• Title/Summary/Keyword: Stem design

Search Result 301, Processing Time 0.022 seconds

Design and Development of STEM Program Based on Robotics Engineering Educational Model (로봇 엔지니어링 모델 기반 STEM프로그램 설계 및 개발)

  • Park, Jungho;Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.17 no.2
    • /
    • pp.177-189
    • /
    • 2013
  • According to a comparison study of international academic achievements, Korean students showed high academic achievements in science and mathematics, whereas their learning motivation appeared relatively low. Therefore, this work developed the robot-based STEM integrated education program reflecting an engineering class model. The title of the program is determined as 'animals' which are included in one section of the fourth grade science curriculum, are friendly to students, and are effective for robot application. Robot-based STEM program is consisted of three areas: robot education, subject-related course learning, and engineering education. The STEM program was reviewed by 14 teachers. The study result presented that regardless of knowledge of robot, most teachers gave positive response to program goal, composition of contents, application of robot.

  • PDF

Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA (인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화)

  • Park, Yong-Kuk;Kim, Jin-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

Comparison of Biomechanical Stability of Custom-made Hip Implants using Finite Element Analysis (스템 길이에 따른 환자맞춤 인공고관절의 역학적 안정성 비교)

  • Jun, Yongtae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.4
    • /
    • pp.426-432
    • /
    • 2016
  • Designing a morphologically well-fitted hip implant to a patient anatomy is desirable to improve surgical outcomes since a commercial ready-made hip implant may not well conform to the patient joint. In this study, biomechanical stability of patient-specific hip implants with two different stem lengths was compared and discussed using a 3D finite element analysis (FEA). The FEA results in this study showed that an increase in stem length brings about more the peaked von-Mises stress (PVMS) in the prosthesis and less in the femur. However the decrease in von-Mises stress in the femur causes stress shielding phenomenon that usually leads to considerable bone resorption. Although, in biomechanical stability point of view, this work recommends the use of smaller stems, the length of stem must be determined by considering both the von-Mises stress and the stress-shielding phenomenon.

Biomechanical Evaluation of Cement type hip Implants as Conditions of bone Cement and Variations of Stem Design (골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가)

  • Park, H.S.;Chun, H.J.;Youn, I.C.;Lee, M.K.;Choi, K.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.212-221
    • /
    • 2008
  • The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors. The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters. The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FE A using commercial stem model (Zimmer's V erSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.

Surface Roughness Effects of a Valve Stem on the Leakage Characteristics in LPG Automotive (LPG자동차에서 밸브스템 표면거칠기가 누유특성에 미치는 영향에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • This paper provides the effects on the leakage characteristics of the surface roughness of a valve stem in LPG automotive. The valve stem seal is to stop an oil leakage through a sealing gap between a valve stem and a valve stem seal. The sealing performance of two components is related to a leak safety and a long life of a valve stem and a valve stem seal. The experimental results show that the optimal surface roughness of a valve stem is to recommend as $0.4{\sim}0.5{\mu}m$ in a centerline average roughness, Ra and a uniformly distributed profile of the roughness. Basically the smooth surface and uniform profiles of the roughness may reduce an oil leakage between a valve stem and a valve stem seal.

  • PDF

In-depth Understanding of STEM Information Needs using FGI

  • Park, Minsoo
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.280-284
    • /
    • 2020
  • In the rapidly changing science and technology environment, an in-depth understanding of users of STEM information is an essential factor in designing a user-centered information system. The purpose of this study is to investigate and analyze in-depth the behaviors and needs of users who use STEM information. In this study, the needs of users for STEM information and STEM information sites are dealt with in depth using the FGI qualitative method. In addition, it includes the analysis results of grouping of similar sites according to various aspects of use of STEM information sites. As a result of grouping similar sites based on awareness and level of use,, they were grouped by domestic-international, paid-free, integrated-specific fields. As a result of grouping similar sites according to the purpose of use, they were grouped by domestic and international papers, research reports, and patents. As a result of grouping similar sites according to usage attributes, they were grouped by diversity, reliability, and specialization. As for the positions of similar sites perceived by users, Science Direct and PubMed showed high specialization and high quality, Google Scholar showed integration and popularity, and RISS showed four attributes evenly. Suggestions for information system design are discussed.

