-Bridge LLC Resonant Converters with Sliding-Mode and PI Control Scheme

  • Zheng, Kai;Zhang, Guodong;Zhou, Dongfang;Li, Jianbing;Yin, Shaofeng
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.766-777
    • /
    • 2018
  • In this paper, a sliding mode and proportional plus integral (SM-PI) control combined with self-sustained phase shift modulation (SSPSM) for LLC resonant converters is presented. The proposed control scheme improves the transient response while preserving good steady-state performance. An averaged large signal model of an LLC converter with the ZVS modulation technique is developed for the SM control design. The sliding surface is obtained based on the input-output linearization concept. A system identification method is adopted to obtain the transform function of the LLC resonant converter, which is used to design the PI control. In order to reduce the inherent chattering problem in the steady state, the combined SM-PI control strategy is derived with fuzzy control, where the SM control is responsive during the transient state while the PI control prevails in the steady state. The combination of SSPSM and the SM-PI control provides ZVS operation, robustness and a fast transient response against step load variations. Simulation and experimental results validate the theoretical analysis and the attractive features of the proposed scheme.

A study on speed and Position of scanner Using PID controller (PID제어기를 이용한 스캐너의 속도 및 위치 제어)

  • Yeo, Bong-Hyeon;Chung, Yong-Chang;Hong, Chul-Ho;Kim, Jae-Wook;Kim, Mun-Su
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3178-3180
    • /
    • 2000
  • In this thesis, a controller which is appropriate for uses of scanner with small error and high speed response is proposed. Recently the application field of scanner is on increase. In case of applying to laser marking, the error of scanner has bad effect to quality. Also it can make difficulties in applying laser show that makes images, unless the high speed response is not realized. For these reasons, a controller that can adjust error and response is need. Because scanner must respond to step input that is put between a few millisecond and hundreds of microsecond with small revolution angle ranges, it is advantageous to have small inertia and large torque. First, the property of scanner is treated, and then using Op-amp and passive components and applying feedback compensation PID controller to design, the effects by controller coefficients are introduced.

  • PDF

Measurement strategy of a system parameters for the PI current control of the A.C. motor (교류 전동기의 PI 전류제어를 위한 시스템 파라미터 계측법)

  • Jung-Keyng Choi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.223-229
    • /
    • 2023
  • This Paper propose the method that measure main system parameters for PI(proportional-integral) current control of a.c. motor adopting the vector control technique. For current control, the PI control input is could be tuning by several selective methods. Among the several methods, the method that using the main system parameters, wire resistance and inductance, are frequently used. In this study, the technique to dissect and measure these two system parameters through the results of simple feedback control. This analytic measurement method is measuring parameters step by step dissecting the results of P control using simple proportional feedback gain about the unit step or multiple step reference command. This strategy is an real time analytic measurement method that calculate current control gains of torque component and flux component both for vector control of A.C. motor without introducing the further measurement circuits and complex measuring algorithms.

The Stability Improvement of Brushless DC Motor by Digital PI Control (디지털 PI제어에 의한 브러시리스 직류모터의 안정도 향상)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin;Im, Tae-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.38-46
    • /
    • 2000
  • This study have established proper mathematical equivalent model of Brushless DC (BLDC) motor and estimated the motor parameter by means of the back-emf measurement as being the step input to the controlled target BLDC motor. And the validity of proposed estimation method is confirmed by the test result of step response. As well, we have designed the reasonable digital controller as a consequence of the root locus method which is obtained from the open-loop transfer function of BLDC motor with hall sensor, and the determination of control gain for variable speed control. Here, revised Ziegler-Nichols tuning method is applied for the proper digital gain establishment, and the system stability is verified by the frequency domain analysis with Bode-plot and experimentation.

  • PDF

Digital Dynamic Compensation Methods of Rhodium Self-Powered Neutron Detector (로듐 자기출력형 중성자 계측기의 디지탈 동적 보상방법)

  • Auh, Geun-Sun
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.205-211
    • /
    • 1994
  • The best method is selected among the 3 digital dynamic compensation methods which are developed or applied for the Rhodium self-powered neutron detector. The three digital dynamic compensation methods are the existing Dominant Pol Tustin method of the COLSS(Core Operating Limit Supervisory System), the Direct Inversion method and Kalman Filter method. The Direct Inversion method is an improved method of D. Hoppe and R. Maletti and the Kalman Filter method is developed using the Kalman Filter. Response times of the compensated signals to achieve 90% of a step input are 28.1, 17.2 and 6.5 seconds respectively for the same noise gain telling that the Kalman Filter method is the best amens the 3 methods.

  • PDF

Multi-stage structural damage diagnosis method based on "energy-damage" theory

  • Yi, Ting-Hua;Li, Hong-Nan;Sun, Hong-Min
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.345-361
    • /
    • 2013
  • Locating and assessing the severity of damage in large or complex structures is one of the most challenging problems in the field of civil engineering. Considering that the wavelet packet transform (WPT) has the ability to clearly reflect the damage characteristics of structural response signals and the artificial neural network (ANN) is capable of learning in an unsupervised manner and of forming new classes when the structural exhibits change, this paper investigates a multi-stage structural damage diagnosis method by using the WPT and ANN based on "energy-damage" theory, in which, the wavelet packet component energies are first extracted to be damage sensitive feature and then adopted as input into an improved back propagation (BP) neural network model for damage diagnosis in a step by step mode. To validate the efficacy of the presented approach of the damage diagnosis, the benchmark structure of the American Society of Civil Engineers (ASCE) is employed in the case study. The results of damage diagnosis indicate that the method herein is computationally efficient and is able to detect the existence of different damage patterns in the simulated experiment where minor, moderate and severe damages corresponds to involving in the loss of stiffness on braces or the removal bracing in various combinations.

A Study of Step-by-step Countermeasures Model through Analysis of SQL Injection Attacks Code (공격코드 사례분석을 기반으로 한 SQL Injection에 대한 단계적 대응모델 연구)

  • Kim, Jeom-Goo;Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.12 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • SQL Injection techniques disclosed web hacking years passed, but these are classified the most dangerous attac ks. Recent web programming data for efficient storage and retrieval using a DBMS is essential. Mainly PHP, JSP, A SP, and scripting language used to interact with the DBMS. In this web environments application does not validate the client's invalid entry may cause abnormal SQL query. These unusual queries to bypass user authentication or da ta that is stored in the database can be exposed. SQL Injection vulnerability environment, an attacker can pass the web-based authentication using username and password and data stored in the database. Measures against SQL Inj ection on has been announced as a number of methods. But if you rely on any one method of many security hole ca n occur. The proposal of four levels leverage is composed with the source code, operational phases, database, server management side and the user input validation. This is a way to apply the measures in terms of why the accident preventive steps for creating a phased step-by-step response nodel, through the process of management measures, if applied, there is the possibility of SQL Injection attacks can be.