Expression of Chemokine Receptors Involved in Receptor-Mediated Endocytosis of Bone Marrow-Derived Stromal Stem Cells (골수 유래 기질 줄기세포의 탐식작용 매개성 케모카인 수용체 발현 연구)

  • Jeong, Young-Sin;Byun, Hyang-Min;Shin, Jee-Young;Kim, Jung-Mogg;Chung, Hyung-Min;Oh, Yu-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • To design gene deliver systems which can deliver higher amounts of genes into stem cells, we studied the expression of receptors involved in the receptor-mediated endocytosis of bone marrow stromal stem cells. Bone marrow was isolated from ICR mice, and bone marrow stromal stem cells were isolated based on their plastic adherence property. Several culture conditions were screened for effective and continuous culture of marrow stromal stem cells. MesenCult medium was finally used to cultivate marrow stromal stem cells in vitro. As candidate receptors, various chemokine receptors were studied. Both bone marrow cells ad marrow-derived stromal stem cells showed expression of CC chemokine receptors (CCR) and CXC chemokine receptors (CXCR). Marrow stromal stem cells showed higher expression of CCR5 ad CXCR4 chemokine receptors as compared to other types of chemokine receptors. Moreover, though the expression of chemokine receptors generally decreased in most chemokine receptors with the cultivaton of marrow stromal stem cells, CCR5 and CXCR4 chemokine receptors retained the higher level of receptor expressions over prolonged periods. These results suggest that the ligands exhibiting specific binding to CCR5 or CXCR4 might be used to modify gene delivery systems for increased levels of receptor-mediated gene delivery into stromal stem cells.

A Study on the contact surface of Stem and Bellows of Gate Valve in Nuclear Power Plants (원자력발전소 게이트밸브의 스템 - 벨로우즈 접촉면에 관한 연구)

  • Ko, Seok-Hoon;Shim, Dong-Hyouk;Kim, Dae-Youl;Choi, Myung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1044-1048
    • /
    • 2006
  • Nuclear power generation is very dangerous in occasion that skirt of structure by earthquake although it is high effective generation that can make a lot of energies with few raw material. when design, it must consider a lot of problems caused by an earthquake. The seismic analysis of the structure has been great concern in the engineering society with an effort to reduce the severe damages from an earthquake. So the earthquake resistant design is one of the crucial design procedures of a gate valve used in nuclear power generation. The gate valve which has the contact area between stem and bellows. Because of the contact area. The gate valve should be given high stress and frictional wear. In this thesis, Considering the gate valve which has some contact distance between stem and bellows. The gate valve which has some contact distance is analyzed by a commercial FEM code of Ansys and Then compared to the gate valve behavior which doesn't have contact distance.

  • PDF

Analysis of Thrust/Torque Signature of MOV (원자력 발전소 모터구동밸브의 쓰러스트/토크 신호 분석)

  • Ryu, Ho-Geun;Park, Seong-Keun;Kim, Dae-Woong
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.613-618
    • /
    • 2001
  • For the evaluation of operability of MOV(Motor Operated Valve), the precision prediction of thrust/torque acting on the valve is important. In this paper, the analytical prediction method of thrust/torque was proposed. The design basis stem thrust calculation typically considers the followings: Packing thrust, Stem rejection load, design basis differential pressure load. In general, test results show that temperature, pressure, fluid type, and differential pressure, independently and combination, all have an effect on the friction factor. The prediction results of thrust/torque are well agrement with dynamic test results.

  • PDF

Non Linear Finite Element Analyses of Ceramic/Ceramic Pairs of Total Hip Replacements Using High Trauma-Like Loads (고응력 외상에의한 고관절용 세라믹/세라믹 쌍의 비선형 유한요소법 분석)

  • Karyo, Daniel;Lee, Su-Wan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.179-180
    • /
    • 2005
  • Non linear finite element analyses were performed in various configurations of stem-ball head. High stresses were found for the cases when the stem tended to penetrate less into the ball head. An upgraded design of the cone may improve the loading of the ball head to resist trauma-like loading more effectively than manipulating the ball diameter. When the surgeon needs to use small ball heads (i.e. 22 mm), the use of zirconia seems to be appropriate also. After simulating a trauma like loading of the materials, it was found that the deepness of the cone to locate the stem is of major importance for the performance of the device. Further work, considering more sizes for the cone design should be performed in order to determine an optimal depth for the cone in relation to the diameter of the ball head. Also the simulation of contacts pairs including polyethylene and CoCr is important for further research.

  • PDF